Magnetrol C24-1B10 is the compact cast iron float chamber level switch in the C24 and C25 series, offered for general industrial liquid level duty rather than boiler service. Its chamber carries no brass liner, which is the feature that separates the C models from the B models used on steam boilers. A float inside the chamber raises a magnetic attraction sleeve into the field of a pivoted switch magnet, and the switch sits outside the pressure boundary. Seven Star LLC is an independent supplier serving Oman and the GCC.

What the 1B10 code stands for

In the datasheet the suffix 1B10 identifies a cast iron chamber with a 400 series stainless steel attraction sleeve, a 316L stainless steel float and 316 stainless steel trim. The minimum specific gravity is 0.84. The chamber is limited to 250 psi at 406 F (17 bar at 207 C), and the maximum pressure at 100 F is 400 psi (28 bar). Because cast iron limits service temperature to 406 F, the switch mechanism rating is only relevant if it is lower.

Magnetrol C24-1B10 data table

Chamber Cast iron, no liner (non-boiler service)
Attraction sleeve 400 series stainless steel
Float 316L stainless steel
Trim 316 stainless steel
Minimum specific gravity 0.84
Working pressure 250 psi at 406 F (17 bar at 207 C)
Maximum pressure at 100 F 400 psi (28 bar)
Switch capacity Up to three switch mechanisms in the family; single mechanism for the quoted actuation levels
Electrical conduit 1 inch NPT
Pneumatic connection 1/4 inch NPT
Enclosure TYPE 4X/7/9 aluminum for Class I Division 1 Groups C and D, or Group B
Process temperature Up to +1000 F (+538 C) per switch type, but limited by cast iron to 406 F

Actuation levels for Magnetrol C24-1B10

Datasheet actuation levels apply to a single switch mechanism with fluid of specific gravity 1.0 and have a tolerance of plus or minus 0.25 inch (6 mm). For the C24 they are 0.69 inch (18 mm), 1.56 inch (40 mm), 0.94 inch (24 mm) and 1.69 inch (42 mm); these are the four dimensions given in the datasheet actuation table. This narrow band makes the C24 suitable for an alarm that needs to trip near the centerline of a small vessel.

How C24-1B10 differs from C25-1B10

The two codes share the same materials and the same 250 psi at 406 F rating. The difference is the chamber height. The C25 raises the actuation levels to 3.69, 4.50, 4.13 and 4.88 inches (94, 114, 105 and 124 mm), giving a wider spacing between switching points. The C25 body is also taller, as its dimension drawing shows. Pick the C24 for a short span on small vessels and the C25 when more differential is needed.

Switch mechanisms available

Dry contact Series B, C and D switches, hermetically sealed Series F and HS switches, and pneumatic Series J and K switches are offered. The electrical codes for the C24 include BKP for a Series B SPDT in a Groups C and D housing, and CKP for Series C. At 120 VAC the non-inductive ratings are 15 A for Series B and C, 10 A for D and 2.5 A for F. Pneumatic codes include JDE and KOE, with maximum supply pressures of 100 psig for Series J with the smallest orifice and up to 40 psig for the non-bleed K type.

Float chamber principle and design details

A permanent magnet is attached to a pivoted switch actuator with an adjustment screw. As the float rises with the liquid, it lifts the attraction sleeve into the field of the magnet, which snaps against the non-magnetic enclosing tube and operates the switch. The enclosing tube forms a static pressure boundary between the switch mechanism and the process. On a falling level an Inconel spring retracts the magnet and the switch resets.

The chamber has a removable cover for easy inspection of the float, and right or left hand water column mounting, try cock tappings and sight glass tappings are offered on the related water column models. Up to three switch mechanisms can be fitted to give alarm, control and shutdown functions from one chamber.

Because cast iron is brittle compared with steel, avoid thermal shock, water hammer and hard pipe strain at the connections; support the adjoining pipework independently. Use a relief device on the vessel as required by the plant code, since the chamber rating is a working limit and not a protective device.

Where it fits

Condensate receivers, flash tank high level alarms, day tanks, holding tanks and feedwater pump control are all listed in the datasheet as applications. In Oman and Gulf plants this switch suits industrial boiler house condensate tanks, process water break tanks and low pressure steam drums, provided that the cast iron limits are respected.

Installation, commissioning and care

Mount the chamber upright with the connections level to the vessel taps and allow 10 inches of overhead for cover removal. Check that the vessel cannot exceed 250 psi at 406 F. After wiring, test by varying the level. Inspect the chamber and float periodically for sludge and scale, and verify the switch contacts under load. Record the switching levels in the loop folder so that any later drift in the set points can be spotted during routine proof tests and corrected before it affects the process. When ordering spares, confirm the full order code on the nameplate.

Related items you may also need: Magnetrol 089-7250-004 8A DPDT AC Remote Electronics Module, Thermatel | Magnetrol 089-7250-002 8A DPDT AC Electronics Module for Thermatel TD2 | Magnetrol Z30-9165-001 HART Wiring Board for Eclipse 706 and Pulsar | All Magnetrol products.

Magnetrol C24-1B10 ordering checklist

  • When the Magnetrol C24-1B10 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
  • Every enquiry for the Magnetrol C24-1B10 is answered with a written confirmation of the code and expected lead time.
  • Use the attached datasheet to check the Magnetrol C24-1B10 ratings, dimensions and connection details against your drawings.
  • We supply the Magnetrol C24-1B10 as part of our level switches range to plants in Oman and the GCC.
  • For critical duty, keeping one Magnetrol C24-1B10 as a site spare shortens downtime after a failure.

Documents and quotation

The datasheet for Magnetrol C24-1B10 is attached. Please send your RFQ to Seven Star LLC with the suffix 1B10, switch and enclosure code, any pneumatic option and the quantity required.

Datasheets & Documents
  • PDF Datasheet Magnetrol C24-1B10 Cast Iron Float Chamber Level Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol C24-1B10 Cast Iron Float Chamber Level

Answers from our engineering team on installation, compatibility and integration.

01What is the difference between the C24 and the B24?
The C models have no chamber liner and are for general industrial use, while the B models include a brass inner liner for boiler service.
02What pressure rating does C24-1B10 have?
The datasheet gives 250 psi at 406 F (17 bar at 207 C) working pressure, with 400 psi (28 bar) maximum at 100 F.
03What materials make up C24-1B10?
A cast iron chamber, 400 series stainless steel attraction sleeve, 316L stainless steel float and 316 stainless steel trim.
04What minimum specific gravity does the C24-1B10 require?
Its minimum specific gravity is 0.84, so lighter hydrocarbons need a different chamber code or low gravity float.
05How does the C24 differ from the C25?
The C25 chamber is taller, with actuation levels of 3.69 to 4.88 inches against 0.69 to 1.69 inches for the C24.