Brand: Beamex
Beamex 8003192 PGHH Pressure Cylinder Service Kit
Description
Replacing a worn cylinder with Beamex 8003192
Beamex 8003192 is a factory-assembled pressure cylinder for the Beamex PGHH hydraulic calibration pump. The maker positions it for two situations: the pump still leaks after the cylinder seals were renewed from the 0500400 PGHH full service kit, or the technician simply prefers not to dismantle the cylinder. In both cases the whole cylinder assembly is exchanged in one piece. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
This is the most involved of the PGHH spare parts. The maker states that the kit contains internal parts that require opening the pump and that the work is only for skilled personnel.
What is inside 8003192
- One preassembled pressure cylinder.
- O-rings 10 x 2 mm, 14.3 x 2.4 mm and 15 x 2.5 mm for the pressure cylinder.
- Two check valves, each with spring and a 2.5 x 1 mm O-ring.
- A liquid suction hose with connector.
- Two 67 x 3 mm O-rings for the reservoir, which the maker recommends replacing at the same time.
The two check valves are what let the pump draw oil from the reservoir on the return stroke and push it toward the output on the pressure stroke. If either one is contaminated, the symptom is the one the manual describes: considerable pumping with no pressure rise.
Technical context from the PGHH manual
| Item | Detail |
|---|---|
| Part number | 8003192 |
| Description | PGHH pressure cylinder, preassembled |
| Pump pressure range | 0 to 700 bar / 0 to 10,000 psi |
| Hose pressure rating | 630 bar working, 2,000 bar bursting |
| Reservoir volume | 200 ml, not to be pressurized |
| Recommended fluids | RENOLIN MR 5 VG 22 mineral oil or distilled water |
| Test fluid at factory | WACKER AK 10 silicone fluid |
| Pump height x width x depth | 265 x 160 x 120 mm |
| Weight | 1.3 kg |
| Tightening torque | 25 Nm; drain screw maximum 15 Nm |
How 8003192 differs from the other PGHH kits
Compared with the 8003187 vent valve, which only changes the venting mechanism, 8003192 reaches into the pressure-generating path itself. Compared with the 8003194 reservoir kit it adds check valves and a suction hose, and compared with the 0500400 full service kit it supplies a complete cylinder rather than seals for rebuilding the old one. It also differs in size of repair: three cylinder O-ring sizes plus two reservoir O-rings are included, so far more of the pump is disturbed than with the stroke selector kit 8003199.
Typical reasons to order it
A pump that has been run on fluid with particles, or on mixed fluids, tends to fail at the cylinder seals and check valves first. The manual warns that residues from the device under test can damage the seals, O-rings and reservoir, and that cloudiness or dirt in the fluid is a sign to change it.
In Gulf conditions, where dust and process residue are common in service workshops, a spare 8003192 lets a metrology team return a field pump to service without waiting for factory repair. Teams that calibrate wellhead transmitters or hydraulic test benches at several hundred bar usually keep one per pump model.
Installation and leak check
Before opening the pump, depressurize, empty the reservoir and plan to use the maker’s video for 8003192. Replace the cylinder, renew the two reservoir O-rings, lightly grease O-rings with silicone lubricant and torque connections to 25 Nm. Prime the pump by squeezing the handles until fluid reaches the hose end.
Then follow the manual leak test: expel air by pumping to about 50 bar and venting two or three times, pressurize to the maximum of the module on top, wait five minutes, reset with the fine adjust, wait two minutes and confirm a fall of less than 5 bar from a 700 bar set point.
Care after the repair
Keep the pump upright during calibration so replacement air can pass through the pressure compensation screw. If this screw is blocked the acrylic reservoir may break. Clean the reservoir with a lint-free wet cloth only, never with chemicals, and change the oil at the first cloudiness.
Fit a reliable pressure indicator whenever the pump is used and never exceed the lowest rating in the chain, including the stated limit on any connected EXT module sticker.
Troubleshooting guide: when the pump will not build pressure
The manual gives a short checklist before any part is replaced. First check that connections between the pump, hose end and attached instruments are tight and repeat the closing of the vent valve. Second, make sure every unused pressure fitting is properly plugged. Only when pressure still does not rise is a leaking internal seal suspected, which leads to the leak test and, if needed, to a repair such as this cylinder.
The manual also tells the user not to keep pumping when the pump behaves abnormally: find the fault first. A strong counterforce on the handles with no reading change on the indicator is a typical warning that something is blocked, and the pump should be stopped at once. Ordering the correct spare part is easier when the exact symptom is written into the RFQ.
Safety limits to remember with the PGHH
The pressure built up inside the pump can be extremely high, so only experienced personnel should use it, with protective glasses. Only the maker’s hose marked Max. 630 bar should be used, with working pressure 630 bar and bursting pressure 2,000 bar at 20 degrees C reference, never a generic hose. Never exceed the maximum pressure of any connected device, and always depressurize before opening or connecting fittings.
Documents and quotation
The PGHH user manual serves as the datasheet for Beamex 8003192. For a quotation, send an RFQ to Seven Star LLC with part number 8003192, the quantity and the pump serial number. Lead time and stock are confirmed on request.
Other Models in the Pghh Spares Range
Seven Star LLC supplies models from the Pghh Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Beamex 8003187 PGHH Vent Valve Spare Assembly | Process, Pressure & Temperature Calibrators | View details |
| Beamex 8003192 PGHH Pressure Cylinder Service Kit | Process, Pressure & Temperature Calibrators | You are viewing this model |
| Beamex 8003194 PGHH Reservoir Replacement Kit | Process, Pressure & Temperature Calibrators | View details |
| Beamex 8003199 PGHH Stroke Selector Service Kit | Process, Pressure & Temperature Calibrators | View details |
Datasheets & Documents
- Datasheet Beamex 8003192 PGHH Pressure Cylinder Service Kit Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 8003192 PGHH Pressure Cylinder Service Kit
Answers from our engineering team on installation, compatibility and integration.
01When should I choose Beamex 8003192 instead of seals?
Choose it when the pump still leaks after fitting the seals from the 0500400 full service kit, or when you prefer not to dismantle the cylinder.
02Are reservoir O-rings included?
Yes. Two 67 x 3 mm O-rings for the reservoir are in the kit, and the maker recommends replacing them when the cylinder is changed.
03Who should fit 8003192?
Skilled personnel only, because the work requires opening the pump to reach internal parts.
04What check valve parts come with it?
Two check valves with springs and 2.5 x 1 mm O-rings, together with a liquid suction hose and connector.
05Which pump does it belong to?
It fits the Beamex PGHH hydraulic pump covering 0 to 700 bar / 0 to 10,000 psi.