Brand:

Bürkert 134103 Type 6011 Stainless Miniature Solenoid Valve

Description

Overview

Analytical equipment often needs a small valve whose wetted parts resist more than brass can, and Bürkert 134103 is the stainless version of the Type 6011 miniature. It is a direct-acting normally closed 2/2-way solenoid valve with a G⅛ port, a 1.6 mm orifice, 0.06 m3/h water Kv and a 24 V DC coil. The body is stainless steel 1.4305. Seven Star LLC is an independent supplier serving Oman and the GCC.

Data table for Bürkert 134103

Parameter Value
Article 134103, stainless steel body, G 1/8
Body Stainless steel 1.4305 (analytical variant: brass or stainless steel)
Orifice and Kv 1.6 mm, 0.06 m3/h
Voltage 24 V DC
Pressure range 0 to 6 bar
Family Bürkert Type 6011, direct-acting 2/2-way plunger valve
Circuit function A, normally closed
Seal FKM
Coil Epoxy, thermal class H, tolerance plus or minus 10 percent
Duty cycle 100 percent for a single valve
Medium Technical vacuum, neutral gases and liquids
Medium temperature minus 10 to plus 100 degrees C
Viscosity max. 21 mm2/s
Ambient temperature max. plus 55 degrees C
Electrical connection Plug contacts form C, DIN EN 175301-803, for cable plug Type 2516
Protection IP65 with cable plug
Weight approx. 125 g

Stainless against brass: Bürkert 134103 versus Bürkert 134071

The ordering chart lists the same orifice, Kv, voltage and pressure range for both, so the choice rests on the medium. Stainless steel resists chlorides, mildly acidic or alkaline media and cleaning fluids that attack brass. The analytical variant of the family, intended for neutral or aggressive media, is built with brass and stainless steel only, with no polyamide parts in the flow path, and the 24 V DC and 230 V 50 Hz voltages are the ones offered for that variant. 134103 carries the plain stainless body.

Fluids and compatibility checks

The standard variant handles technical vacuum, neutral gases and liquids such as compressed air, water and hydraulic oil, within minus 10 to plus 100 degrees C and a viscosity of up to 21 mm2/s. The analytical variant, which uses brass and stainless steel only, is meant for neutral or mildly aggressive media that do not attack the body and seal materials. Because the seal is FKM, check compatibility with amines, hot water and certain ketones before specifying the valve, and use a filter upstream of the small orifice to protect it from particles.

Life expectancy and spares

Direct-acting plunger valves typically run for millions of cycles on clean media, but the small orifice makes them sensitive to deposits. Hold at least one spare per critical analyser or dosing line, store it in its bag away from heat, and replace rather than repair when leakage develops. Keep a log of the number of cycles on automatic sampling systems so that valves can be changed on a schedule, and keep spare cable plugs because the plug seal is the first part to fail in dusty or hot installations.

Coil heating and mounting position

Even a small coil warms up in continuous duty. Epoxy class H insulation tolerates it, but nearby plastic parts and tubing may not. Leave space around the coil, keep the valve out of hot enclosures where practical and mount it with the actuator upright, which the data sheet describes as the preferred position. In block mounting, the duty cycle must be reduced or a lower power coil used, so check the data sheet before stacking many valves in a manifold.

Applications

Stainless miniature valves are used in water analysis panels, sampling of boiler water, marine and desalination analysers, laboratory dosing and medical gas panels. They also serve for sensor flushing and cleaning cycles in process instrumentation where brass would corrode.

Care of the valve

Flush the sampling line before first use and avoid solids. After switching to cleaning chemicals, purge with clean water. Replace the valve when response time lengthens or when leakage appears. Record the article number from the coil label for reorder.

Cleaning and purging with Bürkert 134103

Stainless steel miniature valves in analytical service are cleaned by flushing with clean water, a mild detergent or an alcohol, according to the process. The FKM seal tolerates many solvents but not all, so check the compatibility before using aggressive cleaning fluids. After cleaning, purge with dry gas and cycle the valve a few times to dry the seat. Do not use grease, oil or silicone on threads or seals, because the data sheet specifically excludes them as installation aids.

In sampling systems, a valve that holds residue of the previous sample can contaminate the next one, so choose a flush sequence that rinses the seat.

What to include in an RFQ for Bürkert 134103

State the article number, the quantity, the medium and its temperature, the pressure, and the cable plug type. Mention whether the valve is for an analyser panel or a process line, and whether any special cleaning or certification is required for the instrument. We will confirm the availability and delivery time to Oman and the GCC.

Compatibility reminders for Bürkert 134103

A stainless body does not make the seal compatible. FKM has limits with hot water, amines and some ketones. For such media ask about alternative seal materials on request, as the data sheet notes that other variants are available on request.

Delivery notes for Bürkert 134103

The stainless valve is supplied with coil and FKM seal but no cable plug, and the data sheet is attached to this page. Store it dry with port caps in place. Provide any special requirements such as cleaning for oxygen service or traceability documents when you request a quotation, so that they can be arranged before shipment to your site in Oman or the GCC.

Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | Bray 600250-21540536 Series 60 Solenoid Valve 24 VDC Low Power | All Bürkert products.

Documents and quotation

The Type 6011 data sheet containing Bürkert 134103 is attached with dimensions and ordering charts. Send an RFQ with part number 134103, quantity and delivery location in Oman or the GCC.

Other Models in the 6011 Range

Seven Star LLC supplies models from the 6011 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bürkert 134071 Type 6011 Brass Miniature Solenoid ValveSolenoid ValvesView details
Bürkert 134103 Type 6011 Stainless Miniature Solenoid ValveSolenoid ValvesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Bürkert 134103 Type 6011 Stainless Miniature Solenoid Valve Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 134103 Type 6011 Stainless Miniature

Answers from our engineering team on installation, compatibility and integration.

01What body material has Bürkert 134103?
It has a stainless steel body, the stainless counterpart of brass article 134071 with the same orifice and Kv value.
02What is the orifice size of 134103?
The orifice is 1.6 mm, giving a water Kv value of 0.06 m3/h at the G 1/8 port.
03What coil voltage does Bürkert 134103 use?
This article is the 24 V DC version with a pressure range of 0 to 6 bar.
04Can 134103 be used for aggressive media?
The analytical variant is meant for neutral or aggressive media that do not attack the body and seal materials; check the FKM seal compatibility.
05Is Bürkert 134103 supplied with a cable plug?
No. It is supplied with coil and FKM seal but without a cable plug.