Brand: MICHELL Instruments
MICHELL Instruments XZR250 Zirconia Oxygen Analyzer 0.1-25% O2
Description
Overview
The MICHELL Instruments XZR250 is a compact zirconium oxide oxygen analyzer built to read percentage oxygen in the flue gas of fired equipment. It reports 0.1 to 25 percent O2, and its 316 stainless steel probe, with a 435 mm insertion length, can sit in gas as hot as 700 degrees Celsius. Sample gas reaches the sensor chamber and returns to the flue through the Pitot effect, so the unit needs no instrument air supply, and the micro ion pump sensor works without an air reference. Seven Star LLC is an independent supplier serving Oman and the GCC.
Michell Instruments, the British humidity and gas measurement company, lists the MICHELL Instruments XZR250 in its oxygen analyzer range as the small, wall-free alternative to larger extractive combustion units. It targets burners and boilers that run on natural gas, light oil, diesel or biomass, where the plant simply needs a dependable excess-air figure to tune the air to fuel ratio.
Key features of the XZR250
- Measures 0.1 to 25 percent oxygen in combustion gas, with output resolution of 0.01 percent O2, 0.01 mA or 0.01 V.
- Barometric pressure compensation keeps the reading honest when the stack draft or weather changes.
- MODBUS over RS485 is fitted as standard, so no option card is required for digital integration.
- Single or dual 4-20 mA analog outputs, with the second loop configurable for a pressure signal or a second oxygen output.
- Two relays: one system alarm and one user configurable process alarm, both supplied as normally open contacts.
- Sensor can be swapped without special tools, and a sensor exchange program is offered by the manufacturer.
MICHELL Instruments XZR250 technical specifications
| Measurement technology | Zirconium oxide, micro ion pump sensor (MIPS), no air reference |
|---|---|
| Gas / range | Oxygen, 0.1 to 25 percent |
| Accuracy (0.1 to 25 percent) | Less than 0.25 percent O2 |
| Response time (T90) | Less than 15 seconds |
| Repeatability | Less than 0.25 percent |
| Sample flow effect | Plus or minus 0.5 percent of full scale |
| Sample cell temperature | 700 C (1292 F), PT100 temperature measurement |
| Sample gas temperature | Up to 700 C; excursions to 750 C for 30 minutes will not damage the probe |
| Sample pressure | 760 to 1260 mbara absolute |
| Warm-up / stabilization | Less than 90 seconds / less than 5 minutes |
| Power supply | 24 V DC, plus or minus 10 percent (limited power source), 700 mA maximum |
| Analog outputs | Single or dual 4-20 mA, 550 ohm maximum loop load |
| Output ranges | O2 0-25 percent; pressure 760-1260 mbara; temperature -50 to +300 C |
| Digital interface | RS485, MODBUS |
| Relays | 1 system alarm and 1 user configurable process alarm, SPST normally open |
| Display | 16 character, 2 line, backlit |
| Head dimensions | 130 x 120 x 150 mm (h x w x d) excluding probe |
| Weight | Head 1.6 kg; probe (stainless steel, 435 mm) 4.8 kg |
| Process connection | 2 inch 150 lb ANSI flange profile (not pressure retaining) |
| Ingress protection / housing | IP65, painted aluminium |
| Wetted materials | Stainless steel, Macor, aluminium, platinum body and PTFE |
| Ambient conditions | -20 to +55 C, 0 to 95 percent RH |
| Cable entry | M12 x 1.5 gland for 7 to 12.5 mm cable with 4 to 11 cores and overall screen |
How the MICHELL Instruments XZR250 measures oxygen without reference air
Most in-situ zirconia probes need a flow of clean air against the reference electrode. The MICHELL Instruments XZR250 uses a micro ion pump sensor that generates its own reference, which removes tubing, filters and compressed air from the installation drawing. Flue gas is pulled into the heated sensor chamber by the pressure difference created across the probe tubes, and the heated cell, held at 700 C, produces a voltage proportional to the oxygen difference. A PT100 element tracks cell temperature so the electronics can correct the reading, and the barometric compensation adjusts for ambient pressure.
Because the datasheet specifies a warm-up of under 90 seconds and stabilization under five minutes, the analyzer comes back into service quickly after a boiler restart. Output resolution is fine enough for burner trim loops, while the less than 0.25 percent accuracy figure makes it suitable for combustion efficiency logs.
Typical applications in Oman and the GCC
The manufacturer positions the MICHELL Instruments XZR250 for combustion control on boilers burning natural gas, light oil, diesel and biomass. In Oman and across the GCC that translates to utility steam boilers at desalination and power sites, package boilers in food and beverage plants, hot oil heaters in petrochemical and refinery units, and diesel-fired heaters at remote oil and gas facilities. Wherever a burner management system needs an excess oxygen signal, a 4-20 mA loop from this analyzer can feed the trim controller directly, and MODBUS values can be logged by a plant historian.
The 700 C sample temperature limit and stainless steel probe make it a flue-duct instrument. It is not intended for corrosive process gas streams or for particulate-heavy furnaces; those duties belong to heavier probe options in the wider Michell oxygen range.
Selection notes: how XZR250 differs from other oxygen analyzers in the range
- MICHELL Instruments XZR250: 0.1 to 25 percent O2, 435 mm probe, Pitot sampling, sample temperature to 700 C, MODBUS standard, 24 V DC.
- XZR200: 0 to 25 or 0 to 100 percent O2, 210 or 400 mm probe of 12 mm diameter, sample temperature to 400 C, response under 5 seconds, RS232 or 4-20 mA with 0-10 V.
- XZR500: 0.01 to 25 percent O2, 0.4, 0.6 or 0.9 m probes in six materials, probe temperatures to 1400 C, separate control unit, 110 or 220 V mains supply.
Choose the MICHELL Instruments XZR250 when the stack gas is below 700 C, a flange connection is acceptable, and the plant wants digital communication without options. Choose a different model when you need the 100 percent range, a ceramic probe or a back-flush facility for dusty gas.
Installation and commissioning
Mount the 2 inch ANSI 150 lb flange on a matching stack nozzle; the datasheet notes that this flange profile is not pressure retaining, so the stack should operate within the 760 to 1260 mbara sample pressure window. Use 24 V DC from a limited power source and size the supply for the 700 mA maximum draw. Route a screened cable of 7 to 12.5 mm outer diameter through the M12 x 1.5 gland. Allow the head to cool before handling: the manufacturer warns that the sensor reaches 250 C and must not be touched without protective equipment. After warm-up, calibrate against a known oxygen concentration, and confirm the relay and loop settings at the display.
Maintenance and service life
The sensor can be exchanged in the field with ordinary hand tools, and the manufacturer runs a sensor exchange program, so routine care is limited to periodic calibration checks, inspecting the cable gland seal and keeping the probe tubes clear of soot. Keep a record of the calibration offset; a steady drift trend is the earliest sign that the cell is approaching the end of its life.
Related products and ordering notes
Dew point, moisture and other oxygen instruments from the same maker are catalogued on this site for plants that standardize on one instrument family. When you request a quotation for MICHELL Instruments XZR250, state the number of analog outputs required, the stack flange size and the supply voltage.
Related items you may also need: Michell EPR-LQ-IS Easidew PRO LQ I.S. Moisture-in-Liquids Transmitter | Michell XTC601-EX1 Explosion-Proof Binary Gas Analyzer | Michell QMA401 Trace Moisture Analyzer | All MICHELL Instruments products.
MICHELL Instruments XZR250 ordering checklist
- When the MICHELL Instruments XZR250 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
- Every enquiry for the MICHELL Instruments XZR250 is answered with a written confirmation of the code and expected lead time.
Details needed to quote the MICHELL Instruments XZR250
The MICHELL Instruments XZR250 is a model family that Michell builds to a configuration, so the orderable unit is fixed by the options below and not by the model name alone.
- Measuring range and the gas or sample the MICHELL Instruments XZR250 will analyse.
- Output signals and communication needed by your control system, for example 4-20 mA, relays or a digital protocol.
- Supply voltage and the mounting style required on site.
- Hazardous area classification of the installation location, if any.
- Sample handling and process connection details, including pressure, temperature and any sampling system or accessories.
Send these details, or the full code from the nameplate of an existing unit, and the quotation will confirm the exact configuration before order.
Documents and quotation
A manufacturer datasheet for the MICHELL Instruments XZR250 is attached to this page and covers the performance, electrical and dimensional data summarized above. To request availability and lead time, send an RFQ to Seven Star LLC with the part number MICHELL Instruments XZR250, the quantity, the probe or flange requirements and the delivery location in Oman or the GCC.
Other Models in the XZR Range
Seven Star LLC supplies models from the XZR range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| MICHELL Instruments XZR250 Zirconia Oxygen Analyzer 0.1-25% O2 | Gas Analyzer Systems | You are viewing this model |
| MICHELL Instruments XZR500 Combustion Control Oxygen Analyzer | Gas Analyzer Systems | View details |
Datasheets & Documents
- Datasheet MICHELL Instruments XZR250 Zirconia Oxygen Analyzer 0.1-25% O2 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the MICHELL Instruments XZR250 Zirconia Oxygen Analyzer
Answers from our engineering team on installation, compatibility and integration.
01What oxygen range does the XZR250 measure?
The XZR250 measures 0.1 to 25 percent oxygen, with output resolution of 0.01 percent O2, 0.01 mA or 0.01 V, and accuracy better than 0.25 percent O2.
02Does the XZR250 need instrument air or reference air?
No. Sample gas moves through the sensor chamber by the Pitot effect, and the micro ion pump sensor works without an air reference, so no instrument air is needed.
03What outputs does the XZR250 provide?
It has single or dual 4-20 mA analog outputs, RS485 MODBUS as standard, one system alarm relay and one user configurable process alarm relay.
04What is the maximum sample temperature for the XZR250?
The probe handles sample gas up to 700 C, and the datasheet states that short excursions to 750 C for 30 minutes will not damage it.
05What is the process connection of the XZR250?
It mounts on a 2 inch ANSI 150 lb flange profile with four 19.05 mm bolt holes on a 120.65 mm pitch circle diameter; the flange is not pressure retaining.