Brand: Pepperl+Fuchs
Pepperl+Fuchs KFD2-UT2-Ex2-1 Temperature Converter
Description
KFD2-UT2-Ex2-1: voltage-output temperature barrier
Some PLC and DCS input cards read 1 to 5 V instead of 4 to 20 mA, and for those systems the Pepperl+Fuchs KFD2-UT2-Ex2-1 replaces the current-output UT2-Ex2. Its two intrinsically safe input channels accept thermocouples, RTDs, potentiometers and millivolt sources from the hazardous area, and each channel produces a voltage of 0 to 5 V or 1 to 5 V with an output resistance of 5 ohm or less and a load of at least 10 kilohm.
Everything else about the module is shared with the current version: PACTware configuration, signal-splitter operation, line-fault and sensor-burnout detection, and the 20 mm wide B2 housing.
What the voltage outputs mean in practice
- Terminals 7- and 8+ carry output I; terminals 10- and 11+ carry output II
- Fault signal downscale 0 V or 0.5 V, upscale 5.375 V
- Accuracy of the 1 to 5 V output: 4 mV from 0 to 103.1 percent of span; of the 0 to 5 V output: 4 mV from 0.3 to 102.5 percent of span
- Supply 20 to 30 V DC on terminals 14+ and 15- or from the Power Rail; power dissipation 0.8 W
Datasheet values for KFD2-UT2-Ex2-1
| Parameter | Value |
|---|---|
| Channels | 2 isolated, signal-splitter capable |
| Output signal | 0 to 5 V or 1 to 5 V |
| Output resistance / load | 5 ohm or less / 10 kilohm or more |
| Supply | 20 to 30 V DC, 0.8 W maximum |
| Pt100 deviation after calibration | 0.06 percent of reading in K plus 0.1 K (4-wire) |
| Thermocouple deviation | 0.05 percent of reading plus 1 K (1.2 K for R and S), including 0.8 K CJC error |
| Millivolt deviation | 50 microvolts |
| Potentiometer deviation | 0.05 percent of full scale, excluding lead resistance |
| Supply influence | less than 0.01 percent of span |
| Safe-side entity values | Uo 9 V, Io 22 mA, Po 50 mW |
| ATEX | CESI 04 ATEX 143; TUV 02 ATEX 1797 X |
| Zone 2 marking | Ex nA II T4 for the non-intrinsically safe side |
| Insulation | safe electrical isolation, peak 375 V (IEC/EN 60079-11) |
| Mechanical | 20 x 119 x 115 mm, about 130 g, screw terminals |
Using one sensor for two receivers
In splitter mode a single thermocouple on channel one feeds both voltage outputs. A typical arrangement sends one output to the DCS and the other to a stand-alone recorder or a protective system. Because the outputs are isolated from each other, a ground fault on one receiver does not disturb the other.
How KFD2-UT2-Ex2-1 differs from KFD2-UT2-Ex2
The current-output KFD2-UT2-Ex2 dissipates 1.53 W and offers 0 to 20 mA, 4 to 20 mA and sink or source options; KFD2-UT2-Ex2-1 produces voltage, draws only 0.8 W and requires a high-impedance receiver. Fault levels differ too (5.375 V upscale rather than 21.5 mA). The single-channel KFD2-UT2-1-1 is a non-hazardous-area conditioner with the same voltage output.
Cabinet and wiring
Voltage signals are more sensitive to noise on long cable runs than current loops, so keep output wiring short and screened. Place the module near the receiving card where possible. The lower 0.8 W dissipation helps in crowded Gulf cabinets.
Commissioning steps
Choose the voltage range in PACTware, apply a calibrator to each input and verify 1 V and 5 V endpoints with a multimeter of sufficient resolution. Check the burnout direction by removing the sensor.
Support information
Keep the exported PACTware project with the loop folder, together with the receiver range and the burnout direction chosen. For replacement, upload the file to the new module, confirm the output at both endpoints and re-test the alarm thresholds in the control system.
Reading the accuracy figures correctly
The deviation quoted for the Pt100 input, 0.06 percent of the measured value in kelvin plus 0.1 K on a four-wire connection, is the figure after calibration at the reference temperature. At 200 degrees C (473 K) the proportional part is about 0.28 K, so the combined error stays near 0.4 K. Thermocouple inputs include a 0.8 K cold-junction contribution, which is why a type K reading at 400 degrees C carries roughly 1.0 K plus 0.2 K of proportional error. The voltage output itself adds 4 mV from 0 to 103.1 percent of span on the 1 to 5 V range. Budget these together with the receiver card accuracy and the resolution of the analogue input channel when writing the loop uncertainty calculation, and state the temperature span used so that reviewers can reproduce the figures from the datasheet.
Questions buyers ask about KFD2-UT2-Ex2-1
What output voltage does KFD2-UT2-Ex2-1 give? Each channel provides 0 to 5 V or 1 to 5 V with an output resistance of 5 ohm or less into a load of at least 10 kilohm.
What are the fault levels of KFD2-UT2-Ex2-1? The fault signal is downscale 0 V or 0.5 V and upscale 5.375 V.
How much power does KFD2-UT2-Ex2-1 use? Supply is 20 to 30 V DC with a power dissipation and consumption of 0.8 W at most.
Which terminals carry the outputs of KFD2-UT2-Ex2-1? Output I is on terminals 7- and 8+, and output II on terminals 10- and 11+.
Is KFD2-UT2-Ex2-1 an intrinsically safe barrier? Yes. Its inputs on terminals 1 to 6 are Ex ia with Uo 9 V, Io 22 mA and Po 50 mW under certificate CESI 04 ATEX 143.
Documents and quotation
The manufacturer datasheet for KFD2-UT2-Ex2-1 accompanies this listing as a PDF so your engineers can verify terminals, ratings and approvals before purchase. Specify the receiver card input range with your enquiry. To request a quotation, send the RFQ with the exact part number KFD2-UT2-Ex2-1, the quantity, the delivery location in Oman or the GCC and any project reference. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Documentation and Compliance
Industrial buyers often need more than the hardware. When you order the Pepperl+Fuchs KFD2-UT2-Ex2-1, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Pepperl+Fuchs isolator & barrier items can be checked against the bill of materials quickly.
Other Models in the Ut2 Temp Range
Seven Star LLC supplies models from the Ut2 Temp range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pepperl+Fuchs KFD2-UT2-1-1 Temperature Signal Conditioner | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-UT2-Ex2-1 Temperature Converter | Isolator & Barrier | You are viewing this model |
Datasheets & Documents
- Datasheet Pepperl+Fuchs KFD2-UT2-Ex2-1 Temperature Converter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-UT2-Ex2-1 Temperature Converter
Answers from our engineering team on installation, compatibility and integration.
01What output voltage does KFD2-UT2-Ex2-1 give?
Each channel provides 0 to 5 V or 1 to 5 V with an output resistance of 5 ohm or less into a load of at least 10 kilohm.
02What are the fault levels of KFD2-UT2-Ex2-1?
The fault signal is downscale 0 V or 0.5 V and upscale 5.375 V.
03How much power does KFD2-UT2-Ex2-1 use?
Supply is 20 to 30 V DC with a power dissipation and consumption of 0.8 W at most.
04Which terminals carry the outputs of KFD2-UT2-Ex2-1?
Output I is on terminals 7- and 8+, and output II on terminals 10- and 11+.
05Is KFD2-UT2-Ex2-1 an intrinsically safe barrier?
Yes. Its inputs on terminals 1 to 6 are Ex ia with Uo 9 V, Io 22 mA and Po 50 mW under certificate CESI 04 ATEX 143.