- Automation & ControlView all 3,095 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Metrohm
Metrohm 815 Robotic USB Sample Processor XL Autosampler
Description
Overview
Where a simple sample changer stops at the beaker, the Metrohm 815 Robotic USB Sample Processor XL keeps going: its robotic arm can pick up an aliquot, move it to a separate titration cell, add solvent or auxiliary solution, and clean up while the next sample is already being prepared. Metrohm positions the XL as the answer for large sample series that need preparation as well as analysis, with parallel working so that dead time between steps is minimised. Seven Star LLC is an independent supplier serving Oman and the GCC.
Because the specification of the turntable, lift and electronics is shared with the 814, the real difference lies in the swing heads and robotic arms that can be mounted. This page explains those options so that you can list the exact configuration in your request.
Capabilities of this robotic sample processor
- Automatic sample preparation, including pipetting and liquid handling.
- Parallel preparation and analysis: while one sample is titrated, the next one is prepared.
- Combination with the 786 Swing Head and a robotic swing arm to reach every position of the rack.
- Three MSB sockets for additional dosing burets and stirrers.
- Control by tiamo or MagIC Net software, or stand-alone through the touch panel of a Touch Control.
- Automatic rinsing with built-in membrane pumps or external peristaltic pumps.
Metrohm 815 Robotic USB Sample Processor XL data table
| Parameter | 815 XL value |
|---|---|
| Configurations | 2.815.0010 (1T/1P), 0020 (1T/2P), 0030 (1T/0P), 0110 (2T/2P), 0120 (2T/4P), 0130 (2T/0P) |
| Lift stroke | 235 mm, load approx. 30 N |
| Lift rate | 5 to 25 mm/s, adjustable |
| Turntable speed | 3 to 20 degrees per second, adjustable |
| Membrane pump | Above 450 mL/min, 2 m pressure head |
| MSB connectors | Three 9-pin Mini DIN sockets |
| USB downstream ports | Two, 500 mA each |
| Pump connectors | Two M8 sockets, 16 V, up to 0.8 A |
| Rod stirrer speed | 180 to 3000 rpm |
| Power | 100 to 240 VAC, 50 to 60 Hz, 115 W |
| Size | 0.28 m wide, 0.73 m high, 0.53 m deep |
| Weight | 0010: 14.52 kg; 0110: 18.87 kg; 0120: 19.93 kg |
How Metrohm 815 Robotic USB Sample Processor XL differs from 814
Both devices share the lift stroke of 235 mm, the turntable speeds and the 115 W power consumption, and both come in six versions with the same weight figures. The 815 is 0.53 m deep against 0.50 m for the 814, and its main distinction is functional: it works with the Robotic Swing Arm and the 786 Swing Head, which let it transfer aliquots and work with an external titration cell. The 814 titrates or measures directly in the sample beaker. Racks also differ: the 815 racks hold 28 x 250 mL, 28 x 200 mL, 34 x 150 mL, 59 x 120 mL or 100 x 75 mL, which is more beakers than the equivalent 814 racks for the same vessel size, and a 228 x 11 mL rack with two 300 mL positions is available. Some 815 racks require the water bath 6.2840.000.
Swing heads, arms and heads
The 786 Swing Head exists as a robotic transfer arm (left or right), as a robotic titration arm (left or right) and as a plain swing head. Separate robotic swing arms include a transfer arm in left and right versions, a titration arm, titration head holders and a Dis-Cover. Titration heads are offered with six NS14 and three NS9 openings, two M10, four M10 for Karl Fischer applications, three NS14, or two NS14 plus one M10. Several of the arms are also available with a beaker sensor. List the code you need.
Sample preparation use cases in Oman and the GCC
Environmental and industrial water laboratories can pipette a defined aliquot into a titration cell, adjust it with an auxiliary solution and titrate for alkalinity, hardness or chloride while the arm prepares the next sample. Petrochemical and lubricant laboratories use the same logic for acid number and water by Karl Fischer, provided the KF titration head is selected. Food and beverage producers use direct measurements of pH and conductivity in the beaker followed by titration in the cell. Throughput matters in contract laboratories, where hundreds of samples arrive each week.
Planning throughput and the sequence of steps
The maker illustrates a simple analysis with optimised time like this: the samples are placed on the rack, the electrode measures directly in the sample, for example pH or conductivity, an aliquot is transferred into the external titration cell, solvent or an auxiliary solution is added, the titration or measurement runs, and while this happens the arm prepares the next sample transfer and measures directly in the following sample. Afterwards the solutions are disposed of, the electrode is cleaned and conditioned and the results are evaluated. Because preparation of sample two overlaps with titration of sample one, the arm can keep the titration cell busy without waiting for manual work between samples. When you size an installation, compare the number of samples per shift with the rack capacity so that the rack does not run dry in the middle of a series, and consider using two work stations when the methods need different electrodes or solvents.
Rack selection for large series
The 815 racks range from 15 x 250 mL positions on the water bath to 228 x 11 mL vials with two 300 mL beakers for rinsing or conditioning. Typical glass beakers are 75 mL, 120 mL, 150 mL, 200 mL and 250 mL, and polypropylene beakers are available in the same classes plus 11 mL and 15 mL vials and 50 mL tubes. The standard racks accept ordinary glass, plastic and disposable vessels, which keeps consumable cost under control. If the beaker size you use is not listed, Metrohm will devise a custom solution, so provide the diameter and height. The water bath 6.2840.000 is an optional extra that can only be fitted together with the collection trough 6.2711.070; racks marked with an asterisk in the brochure are meant for the water bath only. Check these notes before selecting a rack code because a mismatch is the most common reason for a delayed commissioning.
Installation and set-up
Allow space for the unit, which measures 0.28 x 0.53 m with a height of 0.73 m, plus room for pumps, bottles and waste containers. Connect the controller cable, mount the swing head, connect pumps and attach the rack. Operating conditions are 5 to 45 degrees C with up to 80 percent humidity without condensation, altitude not above 2,000 m and pressure at least 800 mbar. A fuse of 2.0 A time-lag protects the mains input.
Interfaces and peripherals
The rear panel offers a USB upstream port for the computer, two USB downstream ports rated at 500 mA each for Metrohm instruments or third-party USB peripherals such as barcode readers, three MSB sockets for Dosino or Dosimat units and stirrers, a DIN socket for a stirrer, a socket for the swing head and two M8 pump sockets that supply 16 V at up to 0.8 A. The pump sockets accept the 772 Pump Unit, the 823 Membrane Pump Unit or the 843 Pump Station. Stirring speed can be set from 180 to 3000 rpm for the rod stirrers and from 180 to 2600 rpm for the 741 magnetic stirrer in fifteen steps and in both directions of rotation.
Operation and software
Methods are stored in the control software; the analyst places the samples on the rack and enters the sample data, optionally through a barcode reader, and the weight can be transferred directly from a balance. The sample series is then started. The control system interlaces processing steps so that they can run in parallel, and results appear shortly after the final sample is finished.
Care and maintenance
Inspect tubing and fittings regularly, clean the drip pan and collection trough, and rinse pumps after using organic solvents. Calibrate or condition electrodes according to the method. Keep the manual, which includes the rack code table and maintenance chapter, with the instrument.
Ordering notes for the 815 XL
For a correct quotation please state the 815 XL model together with the number of work stations and pumps, the swing head and arm, the rack code and titration heads, plus any dosing units or electrodes. Seven Star LLC can then assemble a complete offer for delivery in Oman and across the GCC.
Related items you may also need: Metrohm 905 Titrando Potentiometric Titrator | Metrohm 2035 Process Analyzer | Metrohm 916 Ti-Touch Compact Potentiometric Titrator | All Metrohm products.
Points to confirm for the Metrohm 815 Robotic USB Sample Processor XL
- If the Metrohm 815 Robotic USB Sample Processor XL is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
- For each Metrohm 815 Robotic USB Sample Processor XL request we confirm the exact code, new or surplus condition and lead time in writing.
- Dimensions, ratings and connection data for the Metrohm 815 Robotic USB Sample Processor XL are in the datasheet attached to this page.
- The Metrohm 815 Robotic USB Sample Processor XL belongs to our liquid analytical systems range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
- Plants that run the Metrohm 815 Robotic USB Sample Processor XL on critical service often hold a spare unit in the store.
Documents and quotation
The brochure for the Metrohm 815 Robotic USB Sample Processor XL is attached as the datasheet. Send your RFQ with the part number Metrohm 815 Robotic USB Sample Processor XL, the quantity and your delivery location, and we will respond with availability and lead time.
Other Models in the Sample Processor Range
Seven Star LLC supplies models from the Sample Processor range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Metrohm 814 USB Sample Processor Automatic Sample Changer | Liquid Analytical Systems | View details |
| Metrohm 815 Robotic USB Sample Processor XL Autosampler | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Metrohm 815 Robotic USB Sample Processor XL Autosampler Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.
Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.
Metrohm company profile
| Founded | 1943, Herisau, Switzerland |
|---|---|
| Founder | Bertold Suhner |
| Headquarters | Herisau, Switzerland |
| Ownership | Metrohm Foundation |
| Product families | Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes |
Metrohm instruments listed here
The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.
Metrohm products we list
| Family | Examples |
|---|---|
| Liquid Analytical Systems | 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr… |
Ordering Metrohm equipment: what we need
Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.
Facts checked against Metrohm's published company history, October 2026.
Browse Metrohm products by category: Liquid Analytical Systems.
FAQ
Questions about the Metrohm 815 Robotic USB Sample Processor XL
Answers from our engineering team on installation, compatibility and integration.
01What makes the Metrohm 815 Robotic USB Sample Processor XL different from the 814?
The 815 works with robotic swing arms and the 786 Swing Head, so it can pipette and transfer aliquots to a separate titration cell, while the 814 works in the sample beaker.
02Which versions of the 815 Robotic USB Sample Processor XL are listed?
Metrohm lists 2.815.0010, 0020, 0030, 0110, 0120 and 0130, which differ in work stations (1T or 2T) and pumps (0P, 1P, 2P or 4P).
03What software controls the 815 Robotic USB Sample Processor XL?
It is controlled by tiamo or MagIC Net software on a computer, or operated stand-alone using the touch panel of a Touch Control.
04What are the dimensions of the 815 Robotic USB Sample Processor XL?
It is 0.28 m wide, 0.73 m high and 0.53 m deep, and the 0010 version weighs 14.52 kg without accessories.
05Can the 815 Robotic USB Sample Processor XL be used for Karl Fischer work?
Yes, a titration head with four M10 openings for KF applications is offered in the brochure, and the processor can then be combined with a KF titrator.


















Reviews
There are no reviews yet.