Brand:

DeFelsko PosiTector RTR H Replica Tape Reader

Description

Reading replica tape electronically for blast profile

The DeFelsko PosiTector RTR H is a digital micrometer that reads Testex Press-O-Film replica tape and converts the burnished tape thickness to a surface profile height for blasted steel and textured coatings. The operator cleans the site with putty, selects the tape grade, burnishes a piece of tape onto the surface with the burnishing tool, then inserts the compressed tape between the measurement anvils. The gage applies the conversion factor for the selected tape grade and subtracts the 50 micrometre (2 mil) backing thickness automatically. The method follows ASTM D4417, ISO 8503-4 and NACE SP0287, and the tape leaves a permanent record of the surface.

Technical specifications

Parameter Specification
Peak height (HL) measurement range 20-115 micrometres (0.8-4.5 mils)
Accuracy +/-5 micrometres (+/-0.2 mils)
Resolution 1 micrometre (0.1 mil)
Anvil diameter 6.35 mm (0.25 in.)
Anvil pressure 1.1 N (110 gram-force)
Gage body 127 x 66 x 25.4 mm (5 x 2.6 x 1 in.), 137 g (4.9 oz) without batteries; 2.8 in. colour touchscreen; IP65-rated enclosure
Memory Standard: 1,000 readings per probe; Advanced: 250,000 readings in up to 1,000 batches; WiFi and Bluetooth 4.0 on Advanced
Standards listed ASTM D4417 Method C, ISO 8503-5, NACE SP0287, SSPC-PA 17, SSPC-SP5, SP6, SP10, SP11-87T and others
Calibration Long-form Certificate of Calibration traceable to PTB; two-year warranty on body and probe

Ordering codes and replica tape grades

The ordering guide lists RTR H1 as a gage with a Standard body and RTR H3 as a gage with an Advanced body, each with the same micrometer probe specification. Standard bodies include storage of 1,000 readings per probe; Advanced bodies store 250,000 readings in up to 1,000 batches, add live graphing and a touchscreen keyboard, and include WiFi and Bluetooth. The datasheet states that every gage comes complete with a high-accuracy burnishing tool, five cleaning cards, check shims, surface cleaning putty, a rubber holster, wrist strap, three AAA batteries, instructions, a nylon carrying case with shoulder strap, a lens shield and a long-form Certificate of Calibration. The replica tape itself is a consumable ordered separately.

The instruction manual selects the tape grade from the expected profile height and gives the order codes below. If a reading falls outside the range of the grade used, the manual says to disregard it and measure again with the correct grade. A 2024 study quoted in the manual gives accuracy of +/-8 micrometres (0.3 mils) for Coarse and X-Coarse tape and +/-10 micrometres (0.4 mils) for X-Coarse Plus, when the stated procedure and the high-accuracy burnishing tool are used and at least two replicas are measured per location.

Tape grade Profile range Order code
Coarse Minus 13-25 micrometres (0.5-1.0 mil) RTCMIN
Coarse 20-50 micrometres (0.8-2.0 mils) RTC
X-Coarse 40-115 micrometres (1.5-4.5 mils) RTXC
X-Coarse Plus 100-150 micrometres (4.0-6.0 mils) RTXCPLUS

Replica tape gives a record that can be attached to a report and measures on surfaces where a depth micrometer cannot sit stably. A depth micrometer such as the

DeFelsko PosiTector SPG.

reads directly with no consumable and measures faster. Both are accepted methods in ASTM D4417, so the choice usually follows the specification, the surface geometry and the reporting requirement. Related instruments on this site include the Elcometer 224 digital surface profile gauge; see all portable test and measurement instruments.

How the DeFelsko PosiTector RTR H works

A foam layer on the replica tape is pressed into the blasted surface and takes the shape of the peaks and valleys. The tape is then placed between two small anvils. The gage measures the thickness of the pressed tape and takes off the backing thickness. The result is the peak height of the profile, shown in micrometres or mils.

Where the PosiTector RTR H is used

  • Blasted steel before coating
  • Tank and pipe preparation
  • Bridge and structure painting
  • Shipyard work
  • Coating inspection records

Selection checklist for the PosiTector RTR H

  • Standard or Advanced body
  • Profile range in the job spec
  • Replica tape grade
  • Memory and batch needs
  • WiFi or Bluetooth reports
  • Number of readings per site
  • Spare burnishing tools
  • Carrying case

Installation, commissioning and maintenance notes for the PosiTector RTR H

Clean the test site with the putty. Burnish the tape firmly onto the surface and peel it off. Place the tape between the anvils and read the value. Check the gage with the check shims before use. Keep the anvils clean and store the gage in its case.

Requesting a quotation for the DeFelsko PosiTector RTR H

Please send the body type, the profile range and the quantity. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.

PosiTector RTR H range

The peak height range is 20 to 115 micrometres.

PosiTector RTR H accuracy

The accuracy is plus or minus 5 micrometres.

PosiTector RTR H resolution

The resolution is 1 micrometre.

PosiTector RTR H anvils

The anvil diameter is 6.35 mm and the anvil pressure is 1.1 N.

PosiTector RTR H display

The gage has a 2.8 inch colour touchscreen.

PosiTector RTR H memory

The Standard body keeps 1,000 readings and the Advanced body keeps 250,000.

PosiTector RTR H connectivity

The Advanced body has WiFi and Bluetooth.

PosiTector RTR H enclosure

The enclosure is IP65 and the body weighs 137 g without batteries.

PosiTector RTR H kit contents

The kit has a burnishing tool, check shims, cleaning putty and a nylon case.

PosiTector RTR H ordering codes

RTR H1 has the Standard body and RTR H3 has the Advanced body.

Inspection records for the PosiTector RTR H

Record the site, the tape grade and the readings for each test.

Choosing the right PosiTector RTR H body

Choose the Advanced body when the job needs batches and wireless reports.

Documents and quotation

The attached DeFelsko datasheet describes the models. Please confirm before ordering the Standard or Advanced version, the replica tape grades you need and the procedure you inspect to, and send them with your enquiry so the code can be checked against the manufacturer documentation.

Datasheets & Documents
  • PDF Datasheet DeFelsko PosiTector RTR datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

DeFelsko is an American manufacturer of hand-held coating inspection instruments, founded in 1965 in Ogdensburg, New York, by Frank Koch, a German-trained tool and die maker. It began by importing inspection instruments, then moved into manufacturing with the PosiTest mechanical pull-off gauge and the PosiTector series. DeFelsko remains family-run and builds its gauges in Ogdensburg.

Seven Star LLC is an independent supplier in Muscat. We list DeFelsko instruments for coating inspectors and painting contractors in Oman and the GCC.

DeFelsko company profile

Founded 1965, Ogdensburg, New York, USA, by Frank Koch
Headquarters Ogdensburg, New York
Ownership Family-run; David Beamish became president after Frank Koch's death in 2011
Innovations Hand-held ultrasonic coating thickness gauges, auto-switching ferrous/non-ferrous gauges and self-aligning adhesion testers
Product families PosiTector 6000 coating thickness gauges, PosiTector 200 ultrasonic coating gauges, PosiTector SPG and RTR surface profile gauges, PosiTector DPM dew point meters, PosiTest AT adhesion testers, PosiTector UTG wall thickness gauges

Milestones

  • 1965: Frank Koch founds DeFelsko in Ogdensburg.
  • 2011: David Beamish becomes president.

DeFelsko product series

PosiTector gauges share one body with interchangeable probes: the PosiTector 6000 coating thickness gage for metal substrates, the PosiTector 200 ultrasonic coating thickness gage for non-metal substrates, the PosiTector UTG ultrasonic wall thickness gage, the PosiTector SPG surface profile gage, the PosiTector RTR H replica tape reader, the PosiTector DPM dew point meter and the PosiTector SST soluble salt tester.

PosiTest instruments include the PosiTest AT-A automatic pull-off adhesion tester and the PosiTest HHD high voltage holiday detector.

Magnetic probes measure coatings on steel, eddy current probes measure coatings on non-ferrous metals, and the ultrasonic PosiTector 200 measures coatings on concrete, wood and plastics. All PosiTector probes plug into one gauge body, so an inspector can carry one instrument with several probes.

Where DeFelsko instruments are used

Surface preparation and coating inspection of pipelines, tanks, structural steel, ships and concrete, to standards such as ISO 8501, ISO 2808, ASTM D4417 and SSPC-PA 2.

DeFelsko products we list

Family Examples
Portable Test & Measurement PosiTector DPM Dew Point Meter, PosiTector RTR H Replica Tape Reader, PosiTector SPG Surface Profile Gage, PosiTest AT-A Automatic Pull-Off Adhesio…, PosiTest HHD High Voltage Holiday Detector
Specialty Thickness Gauges PosiTector 200 Ultrasonic Coating Thickn…, PosiTector 6000 Coating Thickness Gage
Corrosion Thickness Gauges PosiTector UTG Ultrasonic Wall Thickness…

Ordering DeFelsko instruments: what we need

Send the gauge body (Standard or Advanced) and probe type, the substrate and coating, thickness range, and whether calibration certificates and data software are needed.

Facts checked against trade press profiles of DeFelsko and its founder, October 2026.

FAQ

Questions about the DeFelsko PosiTector RTR H Replica Tape Reader

Answers from our engineering team on installation, compatibility and integration.

01What does the PosiTector RTR H read?
Testex Press-O-Film replica tape, converting the tape thickness to a peak height surface profile.
02What is the measurement range?
20 to 115 micrometres (0.8 to 4.5 mils) of peak height.
03Does it subtract the tape backing?
Yes, selecting the tape grade applies the conversion factor and subtracts the 50 micrometre (2 mil) backing thickness.
04Which standards does it conform to?
The datasheet lists ASTM D4417 Method C, ISO 8503-5, NACE SP0287 and SSPC-PA 17, among others.
05What is the difference between RTR H1 and RTR H3?
H1 has a Standard body and H3 an Advanced body with larger memory, graphing, WiFi and Bluetooth.