Schneider Electric R9F12340 Resi9 3P 40 A C-curve MCB

Description

R9F12340: Resi9 3P 40 A C-curve miniature circuit breaker

The R9F12340 is a Schneider Electric Resi9 miniature circuit breaker with three protected poles, a 40 A rated current and a C trip curve. It is a thermal-magnetic device for AC networks, clips onto a DIN rail and is described by the datasheet as a protection device under EN/IEC 60898-1. Seven Star LLC supplies the R9F12340 in Oman and the GCC as an independent supplier based in Muscat.

Decoding the title: 3P means three poles, 40 A is the rated current [In], and the C curve defines how far above rating the magnetic release acts. The datasheet states a breaking capacity of 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1. A 40 A rating is the largest in this four-reference group. It serves sub-distribution feeders, bigger heater banks and the incomer of small process cabinets.

Technical specifications of the R9F12340

Parameter Specification
Manufacturer / part number Schneider Electric / R9F12340
Range / product name Resi9 / Resi9 MCB
Product type Miniature circuit-breaker
Device application Protection
Poles 3P (3 protected poles)
Rated current [In] 40 A
Network type / frequency AC, 50/60 Hz
Trip unit / curve Thermal-magnetic, curve C
Rated operational voltage [Ue] 400 V AC 50/60 Hz
Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Magnetic tripping limit 5–10 x In AC
Limitation class 3 conforming to EN/IEC 60898-1
Rated insulation voltage [Ui] 440 V AC
Rated impulse withstand [Uimp] 4 kV
Control / indication Toggle; ON/OFF indication
Mounting Clip-on on DIN rail; 6 pitches of 9 mm
Dimensions (H x W x D) 81 mm x 54 mm x 72 mm
Embedding depth 44 mm
Net weight (datasheet) 360 g
Colour White (RAL 9003)
Terminals Tunnel type, top or bottom: 35 mm² rigid, 25 mm² flexible with ferrule, 25 mm² flexible
Stripping length / torque 14 mm; 3.5 N.m
Durability 20000 cycles mechanical, 10000 cycles electrical
Earth-leakage protection Without
Standard / quality labels EN/IEC 60898-1; EAC; UA TR
Protection / pollution degree IP20; pollution degree 2 conforming to EN/IEC 60898-1
Overvoltage category III
Tropicalisation 2 conforming to IEC 60068-1
Operating temperature -25–60 °C
Storage temperature -40–60 °C
Relative humidity 95 % at 55 °C

What the 40 A rating and C curve mean for the R9F12340

The magnetic tripping limit is listed as 5–10 x In AC. Multiplying by the 40 A rating gives an instantaneous trip zone of roughly 200 A to 400 A; this is our own arithmetic from the datasheet figure, not a separate published value. Below that zone the thermal element handles overloads with an inverse-time characteristic, so a modest overload trips slowly and a short circuit trips at once.

A C curve tolerates the inrush of lamps, small motors and transformers better than a B curve and is the usual choice for mixed loads. The limitation class is shown as 3 conforming to EN/IEC 60898-1, which describes how strongly the device limits let-through energy under fault. For long cable runs, check that the earth-fault loop is low enough for the R9F12340 to reach its magnetic zone.

Three-pole layout, terminals and mounting of the R9F12340

All three poles are mechanically linked, so an overload or fault on any one phase opens every pole together and no single-phasing of a motor or three-phase load is left behind. The body is 81 mm high, 54 mm wide (6 modules of 9 mm) and 72 mm deep, with an embedding depth of 44 mm.

Terminals are tunnel type at top and bottom and accept 35 mm² rigid, 25 mm² flexible with ferrule or 25 mm² flexible conductor. Strip 14 mm and tighten to 3.5 N.m. This is the highest torque and largest conductor range in the four-reference group, so use a screwdriver and bit that suit the bigger screw.

The R9F12340 among Resi9 3P C-curve references

The nearest siblings by rating are R9F12332 (32 A) and R9F12325 (25 A). All four references share the same 6000 A breaking-capacity class, six-module body and DIN-rail fixing; they differ in rated current, terminal capacity, torque and the carbon-footprint figures printed on their datasheets.

Reference Rated current Terminal range, rigid Tightening torque Carbon footprint
R9F12320 20 A 25 mm² 2 N.m 54 kg CO2 eq.
R9F12325 25 A 25 mm² 2 N.m 58 kg CO2 eq.
R9F12332 32 A 25 mm² 2 N.m 64 kg CO2 eq.
R9F12340 (this page) 40 A 35 mm² 3.5 N.m 72 kg CO2 eq.

The operating voltage, curve and standards are identical across the group, so the choice comes down to current rating and conductor size.

Installation and maintenance of the R9F12340

Isolate the board before work and clip this unit onto the rail until it seats. Operate the toggle once to confirm the ON/OFF indication moves cleanly, connect the incoming conductors to the top terminals as per the board layout and tighten to 3.5 N.m. Label the way clearly, as three identical breakers side by side are easy to confuse.

The datasheet gives mechanical durability of 20000 cycles and electrical durability of 10000 cycles. In maintenance rounds, re-torque terminals where the board vibrates, look for discoloured plastic that signals a loose connection, and press any test routine your plant requires. A breaker that has tripped on a short circuit should be investigated before it is reset.

Environment, packaging and warranty for the R9F12340

Operation is specified from -25–60 °C, storage from -40–60 °C, with relative humidity of 95 % at 55 °C and tropicalisation level 2 conforming to IEC 60068-1. Protection is IP20 at the device face, so the breaker belongs inside an enclosure; overvoltage category is III and pollution degree 2 conforming to EN/IEC 60898-1. For environmental reporting, the datasheet gives a total lifecycle carbon footprint of 72 kg CO2 eq., of which 2 kg is the manufacturing phase and 70 kg the use phase; a recyclability potential of 47 %; EU RoHS status shown as compliant.

Packing and warranty item Value
Single unit weight 354.000 g
Units in intermediate package 4
Units in large package 48
Intermediate package weight 1.460 kg
Large package weight 18.021 kg
Warranty 18 months

Information to send with an RFQ for the R9F12340

  • Full reference (this unit) and quantity, and whether it replaces an existing breaker.
  • System voltage, frequency and prospective short-circuit current at the board.
  • Conductor type and cross-section, so terminal capacity can be checked.
  • Load type (lighting, motor, heater) to confirm that the C curve is appropriate.
  • Delivery location in Oman or the GCC and the required date.

Documents and quotation

The manufacturer datasheet for the R9F12340 is attached on this page and carries the full specification summarised above. Check the revision date on the datasheet against your project requirement.

To request a quotation, send the part number R9F12340, the quantity and your delivery location in Oman or the GCC. Seven Star LLC replies with availability and lead time as an independent supplier.

Other Models in the Se Resi9 Mcb 3p C Range

Seven Star LLC supplies models from the Se Resi9 Mcb 3p C range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric R9F12320 Resi9 3P 20 A C-curve MCBCircuit BreakersView details
Schneider Electric R9F12325 Resi9 3P 25 A C-curve MCBCircuit BreakersView details
Schneider Electric R9F12332 Resi9 3P 32 A C-curve MCBCircuit BreakersView details
Schneider Electric R9F12340 Resi9 3P 40 A C-curve MCBCircuit BreakersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric R9F12340 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric R9F12340 Resi9 3P 40 A C-curve

Answers from our engineering team on installation, compatibility and integration.

01What is the rating of the R9F12340?
The datasheet lists a 40 A rated current, 3 poles, C curve and a thermal-magnetic trip unit, with 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1.
02What is the magnetic trip range of the R9F12340?
The magnetic tripping limit is 5–10 x In AC, which for 40 A works out to about 200 to 400 A. The arithmetic is ours; the multiplier comes from the datasheet.
03What size is the R9F12340 and how is it mounted?
It is 54 mm wide (6 modules), 81 mm high and 72 mm deep, and clips onto a DIN rail.
04What conductors fit the R9F12340 terminals?
Tunnel terminals at top or bottom take 35 mm2 rigid, 25 mm2 flexible with ferrule or 25 mm2 flexible. Strip 14 mm and tighten to 3.5 N.m.
05Which standard is listed for the R9F12340?
The datasheet names EN/IEC 60898-1 and lists the quality labels EAC and UA TR. Protection is IP20 with an 18-month warranty.