Brand:

GESTRA SRK 22A Sanitary Non-Return Valve, Clamp, PN 10, DN 15-50

Description

GESTRA SRK 22A Sanitary Non-Return Valve Clamp Connection: overview

The GESTRA SRK 22A is a non-return valve designed for clamp connections to DIN 32676, for pipes to DIN 11866 including DIN 11850, ISO 1127 and ASME BPE. It is rated PN 10 in DN 15 to 50 and is built from stainless steel with a spring so that it can be installed in any plane. The datasheet names installation downstream of GESTRA STERILine SMK 22-8x steam traps and use as a pump non-return valve as particularly suitable applications.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list the GESTRA SRK 22A for buyers who need an exact GESTRA type for a repair, a replacement or a new project and want a clear technical summary before they ask for a quotation. Everything below is condensed from the manufacturer datasheet, so you can compare the SRK 22A with the line conditions on your own drawings. Where a value is not stated in the datasheet, we leave it out rather than guess.

GESTRA equipment is common on steam and condensate systems, boiler houses and process plants, and many installed units in Omani and Gulf facilities are now several years old. That is why buyers often search by the exact type designation such as SRK 22A. Matching the designation, nominal size, pressure rating and connection type is the surest way to get the right replacement, and our team can help check these details against the nameplate or the earlier project documentation before a quotation is issued.

Key features of the SRK 22A

The datasheet describes the following points about the SRK 22A. They explain why this sanitary non-return valve is chosen for its duty and what to look for when comparing it with other options.

  • Clamp connection design, centred by the joint clamp.
  • Spring-loaded for installation in any plane.
  • Stainless steel body 1.4408 (A351 CF8M) and 1.4571 disc, retainer and spring.
  • Plasma polished body, with electropolished surface also available.
  • Metal-to-metal seat or FDA-approved EPDM and FPM seat options.
  • For liquids, gases and vapours.

Technical specifications of the SRK 22A

The table below summarises the main data for the SRK 22A taken from the manufacturer datasheet. Always confirm the final pressure and temperature limits against the datasheet for the exact version and connection you plan to order, because ratings depend on connection type and size.

Parameter Value
Nominal sizes DN 15, 20, 25, 32, 40, 50
Nominal pressure PN 10
Pressure at -200 to 20 C 10.0 bar, falling to 6.0 bar at 185 C
Body 1.4408 / A351 CF8M
Disc, retainer, spring 1.4571 / AISI 316Ti
Outside surface Ra 1.2 micrometre
Surface finish Body plasma polished, electropolished on request
Seat options Metal -200 to 200 C, EPDM -40 to 150 C, FPM -25 to 200 C
Length A 23.0, 29.5, 33.5, 38.0, 43.0, 54.0 mm
Connections Clamp to DIN 32676, ISO 2852, ASME BPE

Typical applications in Oman and the GCC

The SRK 22A is a sanitary non-return valve, and the following use cases show where a unit of this kind is typically applied across oil and gas, utilities, water and manufacturing in Oman and the wider GCC. They are examples based on the described function and not a guarantee of suitability, so the actual operating data should always be checked.

  • Pharmaceutical, food and beverage plants in the GCC use clamp-connected stainless equipment where cleaning and sterilising are routine.
  • It is suited behind sanitary steam traps in clean-steam condensate lines.
  • Utilities with hygienic pump skids use it as a pump non-return valve.

Selection and compatibility notes

Selecting the SRK 22A correctly starts with the process data. Collect the operating pressure, the maximum and minimum temperature, the fluid, the flowrate and the connection standard of the existing pipework, then compare them with the datasheet. The notes below summarise the main decision points for this model.

  • Confirm the tube standard: DIN 11850, ISO 1127 or ASME BPE.
  • Choose EPDM or FPM seats for tight shut-off with FDA approval, and metal for high temperature.
  • Ask for electropolish if the application demands it.

Installation and commissioning of the SRK 22A

Before installing the SRK 22A, flush the line to remove weld spatter, scale and construction debris, because even a robust sanitary non-return valve can be damaged or held open by foreign particles. Check that the flow direction arrow or the marked inlet on the SRK 22A matches the piping, and confirm that the nameplate type, size and pressure rating agree with the purchase documents.

Support the pipework so that no piping stress is transferred to the body of the SRK 22A. Use new gaskets of a type suitable for the fluid and temperature, tighten flange or union bolts evenly and in a cross pattern, and follow the instructions in the manufacturer installation and operating manual for the exact model. If the equipment is used in a potentially explosive area, the plant operator remains responsible for zoning and for preventing static charge, as the datasheet explains for GESTRA equipment.

During commissioning, bring the system up gradually. Open isolation valves slowly, vent trapped air where the design allows, and observe the SRK 22A during the first warm-up for leaks at joints and for unusual noise or vibration. Record the first operating pressure and temperature so that later inspections have a reference.

Maintenance and service

Open the clamp for inspection and cleaning.

Check seat and gasket after each cleaning cycle if soft seats are used.

A short routine inspection plan helps the SRK 22A last longer. Note the date of installation, the service conditions and any events such as water hammer or overpressure. At each planned shutdown, inspect the visible joints, check for external corrosion or leakage and compare performance against the commissioning record. Only use spare parts and gaskets that suit the exact type and rating of the SRK 22A, and isolate and depressurise the line fully before any work is started.

Related products and ordering notes

Orders for the SRK 22A should state the type designation, nominal size, pressure rating, end connection standard, material or version and the quantity required. If you are replacing an existing unit, add the nameplate data and a photograph of the nameplate when possible. The manufacturer family also includes other steam, condensate and flow control products, and we can quote related items together with the SRK 22A when you send a combined enquiry. Seven Star LLC does not publish prices on this page, so each enquiry is answered with a written quotation.

Frequently asked questions

What connection standards apply? Clamp connections to DIN 32676, ISO 2852 and ASME BPE.

What size range is available? DN 15 to 50. Please confirm against the manufacturer datasheet.

Which seat materials are available? Metal-to-metal, FDA-approved EPDM and FDA-approved FPM.

Can it be installed vertically? It has a spring for installation in any plane. Without a spring it is only for vertical lines with upward flow.

Is the surface finish specified? Yes. The body is plasma polished, and electropolished is also available.

Documents and quotation

The manufacturer datasheet for the SRK 22A is attached to this page as a PDF so you can verify every value above and share it with your engineering team. To receive a quotation, send an RFQ that includes the part number SRK 22A, the nominal size, the pressure rating and connection type, and the quantity you need. Our team in Muscat will confirm availability and lead time and reply with a written offer for delivery to Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet GESTRA SRK 22A Sanitary Non-Return Valve, Clamp, PN 10, DN 1 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

GESTRA is the German steam and condensate specialist behind the UNA ball float steam traps, the MPA blowdown valves and a long line of boiler level and conductivity controls. It was founded in Bremen in 1902 by Gustav F. Gerdts, and has been part of Spirax Sarco since 2017.

Seven Star LLC is an independent supplier in Muscat. We list GESTRA steam traps, blowdown valves and boiler control equipment, and supply GESTRA parts and spares to boiler houses and process plants in Oman and the GCC.

GESTRA company profile

Established 29 October 1902, Bremen, Germany, by Gustav Friedrich Gerdts; renamed Gustav F. Gerdts KG in 1907
Ownership history Became a stock corporation (GESTRA AG) in 1987, was taken over by Flowserve in 2002, and has been part of the Spirax Sarco group since 2017
Product families Steam traps, non-return and check valves, boiler blowdown valves, control valves, and boiler control electronics for level, conductivity and temperature
Applications Steam boilers, steam distribution and condensate return in process plants, power stations, hospitals, food and textile plants

Milestones

  • 1902: Gustav Friedrich Gerdts founds the company in Bremen on 29 October.
  • 1907: The company is renamed Gustav F. Gerdts KG.
  • 1987: It becomes a stock corporation, GESTRA AG.
  • 2002: Flowserve takes over GESTRA.
  • 2017: GESTRA becomes part of the Spirax Sarco group.

GESTRA products we list

Series Type What it does
UNA 45, UNA 16, UNA 38 Ball float steam traps Continuous condensate discharge from heat exchangers and process equipment; the UNA 38 is the high-pressure version (PN 100)
BK 45 Bimetallic steam trap Robust trap for steam main drainage and tracing, resistant to water hammer
MK 45, TK 23, SMK 22-81 Thermostatic steam traps Air venting and condensate discharge; the SMK 22-81 is the sanitary version for clean steam
MPA 46 Rapid-action blowdown valve Short, intermittent bottom blowdown that removes sludge from the boiler
NRS 1-54, NRR 2-50, NRR 2-60, NRGT 26-2 Boiler level controls Water level limiting, feedwater control and continuous level measurement
LRGT 16-1, LRR 1-50 Conductivity measurement and control Keeps boiler water conductivity in range through continuous blowdown
TRS 5-50 Safety temperature limiter SIL 3 temperature limiting for boilers and hot water systems

The type of steam trap follows the duty. Ball float traps discharge condensate as soon as it forms, which suits heat exchangers with changing loads. Thermostatic and bimetallic traps hold condensate back slightly and suit steam mains, tracing and air venting. On the boiler itself, GESTRA level and conductivity electronics work as a system: electrodes or transmitters in the boiler, controllers in the panel, and the feedwater and blowdown valves they drive.

Where GESTRA products are used

In Oman and the GCC, GESTRA equipment is used in boiler houses of refineries, petrochemical and fertiliser plants, power and desalination stations, food and beverage plants, laundries, hotels and hospitals.

Ordering GESTRA parts: what we need

Send the type designation, pressure rating (PN) and connection size (DN), the end connection (flanged, screwed or socket weld), the operating pressure and condensate load for steam traps, and the supply voltage and bus type (CAN bus, 4-20 mA) for control equipment. For electrodes, add the insertion length.

Facts checked against GESTRA company history and Bremen city records, October 2026.

FAQ

Questions about the GESTRA SRK 22A Sanitary Non-Return Valve, Clamp, PN

Answers from our engineering team on installation, compatibility and integration.

01What connection standards apply?
Clamp connections to DIN 32676, ISO 2852 and ASME BPE.
02What size range is available?
DN 15 to 50. Please confirm against the manufacturer datasheet.
03Which seat materials are available?
Metal-to-metal, FDA-approved EPDM and FDA-approved FPM.
04Can it be installed vertically?
It has a spring for installation in any plane. Without a spring it is only for vertical lines with upward flow.
05Is the surface finish specified?
Yes. The body is plasma polished, and electropolished is also available.