Schneider Electric C10N1TM020 NSX100N 1P 20 A AC/DC Breaker

Description

C10N1TM020: one-pole 20 A ComPacT NSX100N for AC and DC circuits

The C10N1TM020 is a Schneider Electric ComPacT NSX circuit breaker listed in its datasheet as: Circuit breaker ComPacT NSX100N AC/DC, 25kA at 240VAC, TMD trip unit 20A, 1 pole 1d. It is the narrowest and lowest-rated member of the one-pole NSX100N group, only 35 mm wide, and it carries a thermal-magnetic trip unit rather than an electronic one. Seven Star LLC supplies the C10N1TM020 in Oman and the GCC as an independent supplier based in Muscat.

The reference breaks down as follows. C10 is the NSX100 frame, N is the breaking-capacity class (the datasheet code reads N 25 kA 240 V AC), 1 means one pole, TM is thermal-magnetic and 020 is the 20 A rating. The datasheet device short name is NSX100N, the poles description is 1P with one protected pole (1D), and the trip unit is a TM-D. This page describes only what the datasheet states for the C10N1TM020; it does not describe other ratings of the family except where noted.

Technical specifications of the C10N1TM020

Parameter Specification
Manufacturer / part number Schneider Electric / C10N1TM020
Range / product name ComPacT / ComPacT NSX
Device short name NSX100N
Product type Circuit breaker, distribution application
Poles / protected poles 1P / 1D
[In] rated current 20 A at 40 °C
[Ue] rated operational voltage 277 V AC 50/60 Hz; 250 V DC
Network type AC; DC
Breaking capacity (Icu) 25 kA at 220/240 V AC 50/60 Hz; 50 kA at 250 V DC (IEC 60947-2)
Breaking capacity code N 25 kA 240 V AC
[Ics] rated service breaking capacity 25 kA at 220/240 V AC; 50 kA at 250 V DC
Trip unit TM-D, thermal-magnetic, protection functions LI
[Ii] instantaneous pick-up 190 A, fixed
[Ir] long-time pick-up 1 x In, fixed
Suitability for isolation Yes, EN/IEC 60947-2; Category A
[Ui] / [Uimp] 750 V AC 50/60 Hz / 8 kV
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 277 V In/2; 10000 cycles at 277 V In
Power dissipation per pole 4.01 W
Control / mounting mode Toggle / fixed, on backplate
Connections Front, upside and downside; pitch 35 mm
Dimensions W x H x D 35 x 161 x 86 mm
Net weight 0.7 kg
Protection degree IP40 (IEC 60529); IK07 (IEC 62262); Class II on front face
Pollution degree / overvoltage category 3 / IV
Relative humidity 0 to 95 %
Operating altitude 0 to 2000 m without derating; 2000 to 5000 m with derating

AC and DC ratings of the C10N1TM020 in plain terms

Most one-pole breakers are single-purpose, but the C10N1TM020 is rated for both supply types. On alternating current the datasheet gives 277 V AC at 50/60 Hz with an Icu of 25 kA at 220/240 V AC. On direct current it gives 250 V DC with an Icu of 50 kA. The Ics (service breaking capacity) values equal the Icu values for both cases: 25 kA on AC and 50 kA on DC.

The DC rating applies to the single pole at 250 V DC, so a design needing more than 250 V DC across a break, or AC above 277 V per pole, has to be checked against the manufacturer documentation.

The practical consequence is that selection happens at the order stage. A load with a high inrush (small motors, transformers, discharge lighting banks) should be checked against the 190 A threshold, because an inrush peak above it would open the breaker instantly. A load with a steady current close to 20 A should also be reviewed for ambient temperature, since the rating is stated at 40 °C.

Where the C10N1TM020 differs from its sibling ratings

The one-pole NSX100N group also includes other ratings, such as the C10N1TM063, which is the highest rating treated here: its datasheet gives 63 A, an instantaneous pick-up of 500 A and a dissipation of 8.61 W per pole, while the C10N1TM020 shows 20 A, 190 A and 4.01 W per pole. Dimensions and weight are the same in both datasheets, so the choice between them changes the protection level and the heat inside the enclosure, not the panel cut-out.

Part number Rated current In Instantaneous pick-up Dissipation per pole
C10N1TM020 20 A 190 A 4.01 W
C10N1TM063 63 A 500 A 8.61 W

Selection checklist before ordering the C10N1TM020

  • Circuit voltage: not above 277 V AC or 250 V DC per pole, with the fault level at the point of installation not above the 25 kA (AC) or 50 kA (DC) Icu.
  • Load current: a continuous current that stays at or below 20 A at 40 °C panel temperature, with margin for the actual enclosure conditions.
  • Inrush: confirm that the starting or switching peak stays below the fixed 190 A instantaneous setting.
  • Isolation: the datasheet confirms suitability for isolation under EN/IEC 60947-2, Category A, which matters for maintenance procedures.
  • Poles: one protected pole (1D). Where all conductors must be broken, a multi-pole NSX breaker is needed instead.
  • Altitude: full rating up to 2000 m; derating applies from 2000 m to 5000 m.

Mounting, wiring and maintenance of the C10N1TM020

The C10N1TM020 is a fixed breaker mounted on a backplate, horizontally, vertically or flat on its back. Connections are made at the front on both the upside and the downside, on a 35 mm connection pitch. The toggle control gives a visible handle position, and the datasheet places the front face in Class II for electrical shock protection with IP40 and IK07 protection degrees. IP40 protects against solid objects over 1 mm but not against water, so the breaker belongs inside a suitable enclosure when used in dusty or damp locations.

For maintenance, the mechanical durability is 20000 cycles and the electrical durability is 20000 cycles at 277 V and half of In, or 10000 cycles at 277 V and full In. These figures help planners decide how often a breaker used as a frequent switching device should be reviewed. After any fault trip, inspect conductors and terminations before resetting. Keep the datasheet with the panel records.

Typical applications of the C10N1TM020 in Oman and the GCC

Single-pole AC/DC breakers of this size find use in compact distribution boards, DC auxiliary supplies such as battery and rectifier circuits at 250 V DC, telecom and control cabinets, and small-load feeders in utility, oil and gas and water treatment plants. In the Gulf climate the main practical points are heat inside a closed enclosure and fine dust. The dissipation of 4.01 W per pole is small, but it adds up when several breakers sit side by side in a cabinet in direct sun. Humidity up to 95 % is stated in the datasheet, and the enclosure should still be sealed against condensation and dust during commissioning.

Information to send with an RFQ for the C10N1TM020

  • The full part number C10N1TM020 and the quantity.
  • System voltage and type (AC or DC) and the available fault current.
  • Load description and expected inrush.
  • Enclosure type, ambient temperature and altitude.
  • Required delivery location and any documents needed with the shipment.

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it is the document to check against your own drawings.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Compact Nsx100n 1p Range

Seven Star LLC supplies models from the Se Compact Nsx100n 1p range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric C10N1TM020 NSX100N 1P 20 A AC/DC BreakerCircuit BreakersYou are viewing this model
Schneider Electric C10N1TM063 NSX100N 1P 63 A AC/DC BreakerCircuit BreakersView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric C10N1TM020 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric C10N1TM020 NSX100N 1P 20 A AC/DC

Answers from our engineering team on installation, compatibility and integration.

01What is the rated current of the C10N1TM020?
The datasheet gives a rated current In of 20 A at 40 °C. The thermal-magnetic trip unit is fixed, so the rating cannot be adjusted after purchase.
02Can the C10N1TM020 be used on DC?
Yes. The datasheet lists a rated operational voltage of 250 V DC and an Icu of 50 kA at 250 V DC for this one-pole breaker, in addition to 277 V AC.
03What is the instantaneous trip level of the C10N1TM020?
The datasheet gives a fixed instantaneous pick-up of 190 A and a fixed long-time pick-up of 1 x In. Check motor or transformer inrush against 190 A.
04How wide is the C10N1TM020?
The width is 35 mm, the height 161 mm and the depth 86 mm, with a net weight of 0.7 kg according to the datasheet.
05Is the C10N1TM020 suitable for isolation?
The datasheet states suitability for isolation conforming to EN/IEC 60947-2, Category A. It protects one pole only.