Michell XTC601-GP1 Binary Gas Analyzer, General Purpose

Description

Michell XTC601-GP1 thermal conductivity binary gas analyzer, general purpose

The Michell XTC601-GP1 is the general-purpose (safe-area) wall-mounted version of the XTC601 binary gas analyzer. It determines the percentage of one gas in a binary or pseudo-binary mixture, such as hydrogen purity in air, CO2 in methane or helium recovery, by comparing the thermal conductivity of the sample against a sealed reference chamber. Matched thermistors in a Wheatstone bridge, inside a temperature-controlled isothermal cell, give a stable signal. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

What XTC601-GP1 includes as standard

The code covers a backlit LCD with four capacitive buttons that work through the glass, an IP66 wall-mounted enclosure, a 316 stainless steel sample path, two 4 to 20 mA outputs, Modbus RTU over RS485, two concentration alarms, three M20 cable entries and 24 V DC power. The gas connection is 1/4 inch NPT female. Local screens show concentration with a status bar, a graph of the latest period, minimum and maximum values, readings from an external sensor and the alarm history. A light guide follows NAMUR 44.

XTC601-GP1 technical specifications

Part number XTC601-GP1
Gas connections 1/4 inch NPT female
Sample flow (general purpose) 100 to 500 ml/min
Ambient temperature +5 to +60 °C
Sample temperature constant +5 to +45/+55 °C
Sample cell temperature +50 or +60 °C
Warm-up / stabilisation under 25 minutes at 20 °C / 5 minutes
Measured gases air, argon, methane, CO2, hydrogen, helium or nitrogen (order codes add NMHC and CO)
Measurement range selectable from 0 to 1 percent up to 0 to 100 percent, or 50 to 100 up to 98 to 100 percent
Accuracy better than ±1 percent of range or ±0.05 percent H2 or He, whichever is greater
Response T90 under 50 seconds; under 20 seconds for H2 or He
Repeatability / linearity ±0.2 percent / ±1 percent of range
Zero and range stability ±0.5 percent of range per month each
Sample pressure fixed 0.75 to 1.5 bar A; maximum safe 1 barg
Outputs 2 x 4 to 20 mA, Modbus RTU RS485, 2 changeover alarm relays (250 V, 5 A)
Supply 24 V DC, 1.0 A maximum
Wetted materials 316L stainless steel, borosilicate glass, platinum, plus O-ring
Size and weight 234 x 234 x 172 mm; 9.7 kg; IP66 / NEMA 4

How XTC601-GP1 differs from XTC601-GP2 and XTC601-EX1

GP1 is the plain safe-area unit with 1/4 inch NPT female gas ports. The order-code sheet places GP2 alongside it with flame arrestors and 1/8 inch NPT female connections, and EX1 as the explosion-proof model, also with flame arrestors and 1/8 inch ports. The datasheet notes that hydrogen and methane targets require an explosion-proof analyzer or one equipped with flame arrestors, so GP1 is suitable only for gases such as helium, argon, CO2 or nitrogen in non-flammable duties or where a safe area and non-flammable sample are confirmed. The Ex versions also use a narrower sample flow of 270 to 330 ml/min.

Measuring principle in XTC601-GP1 explained

Every gas has its own thermal conductivity, and XTC601-GP1 exploits that difference to infer how much of the target gas is present in a known background. One thermistor sits in the flowing sample cell and the other in a sealed reference chamber; the pair forms a Wheatstone bridge in a temperature-controlled isothermal block, so ambient swings do not shift the zero. The datasheet states that this sensor largely eliminates the drift of comparable devices, which lengthens calibration intervals, and that it is non-depleting with no moving parts. The analyzer is calibrated in the background gas of the actual process, which is why the order string asks for both target and background gas. XTC601-GP1 should therefore be ordered with the real composition in mind.

Ordering the XTC601-GP1 configuration

After the base model the order string selects the cell O-ring (Viton or Ekraz), target gas, background gas, range letter, cell temperature (50 °C or 60 °C), SIL level (standard or IEC 61508 SIL 2 capable) and whether the unit is cleaned for oxygen service. Range options go from 0 to 1 percent (H2 or He only) through 0 to 100 percent, and also 50 to 100, 70 to 100, 80 to 100, 90 to 100 and 95 to 100 percent. Extras include factory recalibration, extended warranty of 24 or 36 months, a certificate of conformity, a BS EN 10204 3.1 material certificate and spare gland, plug and adaptor kits (XTC601-1/4 inch and XTC601-6MM adaptors for tube connection).

Typical uses of XTC601-GP1 in Oman and GCC industry

Air-separation product quality, helium recovery, fuel cell research, syngas and biomethane CO2 monitoring are listed uses. Industrial gas plants can use the unit to monitor purity of nitrogen, argon and CO2 headers. Because the sensor has no moving parts and does not deplete, it is unaffected by vibration and suits remote installations. Sample must be non-condensing with particles smaller than 3 µm, at constant temperature and pressure; calibrate at the same pressure as the sample.

Commissioning and maintenance of XTC601-GP1

Plan sample handling before ordering: a non-condensing sample with particles under 3 µm, constant temperature and a fixed pressure of 0.75 to 1.5 bar A. A filter, regulator and flowmeter ahead of the 1/4 inch NPT port are normal practice. Allow the warm-up of under 25 minutes, then 5 minutes for the signal to stabilise, before span checks. The mA output can be driven high or low in line with NAMUR when the cell temperature is unstable, so the control system can recognise the condition. The XTC application software offers remote access, graphs, parameter changes and remote calibration.

Documents and quotation

The XTC series datasheet and order-code sheet are provided as PDF references. For a quotation on XTC601-GP1, send an RFQ with the part number, the full option string (O-ring, target gas, background gas, range, cell temperature, SIL, oxygen cleaning), quantity and required documents.

Other Models in the Michell Xtc601 Range

Seven Star LLC supplies models from the Michell Xtc601 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Michell XTC601-EX1 Explosion-Proof Binary Gas AnalyzerGas Analyzer SystemsView details
Michell XTC601-GP1 Binary Gas Analyzer, General PurposeGas Analyzer SystemsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Michell XTC601-GP1 Binary Gas Analyzer, General Purpose Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the Michell XTC601-GP1 Binary Gas Analyzer, General

Answers from our engineering team on installation, compatibility and integration.

01What does XTC601-GP1 measure?
XTC601-GP1 measures one gas in a binary or pseudo-binary mixture using thermal conductivity, such as hydrogen in air or CO2 in methane.
02Is XTC601-GP1 explosion proof?
No. GP1 is the general-purpose model with 1/4 inch NPT connections. Explosion-proof or flame-arrestor versions are XTC601-EX1 and XTC601-GP2.
03What outputs does XTC601-GP1 provide?
It provides two 4 to 20 mA outputs, Modbus RTU over RS485 and two concentration alarm relays rated 250 V, 5 A, powered from 24 V DC.
04What sample conditions does XTC601-GP1 need?
The sample must be non-condensing with particles under 3 µm, at 0.75 to 1.5 bar A, flowing at 100 to 500 ml/min for general-purpose models.
05How fast does XTC601-GP1 respond?
T90 is under 50 seconds for most gas combinations and under 20 seconds for hydrogen or helium. Warm-up takes under 25 minutes.