Brand:

Magnetrol Echotel 961/962 Ultrasonic Level Switch

Description

Overview

The Magnetrol Echotel 961/962 ultrasonic level switches were developed for overfill protection, high and low level alarms and pump control where reliability is the main requirement. The Model 961 is a single-point switch, while the Model 962 has two sensing gaps for control of pumps in auto fill or auto empty mode. Magnetrol designed both with a self-test function that checks the electronics, the transducer and the piezoelectric crystals, and they are suitable for use in Safety Integrity Level (SIL) 2 loops according to the datasheet.

Seven Star LLC supplies the Magnetrol Echotel 961/962 to refineries, petrochemical and chemical plants, power stations and water utilities across the Sultanate of Oman and the GCC. Our Muscat engineers help select transducer material, insertion length and electronics, and prepare an offer that includes the documentation that safety engineers need.

Operating Principle

The Magnetrol Echotel 961/962 uses ultrasonic energy to detect the presence or absence of liquid in a gap at the transducer tip. A transmit crystal converts the supplied voltage into a 2 MHz ultrasonic signal, and a receive crystal on the other side of the gap converts it back to an electrical signal. When liquid fills the gap the sound crosses easily, and the electronics indicate liquid. When the gap is dry the signal is attenuated and the receive crystal sees nothing, so the switch indicates dry.

Magnetrol uses pulsed signal technology rather than a continuous wave. The transmitter produces powerful bursts of ultrasonic energy that pass through aerated liquids, suspended solids and viscous media, and the burst structure gives excellent immunity to electrical noise. Because the principle does not depend on density, dielectric or conductivity, the Magnetrol Echotel 961/962 does not need to be configured for different media, which makes spares and commissioning simpler. An adjustable time delay of half to ten seconds lets the switch ignore waves and splashing.

Engineering Design of the Magnetrol Echotel 961/962

The Magnetrol Echotel 961/962 has a tip-sensitive lower gap on both models that allows liquid level to be measured to within a quarter inch of the vessel bottom, and the Model 962 adds a rigid flow-through upper gap with a stiffening tube that allows separations of up to 127 inches (322 cm). Transducers are offered in 316 stainless steel, Hastelloy C-276, Monel, Kynar and CPVC, covering temperatures from -40 to +325 °F (-40 to +163 °C) for the metal designs, and a cryogenic option down to -110 °F on selected models.

Electronics can be integral or remote mounted. Relay versions run on 12 to 28.4 VDC or 100 to 265 VAC, with power consumption below 3 watts, and loop-powered versions use 12 to 28.4 VDC with current shift output. A malfunction indication is separate from the level signal, and a red LED, an optional manual self-test and a DIP switch for auto fill or auto empty modes on the Model 962 help service personnel. FM, ATEX and IEC approvals are listed in the datasheet.

Key Features

The Magnetrol Echotel 961/962 offers dependable point level detection with extensive diagnostics. Key features of the Magnetrol Echotel 961/962 include:

  • Single-point (961) and dual-point (962) liquid level measurement with the same family of electronics.
  • No calibration required, and performance independent of liquid type and density.
  • Pulsed signal technology for aerated, viscous and noisy environments.
  • Advanced self-test that continuously checks the electronics, transducer and crystals, and generates a malfunction output.
  • Adjustable time delay of 0.5 to 10 seconds for turbulent or aerated liquids.
  • Relay output or mA current shift output, each with separate malfunction indication.
  • Integral or remote mount electronics, with transducer materials from 316 stainless steel to CPVC.
  • Suitable for SIL 1 and SIL 2 loops, with FMEDA data and SIL manual 51-650 available.

Industrial Applications

The Magnetrol Echotel 961/962 is used for overfill protection, high and low level alarms, seal pot level, pump protection and control, chemical tanks, fill lines and level in vessels with spray balls. In Oman, storage tanks in petrochemical complexes, chemical dosing tanks for water treatment, fuel oil day tanks in power stations and cryogenic liquids at gas plants are good fits for a switch that works without calibration. Where a vibrating fork is preferred, buyers may also consider the ABB RS85, while for continuous indication alongside the switch, a Tecfluid LT-R153 magnetic level transmitter can be quoted.

Seven Star LLC supplies the Magnetrol Echotel 961/962 on request, with engineering support in Muscat, for projects in the Sohar and Salalah economic zones. For a plant that wants both point protection and continuous measurement on the same vessel, the Magnetrol Echotel 961/962 pairs well with the Magnetrol Eclipse 706 guided wave radar, so that an independent high-high alarm backs up the process transmitter.

Technical Specifications

The table lists the main data of the Magnetrol Echotel 961/962 from the Magnetrol datasheet. The material code selects the temperature and pressure ratings.

Parameter Specification
Model Magnetrol Echotel 961 single point and 962 dual point ultrasonic level switch
Measuring principle Pulsed ultrasonic signal, 2 MHz, contact transducer gap
Supply (relay) 12 to 28.4 VDC or 100 to 265 VAC, 50/60 Hz; under 3 W
Supply (loop) 12 to 28.4 VDC; current shift 8 mA normal, 16 mA alarm; fault 3.6 or 22 mA
Relays 961: one DPDT level, one SPDT malfunction; 962: two SPDT level, one SPDT malfunction
Transducer temperature -40 to +325 °F (-40 to +163 °C) for 316 SS, Hastelloy C-276 and Monel
Maximum pressure Up to 2000 psi (138 bar) in 316 SS and Hastelloy C-276 short lengths
Actuation length 1 to 130 in (3 to 330 cm) depending on model and material
Time delay 0.5 to 10 seconds adjustable
Ambient temperature -40 to +160 °F (-40 to +70 °C)
Functional safety Suitable for SIL 1 and SIL 2 loops
Approvals FM, ATEX and IEC

Request a Quote for Magnetrol Echotel 961/962

To order the Magnetrol Echotel 961/962, send Seven Star LLC the liquid, vessel connection, required insertion or actuation length, supply voltage, output type and approval requirement. Our instrumentation division in Muscat will select the model and transducer material, check the safety documentation you need and provide the Magnetrol datasheet with the quotation. Seven Star LLC supplies Magnetrol equipment with manufacturer documentation and local engineering support across Oman and the GCC, so submit your RFQ for the Magnetrol Echotel 961/962 today.

Datasheets & Documents
  • PDF Datasheet Magnetrol Echotel 961 and 962 Ultrasonic Level Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol Echotel 961/962 Ultrasonic Level Switch

Answers from our engineering team on installation, compatibility and integration.

01How does the Magnetrol Echotel 961/962 detect liquid?
The Magnetrol Echotel 961/962 sends a 2 MHz ultrasonic pulse between two piezoelectric crystals separated by a gap in the transducer tip. When liquid fills the gap the signal is transmitted and detected, and when the gap is dry the signal is attenuated and the switch changes state.
02Does the Magnetrol Echotel 961/962 need calibration for different liquids?
No. The datasheet lists no calibration required and performance independent of liquid type and properties such as density. Pulsed signal technology also handles aeration, suspended solids and high viscosity, without the media-specific settings that tuning fork switches need.
03What is the difference between the Magnetrol Echotel 961 and 962?
The 961 is a single-point switch with a tip-sensitive transducer for high or low level alarms, while the 962 is a dual-point switch with a tip-sensitive lower gap and a flow-through upper gap, which allows level control and auto fill or auto empty pump control with separation up to 127 inches.
04What outputs and safety ratings does the Magnetrol Echotel 961/962 offer?
Relay versions use a DPDT level relay on the 961 and two SPDT level relays on the 962, each with a separate malfunction relay. Loop-powered versions use 8 and 16 mA current shift, with 3.6 or 22 mA for faults. The switches undergo FMEDA assessment and are suitable for SIL 1 and SIL 2 loops.
05Does Seven Star LLC supply the Magnetrol Echotel 961/962 in Oman?
Seven Star LLC supplies the Magnetrol Echotel 961/962 with engineering support in Muscat for Oman and the GCC. Provide the liquid, vessel connection, insertion length, power supply and approvals and we will quote the correct transducer and electronics.