Brand: Palmer Wahl
Palmer Wahl DSPG Digital Pressure Gauge Data Logger
Description
A digital pressure gauge with data logger, alarms and optional transmitter
The Palmer Wahl Digi-Stem DSPG is a digital process pressure gauge in an IP68 stainless steel housing, designed and built in Asheville, North Carolina. It shows the real-time pressure on a 0.9 inch five-digit display and the maximum, minimum, average, delta pressure, alarm settings or internal electronics temperature on a 0.4 inch secondary display. Two accuracy options are offered, and an optional switch and transmitter module can run at the same time as the display and the logger.
The datasheet lists 12 continuous self-checks of the electronics and the sensor, including pressure above or below range, sensor disconnected or shorted, ambient temperature out of limits, unstable signal, power supply and memory problems. Any out-of-tolerance condition is reported by an error code.
Features
- Two accuracy options: precision accuracy plus or minus 0.1 percent of full scale at 23 C, or reference accuracy plus or minus 0.05 percent of full scale from 0 to 50 C with an included 9-point NIST Certificate of Conformance.
- Pressure range -15 to 15,000 psi depending on pressure type: relative gauge, absolute, compound, vacuum and barometric ranges.
- Eleven pressure units: psi, bar, mbar, Pa, kPa, MPa, kg/cm2, inH2O, mmH2O, inHg and mmHg.
- Built-in data logger for 1,000,000 time-stamped readings, with the Wahl data logger software on a USB flash drive for download to an MS Excel file.
- Visual alarm backlight: red for high alarm, blue for low alarm and green for normal operation, all adjustable.
- Bottom connection or the adjustable angle mounting option, which the datasheet calls an industry first for digital pressure gauges.
- Optional built-in switch and transmitter, user selectable 4 to 20 mA or 0 to 5 V, powered by a customer-supplied 24 V DC loop supply.
DSPG specifications
| Parameter | Specification |
|---|---|
| Case | Stainless steel case, polycarbonate H-frame window |
| Meter range | -15 to 15,000 psi depending on pressure type |
| Precision accuracy | Plus or minus 0.1 percent full scale at 23 C |
| Reference accuracy | Plus or minus 0.05 percent full scale at 0 to 50 C with 9-point NIST certificate (0, 50 and 100 percent at 0, 23 and 50 C) |
| Operating environment | -4 to 158 F (-20 to 70 C); 10 to 100 percent RH non-condensing |
| Storage | -25 to 85 C (-13 to 185 F) |
| Battery | One C-size 3.6 V lithium thionyl chloride, or one AA 3.6 V; 4 years on C at 1 s update, 1.2 years on AA |
| Display | 0.9 inch 5-digit primary readable to 30 ft; 0.4 inch 5-digit secondary; 20-step range bar |
| Update rates | 1 s default, 2 s, 5 s |
| Data logger | 1,000,000 readings with date and time; intervals 10 s default, 20, 30, 60, 120, 300 or 600 s |
| Digital output | Wahl Protocol; MS Excel file via Wahl software (Windows 8, 10, 11) |
| Analog output | 4 to 20 mA or 0 to 5 V; transmitter accuracy 0.1 percent plus 0.005 percent span; switch 0.1 percent plus 0.1 percent span |
| Switch | Two programmable pressure points for high and low on or off |
| Protection | NEMA 6P, IP68, survives submersion to 1 meter |
| Dimensions and weight | 5.3 x 4.3 x 2.7 in (135 x 109 x 69 mm), 2.0 lb (1 kg) |
| Datasheet date | May 2026 |
Mounting, ports and what is included
Bottom connected units use a round M12-8 analog connector for the optional transmitter and switch; adjustable angle units use a hex connector, and an M12-4 digital port serves the data logger. The datasheet states that the package includes a quick start guide, the data logger software on a USB flash drive, a custom-fit foam-lined box suitable for returning the unit for calibration, and the user manual as a download.
When the unit is powered by battery and an alarm condition is met, the matching backlight lights for 1 second and the HAL or LAL icon keeps blinking until the alarm clears. When externally loop powered, the alarm backlight stays on, and the green backlight is continuous in normal operation.
Selection and installation
- Choose reference accuracy if you need the 9-point NIST certificate at three temperatures, and precision accuracy for general process work.
- State the pressure type (gauge, absolute, compound, vacuum or barometric) and the full-scale range when you enquire; the datasheet leaves port size and range to the build-to-order process.
- Add the transmitter and switch module only if you can provide a 24 V DC loop supply; the datasheet requires it, with a battery kept for display backup.
- Pick bottom connection for a fixed pipe tap and adjustable angle when the gauge must be read from an awkward position.
Applications in Oman and the GCC
The datasheet lists processing plants, chemical and petrochemical, oil and gas, field calibration, mobile calibration labs, calibration service companies, gauge repair facilities, test benches and OEM use. For the Gulf this means a rugged, sealed digital gauge for plant maintenance teams, instrument workshops and calibration laboratories that need a logged record.
Selection and installation notes
A digital process pressure gauge is selected from the pressure range, the process connection and the wetted material. Check that the enclosure rating suits the area, set the alarms and the logging interval at commissioning, protect the gauge from pulsation with a snubber where needed and replace the battery on schedule. Download the log before the memory is full.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Related items and documents
See more pressure instruments in our range. The datasheet is attached; Seven Star LLC can quote the range and options.
Related Palmer Wahl products: Palmer Wahl DST600 DST640 Digi-Stem RTD Thermometer, Palmer Wahl HSICBB-P Portable Calibration Black Body, Palmer Wahl DHS520L Heat Spy High Temperature IR Thermometer, Palmer Wahl C150 Documenting Multifunction Calibrator, Palmer Wahl TC622A Pocket RTD Calibrator and Palmer Wahl 1050 Direct Drive 5 Inch Dial Thermometer.
Datasheets & Documents
- Datasheet Palmer Wahl DSPG Digi-Stem digital pressure gauge datasheet (May 2026) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Palmer Wahl Instrumentation Group is an American maker of thermometers, temperature and pressure calibrators and infrared instruments, based in Asheville, North Carolina, since 1987. It traces its roots to 1836, when James Foster, Jr. & Co. began making thermometers in Cincinnati. Charles Palmer introduced his red-reading mercury thermometer in 1929, and Palmer acquired Wahl Instruments in 1997.
Seven Star LLC is an independent supplier in Muscat. We list Palmer Wahl thermometers, calibrators and test instruments for maintenance and calibration teams in Oman and the GCC.
Palmer Wahl company profile
| Origins | 1836, Cincinnati, Ohio, as James Foster, Jr. & Co. |
|---|---|
| Headquarters | Asheville, North Carolina (since 1987) |
| Key product | Red-reading mercury thermometer, Charles Palmer, 1929 |
| Merger | Acquired Wahl Instruments, 1997 |
| Product families | Bimetal and industrial dial thermometers, Digi-Stem RTD thermometers, documenting multifunction calibrators, pocket RTD and thermocouple calibrators, portable black body sources, infrared thermometers |
Milestones
- 1836: Thermometer making begins in Cincinnati.
- 1929: Charles Palmer introduces the red-reading thermometer.
- 1987: The company moves to Asheville.
- 1997: Palmer acquires Wahl Instruments.
Palmer Wahl product series
Thermometers include the 1050 direct-drive 5-inch dial thermometer, the All Star bimetal thermometers in 3 and 5 inch sizes, the 9AL and 9FL economy industrial thermometers and the DST600 and DST640 Digi-Stem RTD thermometers. The DHS520L Heat Spy is a high-temperature infrared thermometer.
Calibration and test equipment includes the TC622A pocket RTD calibrator, the C150 documenting multifunction calibrator, the P32 handheld process signal calibrator, the HSICBB-P portable black body for checking infrared thermometers and the DSPG digital pressure gauge data logger.
Where Palmer Wahl instruments are used
Temperature indication on tanks, pipes and process equipment, field calibration of loops and temperature transmitters, infrared temperature checks on furnaces and kilns, and pressure logging during tests.
Palmer Wahl products we list
Ordering Palmer Wahl instruments: what we need
Send the instrument family, range, stem or probe length, process connection, case style and any calibration certificate or mercury-free requirement. The datasheet ordering guides allow the full code to be confirmed before an offer is issued.
Facts checked against Palmer Wahl's own company history (palmerwahl.com), October 2026.
Browse Palmer Wahl products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Palmer Wahl DSPG Digital Pressure Gauge Data Logger
Answers from our engineering team on installation, compatibility and integration.
01What accuracy options does the DSPG offer?
Plus or minus 0.1 percent of full scale at 23 C, or plus or minus 0.05 percent of full scale from 0 to 50 C with a 9-point NIST Certificate of Conformance.
02How much data can it log?
The built-in logger records up to 1,000,000 pressure readings with date and time stamps.
03What is its ingress protection?
NEMA 6P and IP68, dust tight and surviving water submersion up to 1 meter.
04Does it have an analog output?
An optional transmitter gives 4 to 20 mA or 0 to 5 V and needs a customer-supplied 24 V DC loop supply.
05Is Seven Star LLC a distributor of Palmer Wahl?
No. Seven Star LLC is an independent supplier in Muscat that sources genuine products on request; we do not claim any distributor status.


















Reviews
There are no reviews yet.