Sensus WPV-MS 150 Compound Water Meter DN 150

Description

The Sensus WPV-MS 150 is a DN 150 compound water meter for cold water, with a main meter for high flows and a by-pass meter for very low flows. It has MID pattern approval, needs no straight pipe upstream or downstream because of its integrated flow straightener, and uses a spring-loaded change-over valve with low head loss and extended lifetime. The sheet describes it as ideal for fire service pipes, and for installations with an extremely wide spread of flow rates.

Technical specifications

Parameter Specification
Product Sensus WPV-MS 150 compound water meter, cold water up to 50 degC (T30 class), DN 150
Pattern approval MID 2014/32/EU annex MI001, DE-14-MI001-PTB002; marking CE M-XX 0102; temperature class T30
Nominal diameter and pressure DN 150; PN 16
Installation Horizontal; no straight upstream or downstream pipe needed (integrated flow straightener, U0D0)
Meter construction Main turbine-type meter with cast iron body; by-pass rotary piston meter RK-MS HRI Q3 16 (brass body, DN 40); plastic measuring elements and rotors; spring-loaded change-over valve of plastic and stainless steel
Protection IP68, can be submerged; copper/glass register on the by-pass meter; powder coating for corrosion protection
Medium Cold water, materials resistant up to 50 degC
Pulse values, main meter HRI-Mei 0.1, 1 or 10 m3; OD 01: 0.01 m3; OD 03: 0.1 m3; with encoder register HRI 1 or 10 m3
Pulse values, by-pass meter HRI-Mei 0.01, 0.1 or 1 m3; OD 01: 0.001 m3; OD 03: 0.01 m3; with encoder register HRI 0.1 or 1 m3
Options Pulse and data interface HRI-Mei and pulsers OD on main and by-pass meters; overall length per DIN with spool piece; ER56 encoder register
Order example WPV-MS DN 150 T30 16 (type, nominal diameter, working temperature, working pressure, flange drilling EN 1092 PN 16, with or without spool piece)

Performance data

Parameter According to MID pattern approval According to manufacturer data
Maximum peak flow Q4 315 m3/h Qs 600 m3/h
Continuous flow Q3 250 m3/h Q3′ 400 m3/h
Transitional flow Q2 (m3/h) 0.16 0.15
Minimum flow Q1 (m3/h) 0.1 0.035
Change-over flow (increasing / decreasing) Qx2 8.3 / Qx1 4.7 m3/h –

Dimensions and weight

Dimension Value
Overall length L1 500 mm
Length with spool piece L 1000 +/-40 mm
Height H / to axis h / dismantling g 177 / 135 / 356 mm
Width B / b approx. 275 / 145 mm
Weight meter / spool piece 60 kg / 32 kg

Main meter and by-pass meter

The main meter is cast iron with a plastic measuring element and rotor, while the by-pass meter is specified as a rotary piston meter, type RK-MS HRI, in a brass body with a copper and glass register in protection class IP68. At low flow all water passes through the by-pass, and as flow rises past the change-over flow (8.3 m3/h increasing, 4.7 m3/h decreasing under the MID pattern approval) the valve opens to the main meter. This gives a minimum flow Q1 of 0.1 m3/h under MID and, by the manufacturer’s values, 0.035 m3/h, which makes it suitable for measuring small flows for leakage detection while still passing high flows. Both meters can be fitted with HRI-Mei or OD pulse interfaces, or an ER56 encoder register.

Selection and installation

Check the two performance tables carefully: the MID values (Q3 250 m3/h) are the legally approved ones, while the manufacturer values (continuous flow 400 m3/h and peak flow Qs 600 m3/h) describe the hydraulic capacity. The meter must be installed horizontally and the standard overall length is 500 mm, with a version with a spool piece of about 1000 mm for fitting in a line where a longer length is needed. Weight is 60 kg for the meter and 32 kg for the spool piece, so lifting equipment is likely to be required. Materials are resistant up to 50 degC, the temperature class is T30, and the meter can be submerged. Confirm the flange drilling, pulse values and approvals required by the supply authority.

Documents and quotation

The linked file is the four-page Sensus WPV-MS 150 data sheet LB 1720 INT. Before ordering confirm the flange drilling, the use of the spool piece, the pulse or encoder options, the temperature class and the approvals needed. See also related flowmeters. Seven Star LLC, an independent supplier in Muscat, will prepare a quotation from your project requirements.

Datasheets & Documents
  • PDF Datasheet Sensus WPV-MS 150 data sheet (LB 1720 INT) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Sensus is a maker of water, gas and electricity meters and the networks that read them, headquartered in Raleigh, North Carolina. Xylem agreed to buy Sensus in August 2016 for about 1.7 billion US dollars, adding smart metering and advanced metering infrastructure to its water technology business. At the time Sensus had more than 80 million metering devices installed worldwide.

Seven Star LLC is an independent supplier in Muscat. We list Sensus meters backed by the manufacturer data sheets for utilities, developers and facility teams in Oman and the GCC.

Sensus company profile

Headquarters Raleigh, North Carolina, USA
Ownership Xylem, after an agreement announced in August 2016
Deal value About 1.7 billion US dollars
Installed base More than 80 million metering devices worldwide (2016)
Product families iPERL electromagnetic and Cordonel ultrasonic static water meters, 620 volumetric meters, bulk and woltman meters, gas and electricity meters, FlexNet AMI communication network

Sensus product series

Static meters include the iPERL electromagnetic water meter and the iPERL+ smart meter (documented in US units and standards), and the Cordonel ultrasonic meter for DN 40 to 200. Residential and sub-metering meters include the 620 volumetric meter with dry dial, the 640 with electronic register, the 420 and 420PC multijet meters and the DomoJet single jet meter.

For larger flows there are the WP-Dynamic Woltmann turbine meter for DN 40 to 300, the WPV-MS 150 compound meter and the MeiStream Plus bulk meter for DN 40 to 150.

Where Sensus meters are used

Utility billing for homes and buildings, bulk supply and district metering, sub-metering in compounds and towers, and irrigation and industrial water metering.

Sensus products we list

Family Examples
Flowmeters 420 and 420PC Multijet Water Meter DN 15…, 620 Volumetric Water Meter Dry Dial DN 1…, 640 Volumetric Water Meter with Electron…, Cordonel Static Ultrasonic Water Meter D…, DomoJet Single Jet Water Meter DN 15-20, iPERL Static Electromagnetic Water Meter, iPERL+ Smart Water Meter, MeiStream Plus Class C Bulk Water Meter… and 2 more

Ordering Sensus meters: what we need

Send the DN, connection or flange drilling, lay length, ratio, temperature class, the approvals your utility requires (MID, OIML R49, ISO 4064 or potable water approvals) and the radio or register option.

Facts checked against Xylem's 2016 announcement and financial press, October 2026.

Frequently Asked Questions

What is a compound meter?
A meter that combines a main meter for high flows with a by-pass meter for low flows; the WPV-MS 150 changes over with a spring-loaded valve.
Does it need straight pipe sections?
No. The integrated flow straightener means no straight upstream or downstream pipe is required.
What size is the WPV-MS 150?
DN 150 at PN 16.
Can it be used on fire service lines?
The data sheet describes it as ideal for fire service pipes.
What temperature class does it have?
T30 under the MID pattern approval, with materials resistant to 50 degC.