Schneider Electric XB5AVG6 Blue Pilot Light 110-120 V AC

Description

XB5AVG6: blue 110–120 V AC Harmony XB5 pilot light

The XB5AVG6 is a Schneider Electric Harmony XB5 pilot light for a 22 mm panel hole. It has a dark grey plastic bezel, a round blue plain lens, an integral universal LED and a rated supply of 110 to 120 V AC at 50/60 Hz. Seven Star LLC supplies the XB5AVG6 in Oman and the GCC as an independent supplier based in Muscat, normally to panel builders, maintenance stores and EPC contractors who need a light, economical indicator for a control panel door.

The datasheet titles of the 10 references in this group suggest a reading that we offer as our own interpretation, not a manufacturer ordering table: XB5AV is the plastic pilot light with an integral LED, the letter after it (G) sets the supply, and the digit (6) sets the lens colour. The XB5AVG6 is built as a head that sits on a separate rear block, with the LED carried in the unit behind the lens.

Selection checklist and RFQ information for XB5AVG6

Send the points below so that the part number can be confirmed against the datasheet and checked for availability in one reply.

  • Part number XB5AVG6 and the required quantity.
  • The lamp circuit supply, here 110 to 120 V AC at 50/60 Hz.
  • The lens colour (blue) and its meaning on your legend.
  • Panel thickness at the hole, against the 1 to 6 mm clamping range.
  • Rear clearance behind the panel, against the body depth.
  • Any approval needed by the project, compared with the datasheet listing.
  • Delivery location in Oman or the GCC and the lead time you need.

Technical specifications of the XB5AVG6

Parameter Specification
Manufacturer / part number Schneider Electric / XB5AVG6
Range Harmony XB5
Product type Pilot light, plastic bezel
Device presentation Complete product
Bezel / fixing collar Dark grey plastic / plastic
Head shape Round
Lens Blue, with plain lens
Light source / bulb base Universal LED / Integral LED
Rated supply voltage [Us] 110 to 120 V AC at 50/60 Hz
Supply voltage limits 100–132 V AC
Current consumption 14 mA
Signalling type Steady
LED service life 100000 h at rated voltage and 25 °C
Mounting diameter 22.5 mm
Terminal marking (ISO) (X1-X2)PL
Terminals Screw clamp; up to 2 × 1.5 mm² with cable end, or 1 × 0.22 to 2 × 2.5 mm² without cable end
Rated insulation voltage [Ui] 250 V, pollution degree 3
Rated impulse withstand [Uimp] 4 kV
Surge withstand 1 kV (IEC 61000-4-5)
Dimensions (H x W x D) 42 mm × 30 mm × 54 mm
Net weight 0.038 kg
Degree of protection IP66, IP67, IP69, IP69K; UL type 4X/13; IK05
Operating / storage temperature -40 to 70 °C / -40 to 70 °C
Vibration / shock 5 gn, 12–500 Hz / 30 gn 18 ms and 50 gn 11 ms
Certifications CSA, UL listed
Warranty 18 months

Mounting and wiring of the XB5AVG6

The XB5AVG6 mounts in a standard 22.5 mm round hole, and the dimension drawing in the datasheet gives a clamping thickness of 1 to 6 mm. The body measures 42 mm high, 30 mm wide and 54 mm deep behind the panel face and weighs 0.038 kg. The rear depth is the figure to check on shallow doors and when several lamps are stacked close to a terminal rail.

Connection is by screw clamp terminals marked (X1-X2)PL under the ISO numbering. The datasheet permits up to two conductors of 1.5 mm² with cable ends, or a single conductor from 0.22 mm² up to two of 2.5 mm² without ends. The head resists a high-pressure washer at 7000000 Pa and 55 °C from 0.1 m according to the datasheet, a useful figure for washdown areas.

Where a blue indicator belongs

Blue is the least used colour on a panel and is normally kept for mandatory-action or special-purpose indications such as a manual reset needed, local control selected or a maintenance state. Because few lamps use it, it stands out well beside red and green rows. The plain lens of the XB5AVG6 carries no legend, so the function is normally identified by a nameplate or an engraved label beside it. Siblings in the same colour, XB5AVM6, differ only in supply voltage. When several lamps share a door, keep the colours in the same order from panel to panel so that an operator moving between plants reads each one the same way.

Supply, LED and signalling of the XB5AVG6

The 110–120 V AC rating fits panels with a 110 V control transformer secondary, a pattern common on motor control centres that were specified to American or older British practice. It is an AC lamp circuit, so it is not for DC supplies. Other references in this group with the same supply include XB5AVG1, XB5AVG5, so a mixed row of colours can share one lamp circuit.

The datasheet lists the supply limits as 100–132 V AC and the current consumption as 14 mA, which is small enough for a long row of lamps on one control fuse. The light source is a universal LED with an integral base, so there is no bulb to change. The stated service life is 100000 h at rated voltage and 25 °C, and the signalling type is steady. A note at the head of the datasheet says a change in appearance may be seen on the product without affecting function or safety, and that this keeps it compatible with the manufacturer’s universal LED blocks.

The XB5AV group and how XB5AVG6 differs

The 10 references share the same plain-lens round head, integral LED and 22 mm mounting. They separate on lens colour and supply voltage only, so selection is a two-step choice: first the supply of your lamp circuit, then the colour from your panel legend. The XB5AVG6 is the blue 110–120 V AC member.

Reference Lens colour Supply
XB5AVB4 Red 24 V AC/DC
XB5AVB5 Orange 24 V AC/DC
XB5AVG1 White 110–120 V AC
XB5AVG5 Orange 110–120 V AC
XB5AVG6 Blue 110–120 V AC
XB5AVM1 White 230–240 V AC
XB5AVM3 Green 230–240 V AC
XB5AVM4 Red 230–240 V AC
XB5AVM5 Orange 230–240 V AC
XB5AVM6 Blue 230–240 V AC

Sealing, immunity and approvals of the XB5AVG6

The datasheet lists protection ratings of IP66, IP67, IP69, IP69K, with UL type 4X/13 and IK05 impact protection. Storage is rated from -40 to 70 °C and operation from -40 to 70 °C, a window that covers a summer-heated switch room and most unheated outdoor cabinets. Vibration resistance is 5 gn between 12 and 500 Hz, and the shock figures are 30 gn for 18 ms and 50 gn for 11 ms.

Electromagnetic data are given too: 1 kV surge withstand, 2 kV fast transients, 10 V/m field immunity, 6 kV contact and 8 kV air electrostatic discharge, and Class B emission. The certifications listed for this reference are CSA, UL listed. Marine and offshore buyers sometimes ask for ship-classification marks; this unit should only be accepted against a requirement that appears in the datasheet for this exact reference, and this one lists no marine approval.

Typical uses of XB5AVG6 in Oman and the GCC

Indicators of this class, including this unit, are common on motor control panels, pump and fan starters, water treatment skids, switchgear doors and packaged equipment throughout the region. In oil and gas and petrochemical sites they sit on local control stations and auxiliary panels; in power and desalination plants they mark pump status, valve position and supply healthy.

The plastic bezel is light and economical, and the sealed head with its IP66 to IP69K list copes with dust, heat and humidity when the panel itself is properly specified.

Documents and quotation

The Schneider Electric datasheet for the XB5AVG6 is attached on this page for your technical file. It carries the electrical, mechanical and environmental data summarised above, together with the dimension and panel cut-out drawings.

To request a quotation, send the part number and quantity through the enquiry form and we will reply with availability and delivery terms. Seven Star LLC is an independent supplier and does not act for the manufacturer, so please check the datasheet against your project requirements before ordering.

Other Models in the Se Xb5av Pilot Range

Seven Star LLC supplies models from the Se Xb5av Pilot range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric XB5AVB4 Red Pilot Light 24 V AC/DCAutomation AccessoriesView details
Schneider Electric XB5AVB5 Orange Pilot Light 24 V AC/DCAutomation AccessoriesView details
Schneider Electric XB5AVG1 White Pilot Light 110-120 V ACAutomation AccessoriesView details
Schneider Electric XB5AVG5 Orange Pilot Light 110-120 V ACAutomation AccessoriesView details
Schneider Electric XB5AVG6 Blue Pilot Light 110-120 V ACAutomation AccessoriesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric XB5AVG6 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric XB5AVG6 Blue Pilot Light 110-120

Answers from our engineering team on installation, compatibility and integration.

01What supply does the XB5AVG6 use?
The datasheet lists 110 to 120 V AC at 50/60 Hz, with supply limits of 100–132 V AC and a current consumption of 14 mA.
02Can the lamp of the XB5AVG6 be changed?
The datasheet lists the bulb base as an integral LED, so there is no bulb to exchange. A failed unit is replaced as a whole.
03What panel hole does the XB5AVG6 need?
A round 22.5 mm hole, with a clamping thickness of 1 to 6 mm according to the datasheet drawing. Terminals are screw clamp type.
04What protection rating does the XB5AVG6 list?
IP66, IP67, IP69 and IP69K, with UL type 4X/13 and IK05, and operation from -40–70 °C.
05Does Seven Star LLC supply the XB5AVG6 in Oman?
Yes, as an independent supplier in Muscat serving Oman and the GCC. Send the part number and quantity and we confirm availability and documents.