- Automation & ControlView all 3,171 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: EUCHNER
EUCHNER TP3-2131A024M Guard Locking Switch with Door Contact
Description
Overview
A single housing that reports both the door position and the lock state saves wiring and mounting effort, and that is the point of the EUCHNER TP3-2131A024M. This TP series safety switch locks by spring, releases with a 24 V solenoid and carries a door monitoring contact together with two positively driven and one normally open contact for guard lock monitoring. A reinforced thermoplastic body, an M20 x 1.5 cable entry and IP67 protection complete the package. Seven Star LLC is an independent supplier serving Oman and the GCC.
Reading TP3-2131A024M
TP3 tells you that the switch includes contacts for the door position and is spring locked, while 2131 names the switching element with its contact mix. Door monitoring is a normally closed contact, and lock monitoring supplies two positively driven contacts plus one NO contact. The letter A defines the approach arrangement, 024 the solenoid voltage and M the cable gland. In other words, a controller can see at a glance whether the door is shut and whether the bolt really sits in the actuator, without any additional sensor on the door.
Technical sheet for EUCHNER TP3-2131A024M
| Characteristic | Value |
|---|---|
| Locking principle | Closed-circuit current, spring locked |
| Guard lock contacts | 2 positively driven + 1 NO |
| Door monitoring | NC contact in element 2131 |
| Solenoid | 24 V AC/DC, minus 15 to plus 10 percent, 8 W |
| Contact categories | AC-15 4 A 230 V; DC-13 4 A 24 V; thermal current 4 A |
| Locking force | 1300 N maximum / 1000 N holding |
| Forces | Actuating 10 N; extraction 20 N; retention 10 N |
| Cable entry | 3 x M20 x 1.5 |
| Housing | Reinforced thermoplastic |
| Protection / ambient | IP67 / minus 20 to plus 55 degrees C |
| Overtravel | 7 mm horizontal with the GNT actuator; 2 mm horizontal and 1.5 mm vertical with the GT actuator |
| B10d lock monitoring | 3 million operations; 20 years |
How EUCHNER TP3-2131A024M differs from other TP variants
The TP1 versions have no door contacts, and the TP2 versions lock by power. The TP3-2131A024M combines spring locking with door and lock contacts, so it needs only one cable run per guard. Siblings include the TP3-2131A110M for a 110 V solenoid, the TP3-2131A024SR11 with a connector, the TP3-2131A024L024M with a separate low voltage input, and codes with escape release such as TP3-2131A024MC1743. The standard version described here has no escape release, which suits guards used only from the outside.
Where it fits in Oman and the GCC
Medium-duty doors on packaging, filling, labelling and light assembly machines use this switch to cut cost, since one device replaces a separate door switch. The plastic housing resists corrosion in humid coastal regions, the IP67 rating blocks dust, and the light weight makes it easy to fit on thin frames. OEMs exporting machines to the Gulf often select it as a standard guard lock.
Actuators, mounting and wiring
Pick an actuator from the NP, GP and TP list. Straight, bent and hinged versions exist, as well as rubber bush types and increased overtravel for doors with rubber stops. Position the head so the bolt enters freely and the door sits without constant pressure on the head, adjust the approach direction in 90 degree steps and tighten the fixing screws. Use cable of 0.34 to 1.5 mm2 and a fuse not above 4 A gG. Respect the minimum switching load of 12 V at 10 mA so that the contacts stay reliable.
Checks and maintenance
With the guard open, check that the door contact opens the safety circuit, and with the guard closed and locked check the lock contacts. Test the auxiliary release and keep it sealed against misuse. Examine the actuator for wear and replace the switch after one million operations. The operating instructions also note that a risk assessment is needed and that the switch must not be repaired.
Specifying the EUCHNER TP3-2131A024M
Choose this code when a single housing should report door and lock states with a 24 V spring locked solenoid. State the actuator at the same time and quote the exact code EUCHNER TP3-2131A024M.
Cabling and diagnostics with the EUCHNER TP3-2131A024M
Putting door and lock contacts in one housing cuts the cable count roughly in half compared with using a separate door switch next to a lock-only device. The M20 x 1.5 entry accepts a normal gland, and the terminals take conductors from 0.34 to 1.5 mm2. In a safety controller that evaluates each contact separately, the two positively driven lock contacts can be connected as a two-channel input, the NO contact can be sent to a PLC as a status bit and the door contact can feed the second safety channel. This gives the maintenance team a clear picture: door open, door closed and unlocked, or door closed and locked. The two LEDs fitted to the switch show the state locally, and the signals can be logged for diagnostics and preventive maintenance.
Plan spares early, because lead times for imported safety components can stretch beyond the planned shutdown window. Keep a stock policy for spares. The actuator is the part most likely to be damaged, followed by the switch head itself after heavy slamming of the door. Holding two actuators and one switch for every ten guards is a common rule of thumb in plants that run several shifts, and it avoids production stops while a replacement is sourced from abroad. Write the full ordering code on the spares bin label to prevent the wrong voltage or contact version being fitted in a hurry.
Related items you may also need: EUCHNER ESM-TE301 Time-Delayed Safety Contact Expansion | EUCHNER CTP-I-AP-U-HA-ZZ-SA Safety Switch without Guard Locking | EUCHNER CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety Switch | All EUCHNER products.
Documents and quotation
The TP operating instructions are attached to this page and describe installation, wiring and safety values. Please send your RFQ with EUCHNER TP3-2131A024M, the quantity and your delivery location in Oman or the GCC.
Other Models in the Tp Range
Seven Star LLC supplies models from the Tp range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| EUCHNER TP1-538A024M Spring-Locked Guard Locking Switch | Safety Switches & Guard Locking | View details |
| EUCHNER TP2-528A024M Guard Locking Switch, Power Lock | Safety Switches & Guard Locking | View details |
| EUCHNER TP3-2131A024M Guard Locking Switch with Door Contact | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet EUCHNER TP3-2131A024M Guard Locking Switch with Door Contact Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER TP3-2131A024M Guard Locking Switch with
Answers from our engineering team on installation, compatibility and integration.
01What does the TP3 in EUCHNER TP3-2131A024M mean?
TP3 denotes the spring locked TP version with a door position contact in addition to the guard lock monitoring contacts.
02What contacts are fitted in the TP3-2131A024M?
The 2131 element provides a door monitoring NC contact and, for lock monitoring, 2 positively driven contacts plus 1 NO contact.
03What is the locking force of the TP3-2131A024M?
The product page states 1300 N maximum locking force and 1000 N holding force.
04What supply voltage does the TP3-2131A024M use?
It uses a 24 V AC or DC solenoid, minus 15 to plus 10 percent, with 8 W power consumption and 100 percent duty.
05How does the TP3-2131A024M differ from the TP1-538A024M?
The TP3 adds a door position contact and has a 2131 element, whereas the TP1 offers lock monitoring only with a 538 element.


















Reviews
There are no reviews yet.