Brand:

Meinberg LANTIME M600 High-End 1U NTP Time Server

Description

Overview

Meinberg LANTIME M600 is a one-unit, 19-inch NTP time server that the manufacturer calls its high end NTP time server. It carries an integral Meinberg reference clock, which means the unit does not depend on a network clock to discipline itself: a GPS or combined GNSS receiver is the time source, and every timing output on the chassis follows from it. The front panel combines a vacuum fluorescent display with a keypad so an engineer standing at the rack can read the status of the receiver and of the NTP service without opening a browser.

The model is listed by the maker as no longer available and as replaced by the LANTIME M1000 family. Support continues for units already installed, which is why buyers in Oman still ask for this server when a utility, refinery or telecom room needs a like-for-like unit or a spare. Seven Star LLC is an independent supplier serving Oman and the GCC.

Main characteristics of Meinberg LANTIME M600

  • Selectable reference sources: GPS receiver, a combined GPS, GLONASS, Galileo and BeiDou receiver (GNS), or a multi reference source (MRS) using GPS, PPS, 10 MHz and NTP in priority order.
  • High quality OCXO oscillator fitted as standard to meet holdover requirements; the datasheet states that a TCXO is not available for the M600.
  • Four independent network interfaces as standard, with an option for one 10/100 Mbit management port plus three gigabit ports.
  • Web interface, console configuration utility and full SNMP v1, v2c and v3 support with traps.
  • Alert notification by email, WinMail, SNMP or an external display.
  • USB port on the front panel for firmware updates, backup and restore, key copying and front-panel lock.

Specification table for LANTIME M600

Form factor 19 inch multipac metal case, 1U
Display Vacuum fluorescent display, 256 x 64 dots
Control elements Eight push buttons
Status indicators Four bicolor LEDs: reference time, time service, network link, alarm
Network interfaces, standard 4 x 10/100 Mbit RJ45
Network option 1 x 10/100 Mbit and 3 x 10/100/1000 Mbit RJ45
Serial interfaces Two independent RS-232, menu configurable
Frequency outputs 10 MHz and synthesizer 1/8 Hz to 10 MHz, BNC, TTL into 50 ohm
Pulse outputs PPS and PPM, BNC, TTL into 50 ohm, 200 ms pulse width, active high
IRIG AM output 3 Vpp (mark), 1 Vpp (space) into 50 ohm
Alarm output Relay changeover contact
Power consumption 30 W
Supply voltage 100 to 240 V AC, 50/60 Hz; DC variants 100-200 V DC, 12 V DC, 20-60 V DC
Operating temperature 0 to 50 degrees Celsius
Storage temperature minus 20 to plus 70 degrees Celsius
Humidity Maximum 85 percent, non-condensing, at 40 degrees Celsius
Operating system of the SBC Linux with nano kernel including PPSkit
Warranty Three years

Protocols and time formats of the M600

The server answers NTP versions 2, 3 and 4 and SNTP versions 3 and 4, with MD5 authentication and Autokey key management, and it also supports the Time protocol of RFC 868. For power utilities, the datasheet notes that IEC 61850 compliant devices can be synchronized using SNTP. Management uses HTTP, HTTPS, SSH (including SFTP and SCP), Telnet, FTP, syslog and SNMP over IPv4 and IPv6, with DHCP and DHCPv6 autoconfiguration. On the serial side the unit can send the Meinberg standard string, SAT, Uni Erlangen, SPA, Racal, Sysplex, NMEA 0183 (RMC, GGA, ZDA), Computime and ION strings at baud rates from 300 to 19200.

The timecode generator choices are wide: IRIG B002, B122, B003, B123, B006, B126, B007 and B127, plus IEEE 1344, C37.118 and AFNOR NF S 87-500. These are the formats used by protection relays, disturbance recorders and phasor measurement equipment in substations.

Where Meinberg LANTIME M600 fits in Oman and the GCC

Typical deployments are a control room or substation communications cabinet that must provide traceable time to SCADA servers, historians, protection relay gateways and data loggers. Refinery and gas plant control networks use an NTP server like this so alarm and sequence-of-event timestamps agree across DCS, ESD and fire and gas systems. Telecom rooms and data centres use the same class of device to support logging and billing. With the 1100 m antenna downconverter option from the included GPSANTv2 antenna, the receiver can be mounted on a roof while the rack sits deep inside a building.

How LANTIME M600 differs from other LANTIME models

Compared with the compact LANTIME M150, M250 or M450, the M600 uses a 1U case with a VF display and OCXO as standard. Compared with the modular three-unit M900, it has a fixed hardware layout, and the datasheet points to the M900 for a rubidium oscillator when higher holdover performance is demanded. Its replacement named by the maker is the LANTIME M1000 family, so a project that needs a currently produced unit should discuss that route.

Installation and commissioning

Mount the chassis in a 19-inch rack, connect the supply, fit the antenna with its pre-assembled cable and give the receiver a clear view of the sky. Configure the management port from the front panel buttons, then use the web interface to set NTP options, authentication, SNMP community strings and notification targets. The alarm relay can be wired into a plant monitoring system so that loss of synchronization raises an alarm.

Maintenance

Keep a copy of the configuration on a USB stick through the front port, check the antenna cable and lightning protection once a year, and read the alarm log after power events. Firmware updates are provided free for the lifetime of the product and can be installed from the unit directly.

Ordering notes

Because the unit is built to order, please state the receiver type (GPS, GNS or MRS), oscillator, supply voltage, network option and any extra outputs such as IRIG or synthesizer when you send your enquiry.

Related items you may also need: Meinberg GNMANTv2 Dual-Band Multi-GNSS Antenna, IP65 | Meinberg LANTIME M450 DIN Rail NTP Time Server | Meinberg LANTIME M500 Modular DIN-Rail Time Server | All Meinberg products.

Checklist before ordering the Meinberg LANTIME M600

  • Before ordering the Meinberg LANTIME M600, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
  • Our team confirms the Meinberg LANTIME M600 code, condition and lead time in writing before any order is placed.
  • The datasheet attached to this page is the reference for the Meinberg LANTIME M600 dimensions, ratings and wiring.
  • The Meinberg LANTIME M600 is listed in our industrial communications range and ships to sites across Oman and the GCC.
  • Spare quantities of the Meinberg LANTIME M600 are worth planning for critical duty so that a failure does not stop production.

Documents and quotation

The manufacturer datasheet for Meinberg LANTIME M600 is attached to this page. To obtain a quotation, send an RFQ with the part number Meinberg LANTIME M600, your required configuration and quantity.

Datasheets & Documents
  • PDF Datasheet Meinberg LANTIME M600 High-End 1U NTP Time Server Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Meinberg is a German maker of time and frequency synchronisation products, founded in 1979 by the brothers Werner and Günter Meinberg in Bad Pyrmont. It began with DCF77 longwave radio clock receivers and now makes GPS and GNSS-referenced NTP and PTP time servers. Meinberg is family-owned and designs and manufactures its products in Bad Pyrmont.

Seven Star LLC sources and supplies Meinberg LANTIME time servers for utilities and networks in Oman, including the M1000 and M320 listed here.

Meinberg company profile

Founded 1979, Bad Pyrmont, Germany
Founders Werner and Günter Meinberg
Ownership Family-owned
Manufacturing Bad Pyrmont, Germany
Product families LANTIME M150, M250, M320, M500 and M1000 NTP/PTP time servers, IMS modular systems, GNSS and DCF77 receivers, PTP grandmaster clocks

Meinberg LANTIME models listed here

The LANTIME M320 is a 1U rackmount NTP time server. It works as a stratum 1 source with its own reference receiver, and Meinberg offers it with GPS, combined GNSS, DCF77 (PZF), MSF and IRIG time code references. The LANTIME M1000 is a 1U platform on the modular IMS system, with slots for up to two reference clocks, two power supplies and hot-pluggable I/O modules, plus PTP (IEEE 1588) and IEC 61850 time synchronization.

Meinberg products we list

Family Examples
Industrial Communications LANTIME M1000 Modular NTP/PTP Time Serve…, LANTIME M150 DIN-Rail NTP Time Server, LANTIME M250 Compact NTP Time Server, LANTIME M320/GPS/AD10 NTP Time Server, LANTIME M500 Modular DIN-Rail Time Server

Ordering a Meinberg time server: what we need

A Meinberg order code describes the build. In M320/GPS/AD10, GPS is the receiver and AD10 is the wide-range AC/DC power supply. Send the full code or serial number, the reference source, oscillator option, supply voltage, the outputs you need (PPS, 10 MHz, IRIG, extra LAN ports) and the antenna cable length. GCC utility projects often require redundant supplies.

Facts checked against Meinberg's own company history (meinbergglobal.com), October 2026.

FAQ

Questions about the Meinberg LANTIME M600 High-End 1U NTP Time Server

Answers from our engineering team on installation, compatibility and integration.

01Is the Meinberg LANTIME M600 still produced?
The maker lists it as no longer available and replaced by the LANTIME M1000 family; support continues for units already in service.
02Which reference sources can the LANTIME M600 use?
It can use a GPS receiver, a combined GPS, GLONASS, Galileo and BeiDou receiver, or a multi reference source mixing GPS, PPS, 10 MHz and NTP.
03What oscillator does the LANTIME M600 have?
An OCXO LQ oscillator is standard. The datasheet states that a TCXO is not available, and higher OCXO grades are options.
04How many network ports does the LANTIME M600 have?
Four independent 10/100 Mbit RJ45 ports as standard; an option provides one 10/100 Mbit port and three gigabit ports.
05Can the LANTIME M600 output IRIG time code?
Yes. The datasheet lists IRIG B002, B122, B003, B123, B006, B126, B007 and B127, IEEE 1344, C37.118 and AFNOR time code formats.