Brand:

Hydac HNS 3226-2-0250-000 Magnetostrictive Level Switch

Description

A float-based level switch with 1 % accuracy for hydraulic tanks

The Hydac HNS 3226-2-0250-000 (HYDAC part number 924254) combines a magnetostrictive float sensor with a four-digit display and two PNP switching outputs. The float rides on a stainless steel rod and the instrument reads the float position with a repeatability of 1 percent of full scale, a tighter figure than the capacitive ENS 3000. The 3226 version has no temperature sensor and uses a G3/4 A DIN 3852 male thread.

HYDAC lists fluid level monitoring of hydraulic tanks as the main use. In this code the probe length is 250 mm (9.84 inches), which gives a measuring range of about 7 inches.

Technical specifications

Parameter Specification
HYDAC part number 924254
Model code HNS 3226-2-0250-000
Sensor type Magnetostrictive, float-based
Probe length 250 mm (9.84 in)
Measuring range 0 to 178 mm (7.01 in)
Mechanical connection G3/4 A DIN 3852, male; 30 N·m
Wetted parts Rod stainless steel 1.4571; float PP (0.6 kg/dm³); seal ring DIN 3869-27 FKM
Temperature sensor Not fitted in this version
Switching outputs 2 PNP transistor outputs, 1.2 A max. each; more than 100 million cycles
Repeatability / switching accuracy 1 % FS / 1 % FS (calm fluid)
Fluids Hydraulic oils, cooling lubricants
Max. tank pressure 43.5 psi; short-term 145 psi
Display 4-digit red LED, 7 mm digits
Supply voltage 9 to 35 V DC (18 to 35 V with analogue output)
Current consumption 150 mA max. without outputs
Electrical connection Male M12x1, 4-pole
Operating temperature -40 to +185 °F
Fluid temperature -40 to +248 °F
Storage temperature -40 to +212 °F
Protection class IP 67
Vibration / shock 7.5 mm (5 to 8.2 Hz) and 2.0 g (8.2 to 150 Hz) / 20 g (11 ms)
Weight 2.2 lb (about 1000 g)
Approvals as printed EN 61000-6-1/2/3/4 (CE)

When to pick the HNS over the ENS

The magnetostrictive principle follows the float position directly, so the reading does not depend on fluid conductivity or permittivity. That makes the HNS more predictable if the oil type changes. Different floats are offered, including stainless steel versions for aggressive media, and probe lengths from 9.84 to 98.4 inches are listed in the datasheet. The trade-off is a heavier unit of about 1 kg compared with the compact capacitive switch.

Order code

HNS 3 X 2 X – X – XXXX – 000: the first digit selects the temperature sensor (2 is without), the next 2 is the G3/4 A thread, the plug digit 6 gives M12x1 four-pole (8 five-pole, P eight-pole), then the output digit (2 is two switching outputs, 3 one switching plus one analogue, 5 two switching plus analogue, 8 four switching plus two analogue), and 0250 the probe length in mm. Datasheet E 18.061.2.0 (USA edition).

Check that the float diameter passes through the tank port, because the float is fitted over the rod before the unit is screwed in, and ensure the float cannot be fouled by a baffle or suction line.

A magnetostrictive probe tracks the float position along its length, so the 250 mm figure fixes the sensing length. Choose the length with the tank height in mind, leaving room for the head and the float travel, and confirm the float density for your liquid.

Documents and quotation

The datasheet is attached. Send the tank depth, the fluid and the output you need. Related: our level instrumentation range.

How the HNS 3226-2-0250-000 works

Magnetostrictive measurement uses a waveguide wire running inside the stainless steel probe tube. The float carries a permanent magnet. The electronics send a short current pulse along the waveguide; where the pulse’s magnetic field meets the float magnet, a torsional wave is created that travels back to the sensor head. The time between the pulse and the returning wave is proportional to the distance to the float, so the HNS 3226-2-0250-000 knows the float position, and therefore the fluid level, very precisely. The result is displayed on the four-digit LED display and compared with the programmed switching points.

Since only the float position is measured, the reading is independent of the electrical properties of the fluid, and foam above the liquid has little effect as long as the float is not lifted. Repeatability and switching point accuracy are both ±1 % FS, specified for calm, non-turbulent fluid.

Functions and outputs

  • Two independent PNP transistor switching outputs, programmable as N/O or N/C, each up to 1.2 A, with more than 100 million switching cycles.
  • Switching and switch-back points adjustable independently, so the hysteresis can be matched to the tank volume and the pump cycle.
  • Typical use of the two outputs: a minimum level alarm and a maximum level (overflow) alarm, or a pre-warning plus a shutdown signal.
  • Reverse-polarity protection of the supply, excess voltage, override and short-circuit protection are provided.

On the M12×1 4-pole plug of the HNS 3X26-2, pin 1 is +UB, pin 2 SP2, pin 3 0 V and pin 4 SP1.

HNS 3226-2-0250-000 selection & ordering guide

Option Choices in the HNS 3000 series
Temperature sensor 1 = with (semiconductor, –13 to +212 °F, ±3.0 °F); 2 = without (this model)
Mechanical connection 2 = G3/4 A DIN 3852 male
Electrical connection / output 6-2 = 4-pole, 2 switching outputs; 6-3 = 1 switching + 1 analogue; 8-5 = 5-pole, 2 switching + 1 analogue; P-8 = 8-pole, 4 switching + 2 analogue (with temperature sensor only)
Probe length 0250 = 9.84 in; 0280 = 11.02 in; 0370 = 14.57 in; 0410 = 16.14 in; 0520 = 20.47 in; 0730 = 28.74 in; other lengths on request
Measuring ranges 7.01; 8.19; 11.73; 13.31; 17.64; 25.90 in respectively

The analogue output, where chosen, is 4 to 20 mA (load 500 Ω) or 0 to 10 V (load 1 kΩ) and needs an 18 to 35 V DC supply. The USA edition of the datasheet lists the modification number 400 for inch-based units; the 000 ending on this model is the standard version. Our team can help confirm the correct ordering code if you are replacing an existing unit.

Installation & maintenance

  • Screw the unit into a G3/4 port on the tank cover with a suitable seal ring; the probe must hang vertically.
  • Fit the float in the correct orientation before installation and check that it moves freely over the full measuring range.
  • Keep the float away from return-line jets, suction strainers and baffles; use a splash guard from the HYDAC accessory range if the surface is turbulent.
  • Maximum tank pressure is 43.5 psi (145 psi for less than one minute).
  • During tank cleaning, remove deposits from the probe tube and float, and check that the float has not absorbed fluid or been damaged.

Typical applications in Oman & the GCC

The HNS 3000 is aimed primarily at fluid level monitoring of hydraulic tanks. Typical installations include hydraulic power units on industrial presses, steel and aluminium plant hydraulics, cooling lubricant tanks on machine tools, and power packs on mobile and marine equipment. With an operating range of –40 to +185 °F and fluid temperatures up to +248 °F, the switch suits hot reservoirs often found on plants across Oman and the GCC.

Why source from Seven Star LLC

Seven Star LLC supplies HYDAC level switches, accessories and connectors across Oman and the GCC. Request a quote for the HNS 3226-2-0250-000 and send your tank height and fluid details.

Datasheets & Documents
  • PDF Datasheet Hydac HNS 3000 electronic level switch datasheet (E 18.061.2.0, USA edition) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

Frequently Asked Questions

What is the probe length of the HNS 3226-2-0250-000?
250 mm (9.84 inches), with a measuring range of 0 to 178 mm.
How accurate is the switching point?
Within 1 % of full scale for calm fluid.
Which thread does it have?
A G3/4 A male thread to DIN 3852.
Does it include a temperature sensor?
No. The digit 2 after the series number means without temperature sensor.
Which fluids is it intended for?
Hydraulic oils and cooling lubricants, with other fluids on request.