Brand:

Omron D4N-4120 Safety Limit Switch resin roller lever

Description

D4N-4120 safety limit switch: what it is and how the code reads

The Omron Omron D4N-4120 is a miniature safety limit switch with resin roller lever (resin lever, resin roller), a built-in 1NC/1NO snap-action mechanism and M20 conduit, 1-conduit. Seven Star LLC supplies the Omron D4N-4120 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer. A roller lever is the most common head, and the resin construction suits light machine guards and sliding doors with moderate cam speed.

Reading D4N-@@@@ as described in the datasheet:

  • D4N is the miniature safety limit switch family.
  • 4 is the conduit size: M20 conduit, 1-conduit.
  • 1 is the built-in switch: 1NC/1NO snap-action.
  • 20 is the head and actuator: resin roller lever (resin lever, resin roller).

The snap-action contacts switch quickly regardless of actuator speed, but the NC contact opening gap is smaller than that of slow-action models.

Omron D4N-4120 technical specifications

Parameter Specification
Manufacturer / part number Omron / D4N-4120
Actuator resin roller lever (resin lever, resin roller)
Built-in switch 1NC/1NO snap-action
Conduit M20 conduit, 1-conduit
Rated operating current (AC-15) 3 A at 240 V
Rated operating current (DC-13) 0.27 A at 250 V
Rated open thermal current (Ith) 10 A
Minimum applicable load Resistive load of 1 mA at 5 VDC (reference value)
Contact gap Snap-action 2 x 0.5 mm min.; slow-action 2 x 2 mm min.
Degree of protection IP67 (EN 60947-5-1)
Mechanical durability 15,000,000 operations min.
Electrical durability 500,000 operations min. at 3 A, 250 VAC resistive
Operating frequency 30 operations/minute max.
Protection against electric shock Class II (double insulation)
Rated insulation voltage (Ui) 300 V
Conditional short-circuit current 100 A with a 10 A gI or gG fuse
Weight Approx. 82 g for a 1-conduit D4N-1120; 99 g for a 2-conduit D4N-5120

Data are from the manufacturer D4N datasheet. The datasheet lists approvals and temperature limits; confirm these for the exact model before using it in a certified machine.

How the D4N-4120 works

A limit switch changes its contact state when the actuator is moved by a cam or door. In the D4N the roller or plunger moves an internal plunger that operates the contact block. The datasheet describes a direct opening mechanism: if the NC contacts weld together, pushing the plunger forces them apart, which is why the NC contact is used in the safety circuit.

The contact form matters. For 1NC/1NO snap-action, the datasheet marks which terminals have approved direct opening, and the other terminals are the auxiliary contact. Wire the safety circuit only through the contact terminals identified as direct opening.

The head can be rotated in four directions, and a hinged cover makes wiring and maintenance easy. Gold-clad contacts allow the same switch to handle microloads, although once a contact has switched a standard load it should not be used for small loads.

Where the D4N-4120 fits and related part numbers

The D4N range uses a model code of conduit, contact and head, giving many combinations. Related codes include D4N-4A62, D4N-412G, D4N-4132 (roller plunger), D4N-1120 (Pg13.5 conduit version). Contact form 1NC/1NO, 2NC, 2NC/1NO and 3NC are all offered, with slow-action and snap-action versions and models with make-before-break contacts.

Typical companions are a G9SA safety relay unit, which monitors the NC channels, and guard-door cams or actuators. The datasheet advises M20 conduit for equipment exported to Europe and 1/2-14NPT for North America.

Selection and ordering checklist for D4N-4120

  • Pick the actuator head that matches how the cam or door moves: resin roller lever (resin lever, resin roller).
  • Choose snap-action or slow-action contacts to suit actuator speed.
  • Check the contact form and which terminals are direct opening.
  • Choose conduit size and thread: M20 conduit, 1-conduit.
  • Check the load against 3 A at 240 V (AC-15) and 0.27 A at 250 V (DC-13).
  • Plan a 10 A gI or gG fuse as short-circuit protection.
  • Consider mounting position and dust or wash-down exposure.

Installation, commissioning and maintenance of the D4N-4120

Fix the switch on a rigid frame so the actuator is only operated by the intended cam or door, not by overtravel. Rotate the head to the required direction, open the hinged cover, wire the terminals and seal the conduit entry to preserve the IP67 rating.

At commissioning, check that the NC contact opens with positive action and that the actuator is not pushed beyond its stroke. Verify that the contact terminals used in the safety circuit are the direct opening ones.

Maintenance includes visual checks of the head and lever, checking that the cover screw is tight, and testing the contact function periodically. Replace the switch if the roller or lever is worn or if the contacts have reached their expected life.

Typical applications in Oman and the GCC

Limit and guard-door switches work in plants in Oman and the GCC from packaging halls to desalination pump stations, exposed to heat, dust and humidity. The sealed IP67 housing and hinged cover of the D4N-4120 are helpful for maintenance in such conditions. The datasheet warns against places where dust, oil, water or chemicals may enter through the head, so choose a suitable seal and conduit.

  • Guard-door position detection on small machines.
  • Cam-operated limit detection on conveyors and lifts.
  • Sliding-door closed confirmation on enclosures and cabinets.

D4N family comparison

Model Actuator Contacts Conduit
D4N-4120 Resin roller lever 1NC/1NO snap M20
D4N-4A62 One-way roller arm (horizontal) 1NC/1NO slow M20
D4N-412G Adjustable roller lever, form lock 1NC/1NO snap M20

The D4N-4120 row shows how it differs from its siblings in actuator and contact action.

Information to send with an RFQ for D4N-4120

  • Full part number D4N-4120 and quantity.
  • Mounting direction and actuator travel.
  • Load voltage and current.
  • Conduit thread requirement.
  • Safety standard and certification requirement.
  • Operating environment.

Documents and quotation

The manufacturer datasheet for the D4N series is attached on this page, including ordering tables and dimensions relevant to D4N-4120.

Send the part number, quantity and delivery point and Seven Star LLC will confirm availability. We are an independent supplier and not affiliated with the manufacturer.

Other Models in the Omron D4n Limit Switches Range

Seven Star LLC supplies models from the Omron D4n Limit Switches range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Omron D4N-4120 Safety Limit Switch resin roller leverSafety Switches & Guard LockingYou are viewing this model
Omron D4N-4A62 Safety Limit Switch one-way roller armSafety Switches & Guard LockingView details
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Omron is a Japanese electronics and automation company, founded in 1933 in Osaka by Kazuma Tateisi and now headquartered in Kyoto. Its industrial automation business makes PLCs, I/O, sensors, relays, safety components, motion control and robots. Omron's CJ and NX series controllers and I/O units are widely used in machine building.

Seven Star LLC lists Omron PLC input and output units from the CJ and NX series and supplies them to panel builders and maintenance teams in Oman.

Omron company profile

Founded 1933, Osaka, Japan
Founder Kazuma Tateisi
Headquarters Kyoto, Japan
Business Industrial automation, healthcare, electronic components
Product families CJ1/CJ2 PLCs and I/O units, NX and NJ controllers, NX I/O, E2E proximity sensors, G2R and MY relays

Omron CJ-series and NX-series units listed here

Three I/O units are on this page. The CJ1W-ID211 is a CJ-series 16-point 24 VDC input unit and the CJ1W-OC211 is a CJ-series 16-point relay output unit. The NX-ID5442 is an NX-series 16-point 24 VDC digital input unit for PNP wiring, 12 mm wide with push-in terminals. CJ and NX units belong to different hardware platforms and do not plug into each other's racks.

Omron products we list

Family Examples
PLC & I/O Cards CJ1W-ID211 CJ-Series 16-Point 24 VDC Inp…, CJ1W-OC211 CJ-Series 16-Point Relay Outp…, NX-ID5442 NX-Series 16-Point Digital Inp…

Ordering Omron PLC modules: what we need

Send the complete model number from the front or side label of the unit, including every suffix. If you are replacing a failed card, add the CPU or coupler model it is mounted with, and tell us if the terminal block or connector is needed as well. For obsolete Omron PLC parts we check which successor the manufacturer documents. Requests from other GCC countries are handled the same way.

Facts checked against Omron's published company history, October 2026.

FAQ

Questions about the Omron D4N-4120 Safety Limit Switch resin roller

Answers from our engineering team on installation, compatibility and integration.

01What does the D4N-4120 model code mean?
D4N is the miniature safety limit switch family. In D4N-4120, the first digit selects the conduit (M20 conduit, 1-conduit), the second the built-in switch (1NC/1NO snap-action) and the rest the head (resin roller lever (resin lever, resin roller)).
02What are the electrical ratings of the D4N-4120?
The datasheet gives AC-15 rated operating current 3 A at 240 V and DC-13 0.27 A at 250 V, with a 10 A thermal current. A 10 A gI or gG fuse is recommended for short-circuit protection.
03Is the D4N-4120 snap-action or slow-action?
It has 1NC/1NO snap-action contacts. Snap-action contacts switch quickly independent of actuator speed, while slow-action contacts follow actuator motion and have a larger contact gap.
04What protection rating does the D4N-4120 have?
The switch is rated IP67 under EN 60947-5-1. The datasheet cautions against use where dust, oil, water or chemicals may enter through the head.
05How many operations will the D4N-4120 last?
Mechanical durability is at least 15,000,000 operations, and electrical durability is at least 500,000 operations at a 3 A, 250 VAC resistive load, measured under standard test conditions.