Brand: Danfoss
Danfoss 137H3486 VACON 100 Flow Drive 261 A 132 kW IP21
Description
VACON 100 FLOW 261 A: a 132 kW IP21 drive for large pumps and fans
The 137H3486 is a VACON 100 FLOW of 261 A, Frame 09, in an IP21 / NEMA 1 housing for 380 to 500 V. At low overload it is rated 132 kW, which makes it a drive for large cooling-water pumps, boiler feed pumps and big air-handling fans.
The EMC category is C2 (commercial and industrial environment), better than the C4 of the 460 A module, which means that less external filtering is required in typical plant installations. The dimensions are 480 x 1150 x 365 mm and the net weight is 120 kg.
Technical specifications
| Parameter | Specification |
|---|---|
| Danfoss code number | 137H3486 |
| Type code | VACON0100-3L-0261-5-FLOW+SEBJ+DPAP+DLFI |
| Series | VACON 100 FLOW |
| Rated current | 261 Amp |
| Mains voltage | 380-500 Vac |
| Installation | DM Drive Module |
| Enclosure | IP21/NEMA1 |
| Frame | Frame 09 |
| Dimensions (W x H x D) | 480 x 1150 x 365 mm |
| Control panel | Graphical Keypad MK01 |
| EMC emission category | C2 Commercial&Industry Environ |
| Brake chopper | No dynamic braking device |
| Fieldbus (internal) | Std protocol,Modbus,N2,BacNet |
| B-slot board | F3,3 Relay board |
| E-slot board | BJ,STO, ATEX therm |
| Motor power, low overload | 132 kW |
| Continuous current, high / low overload | 261 A |
| Default motor frequency | 50 Hz def motor freq settings |
| Language pack | UK, DE, FI, SE, IT, FR lang |
| Net weight | 120 kg |
| EAN | = 5715253401980 |
Handling and cooling of a 120 kg drive
A drive of this class is usually placed on the floor of an electrical room next to the motor control centre. Provide a flat base, anchor the unit, and keep the free space on the top and sides specified in the operating guide. The heat loss is several kilowatts, so the room needs ventilation or air conditioning.
Cable entry is by a metric conduit plate (+QGLM), which allows armoured glands or conduit. Incoming and outgoing cables are heavy at 261 A; check the terminal capacity and bending radius before the cable is ordered.
Safety and communication options
As on the 12 A FLOW unit the E slot carries the BJ board with Safe Torque Off and an ATEX thermistor input, and the B slot holds a three-relay board. Standard protocols are Modbus, N2 and BACnet. There is no brake chopper, which is typical for pump duty.
The firmware language pack covers UK, DE, FI, SE, IT and FR; documentation is supplied as paper manuals. For an Ethernet fieldbus, ask us about the corresponding board code.
For large pumps the soft effects count: a variable-speed drive reduces the starting current, lowers mechanical stress on the shaft and the pipe, and offers speed control for flow. The size of the saving depends on the load profile, so measure it before you state it in a budget. Send us the pump curve and the duty cycle if you want a second opinion on the drive size.
A good enquiry for 137H3486 lists the code, the quantity, the site, the required documents and any approval certificates your inspector will ask for. Sending these together, rather than one by one, shortens the exchange and reduces the chance of a mismatch at delivery.
Ordering notes
Please confirm supply, motor nameplate, ambient temperature and options before ordering. Seven Star LLC is an independent supplier in Muscat and can quote 137H3486. The attached file is the Danfoss VACON 100 operating guide AQ298036140958; related drives are under AC drives.
Datasheets & Documents
- Operating Guide Danfoss VACON 100 Wall-mounted Drives Operating Guide AQ298036140958 (manufacturer, unaltered) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
Related products
Frequently Asked Questions
A VACON 100 FLOW 261 A drive: 380-500 V, IP21 / NEMA 1, Frame 09, 132 kW at low overload, EMC C2.
120 kg per the store entry.
The E-slot board listed in the store provides STO and an ATEX thermistor input.
No, no dynamic braking device is listed.
The Danfoss VACON 100 wall-mounted drives operating guide AQ298036140958.