Brand:

Parker SCP-400-74-02 SCP Pressure Sensor, 0 to 400 bar

Description

SCP-400-74-02 pressure sensor for hydraulic working pressure

The Parker SCP-400-74-02 is a analogue pressure sensor from the SCP (SensoControl) range, built as a diagnostic sensor for Parker hand-held and portable measuring instruments. This is the version that matches typical industrial and mobile hydraulic working pressure, with a measuring range of 0 to 400 bar. It is made of stainless steel, uses a strain-gauge measuring element and is delivered with a diagnostic adapter installed, so it can be connected to a measuring point in seconds.

How to read the part number SCP-400-74-02

Element Meaning
SCP Pressure sensor from the SCP series
400 Measuring range code: 0 to 400 bar
74 Analogue output for Parker hand meters
02 Analogue 5-pin electrical connection

Parker also lists a PD-adapter version of most analogue ranges, with the suffix -PD, and a calibration-certificate version with the prefix K-. This page covers the standard version SCP-400-74-02.

SCP-400-74-02 technical specifications

Parameter Specification
Manufacturer / part number Parker / SCP-400-74-02
Product Pressure sensor, SCP series (SensoControl)
Measuring range 0…400 bar (0…5800 psi)
Output type analogue signal for hand meters
Technology Strain gauge (DMS)
Overload pressure 800 bar (11600 psi)
Burst pressure 2000 bar (29000 psi)
Accuracy (full scale) ± 0.5 % + 0.2 %/year
Electrical connection 5-pin plug-in connection
Process connection 1/4" BSPP, supplied with a diagnostic adapter (M16x2) fitted
Housing / seal Stainless steel / FKM
Body diameter 22 mm
Weight approx. 200 g
Ambient temperature -25…+85 °C
Media temperature -25…+105 °C
Storage temperature -20…+85 °C
Shock / vibration 50 g / 11 ms (IEC 60068-2-27); 20 g (IEC 60068-2-6)
Load cycles 100 million
Protection class IP54 (EN 60529)
Specifications met CE

How the SCP-400-74-02 measures pressure

Inside the stainless-steel body a strain-gauge sensing element converts the pressure acting on it into an electrical signal. The signal is delivered as an analogue value through the 5-pin plug-in connector to a compatible Parker hand meter. Because the sensing element is small and stiff, the sensor follows fast pressure changes and can record short peaks that a mechanical gauge would miss.

The sensor is intended to be used with a measuring hose and a test-point coupling rather than being threaded permanently into a line. The diagnostic adapter that is already installed on the 1/4" BSPP port ends in an M16x2 female thread, which matches the EMA-3 measuring connection used on Parker test points. This keeps the connect-and-disconnect time short and avoids the use of loose fittings.

Instruments and accessories that work with SCP-400-74-02

The analogue SCP sensors work with the Parker Serviceman Plus SCM-155-0-02 and with the Service Master CONNECT SCM-600 when it is fitted with an analogue input module SCMI-600-01 or SCMI-600-03. The sensor connects to the meter through SCK-102 cables, which Parker lists as SCK-102-03-02 (3 m), SCK-102-05-02 (5 m) and SCK-102-05-12 (5 m extension, with a female end). Related sensors from the same catalogue include the other analogue ranges (SCP-015-74-02, SCP-060-74-02, SCP-150-74-02, SCP-400-74-02, SCP-600-74-02 and SCP-1000-74-02) and the combined pressure and temperature sensors SCPT-xxx-02-02.

The measuring chain also includes the measuring hose (SMA3 series), the adapter SCA-EMA-3/3 and the measuring connection EMA-3 on the system side. Check that each element is rated for the pressure you intend to measure.

Choosing the SCP-400-74-02 range

The 400 bar range is the usual first choice for general hydraulic diagnostics, because most systems run between 100 and 350 bar. The 800 bar overload rating means relief-valve opening and pump pressure peaks stay inside the sensor limit, and the burst figure of 2000 bar gives a large reserve. Choose it when you need to set a relief valve, verify pump compensator settings, or log cylinder pressure on a press, lift or injection-moulding machine. If your system is limited to about 250 bar or less and you want finer resolution, the 150 range can be the better match, while systems with working pressure above 400 bar need the 600 or 1000 range.

  • Relief-valve setting and pump compensator checks
  • Cylinder and motor pressure logging on presses and lifts
  • Hydraulic power units on cranes and mobile machinery
  • Post-repair acceptance testing of hydraulic circuits

Selection and ordering checklist for SCP-400-74-02

  • Confirm the highest working pressure and the highest expected peak, and compare both with the 0 to 400 bar range and the overload rating.
  • Confirm that your hand meter or data logger has a matching analogue sensor input.
  • Decide whether you need the standard adapter, the PD adapter variant or a calibration certificate (K- prefix).
  • Check the process connection: 1/4" BSPP male on the sensor, with an M16x2 female diagnostic adapter.
  • Check the media: the sensor housing is stainless steel and the seal is FKM, with a media temperature of -25 to +105 °C.
  • Plan the cables and, for CAN, the terminating resistor.

Use, care and maintenance of the SCP-400-74-02

Always depressurise the circuit before connecting or removing the sensor, and use a measuring hose with a rating at or above the highest pressure. Connect the sensor to the test point, then the cable to the meter, and only then pressurise the system. Remove the sensor when the measurement is complete rather than leaving it on the machine, as it is a diagnostic tool and not a permanent transmitter.

Accuracy is stated as ± 0.5 % of full scale plus 0.2 % per year, which means a periodic check or recalibration is part of normal use. Store the sensor in a clean, dry place between jobs, keep the connector clean and dry, and replace the cable when the insulation or the plug shows wear. The sensor is rated IP54, so it should be kept away from jets of water and from heavy contamination when in use.

Where the SCP-400-74-02 is used in Oman and the GCC

Common uses in the Gulf include relief-valve setting and pump testing on hydraulic power units for valves, cranes and workover equipment, pressure logging on heavy mobile machinery in construction and mining, and acceptance testing after a hydraulic repair. The stainless-steel body copes with the humidity and salt air at coastal sites better than a plated housing would.

Heat is a factor on exposed equipment in the Gulf. The ambient range is -25 to +85 °C and the media range reaches +105 °C, so a sensor left on a sun-heated line should be checked against those limits. Fine dust and humidity are also constant concerns, which makes it wise to cap the connector and the diagnostic adapter when the sensor is stored.

Information to send with an RFQ for SCP-400-74-02

  • Part number SCP-400-74-02 and quantity
  • Standard, PD adapter or calibration-certificate version
  • Meter model or logger that the sensor will connect to
  • Cable lengths and accessories needed
  • Project name, site and delivery location

Documents and quotation

Send us the part number SCP-400-74-02 and the required quantity, and we will confirm the available documents and the lead time.

Seven Star LLC supplies Parker pressure sensors and other hydraulic and pneumatic products in Oman and the GCC from Muscat.

Other Models in the Parker Scp Analogue Range

Seven Star LLC supplies models from the Parker Scp Analogue range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Parker SCP-015-74-02 SCP Pressure Sensor, -1 to 15 barPressure InstrumentationView details
Parker SCP-060-74-02 SCP Pressure Sensor, 0 to 60 barPressure InstrumentationView details
Parker SCP-400-74-02 SCP Pressure Sensor, 0 to 400 barPressure InstrumentationYou are viewing this model
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.

Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.

Parker company profile

Founded 1917, Cleveland, Ohio, USA, by Arthur L. Parker
Headquarters Cleveland area, Ohio, USA
Ownership Public company, New York Stock Exchange (PH), listed since 1964
First product Pneumatic brake system for trucks and buses
Product families Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings

Milestones

  • 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
  • 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
  • 1957: Parker acquires Hannifin and becomes Parker Hannifin.
  • 1964: The shares are listed on the New York Stock Exchange.

Parker product lines listed here

Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.

Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.

Where Parker components are used

Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.

Parker products we list

Family Examples
Solenoid Valves 7341NAKBHNM0 Lucifer Series Solenoid Valve, Lucifer 322K4706 2-Way Solenoid Valve, Lucifer 341N01 NAMUR Solenoid Valve, Lucifer 341N22 SOLENOID VALVE, Lucifer 341N31 NAMUR Solenoid Valve, Lucifer E131K03 Solenoid Valve
Filtration Elements 9000040001 Coalescing Filter Element
Pumps P51A478BEY25-07-ZY Hydraulic Gear Pump
Pipes & Fittings Triple-Lok 37° Flare Tube Fitting

Ordering Parker parts: what we need

Parker part numbers are long and every character counts. Please send:

  • Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
  • Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
  • Filter elements: element number and the housing model it fits

A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.

Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.

FAQ

Questions about the Parker SCP-400-74-02 SCP Pressure Sensor, 0 to 400

Answers from our engineering team on installation, compatibility and integration.

01What is the Parker SCP-400-74-02 used for?
It is a diagnostic pressure sensor for Parker hand-held measuring instruments, used for hydraulic working pressure. It is connected through a test point and a measuring hose and is not meant to stay permanently in the line.
02What pressure range does the SCP-400-74-02 cover?
The measuring range is 0 to 400 bar (0 to 5800 psi). Overload pressure is 800 bar (11600 psi) and burst pressure is 2000 bar (29000 psi).
03Which instruments does the SCP-400-74-02 connect to?
It connects to the Parker Serviceman Plus SCM-155-0-02 and to the Service Master CONNECT SCM-600 with an analogue input module, through SCK-102 cables.
04What are the process and electrical connections of the SCP-400-74-02?
The process connection is 1/4" BSPP male, supplied with a diagnostic adapter that has an M16x2 female thread. The electrical connection is a 5-pin plug-in connector with protection class IP54.
05How accurate is the SCP-400-74-02?
The stated accuracy is ± 0.5 % of full scale plus 0.2 % per year, so periodic recalibration or a replacement is advisable. A version with a calibration certificate per ISO 9001 is listed with the prefix K-.