Pepperl+Fuchs KFD2-DU-Ex1.D Timer Relay Switch Amplifier
Description
KFD2-DU-Ex1.D timer relay barrier from Pepperl+Fuchs
The Pepperl+Fuchs KFD2-DU-Ex1.D is a hazardous-area switch amplifier that doubles as a programmable timer. A NAMUR proximity sensor or a mechanical contact in the field feeds its intrinsically safe input, and the module reshapes the resulting signal before it reaches the relay and the transistor output in the safe area. Instead of adding a separate time-delay relay to the cabinet, the engineer sets the function on the keypad.
The available behaviours are on-delay, off-delay, one-shot and pulse lengthening, with durations adjustable from 10 ms up to 60 minutes. A pulse divider can additionally step input pulses down at ratios from 1:1 to 9999:1, which turns a fast counting signal into a slow one that a PLC input can follow.
What sets this timer module apart
- Two outputs: a relay on terminals 10, 11, 12 and an isolated electronic output on terminals 19+ and 20- (40 V, 50 mA)
- Reset input II on terminals 13+ and 14-, active above 4 mA and passive below 1.5 mA, pulse length at least 10 ms
- Input frequency 0 to 80 Hz, pulse divider range to 1 kHz
- Switching point 1.2 to 2.1 mA with a hysteresis of about 0.2 mA
- 24 V DC from terminals 23+ and 24- or from a Power Rail, with line-fault reporting on the collective error output
KFD2-DU-Ex1.D technical data
| Parameter | Value |
|---|---|
| Supply | 20 to 30 V DC, about 100 mA, 1.8 W |
| Input I | NAMUR, open-circuit 8.2 V, short-circuit 10 mA |
| Minimum pulse duration | 75 microseconds / 1 ms depending on mode, see manual |
| Timing resolution | better than 0.1 percent of set value, minimum 10 ms |
| Timing accuracy | 2 ms |
| Temperature influence | 0.003 percent per K (50 ppm) |
| Line-fault thresholds | breakage 0.15 mA or less; short circuit above 6.5 mA |
| Relay contact | 253 V AC / 2 A / cos phi 0.7 or better; 40 V DC / 2 A |
| Electronic output | 1-signal about supply minus 2.5 V at 50 mA, short-circuit proof; off-state current 10 microamps or less |
| Output II switching times | 3 ms after rising and 2 ms after falling input edge |
| Safe-side values | Uo 10.1 V, Io 13.5 mA, Po 34 mW |
| Certificates | TUV 99 ATEX 1408; TUV 02 ATEX 1885 X; IECEx TUN 03.0000; FM 16-538FM-12; UL E223772 |
| Housing | type C2, 40 x 119 x 115 mm, about 300 g, IP20 |
Timer applications in process plants
Valve limit switches on shutdown valves often chatter during stroke; a short off-delay masks the contact bounce so that the logic sees a clean state. A burner flame-proving sensor can use an on-delay, so a momentary flicker is ignored. A one-shot stretches the pulse of a gas-detector relay long enough for a slow scan cycle to capture it. On packaging and filling lines the divider turns a flow-meter pulse stream into a batch count. In every case the hazardous-area contact is read through an Ex ia circuit.
How KFD2-DU-Ex1.D differs from other DU and SH variants
- KFD2-DU-Ex1.D runs on 24 V DC with a Power Rail option; KFA6-DU-Ex1.D is supplied from 230 V AC and KFA5-DU-Ex1.D from 115 V AC.
- Its reset input draws a 12 V / 3.5 mA source on the AC versions but 18 V / 5 mA here.
- Compared with the simple KFD2-SH-Ex1.T.OP switch amplifier, it adds the time functions and a second electronic output, but it has a lower frequency ceiling (80 Hz).
Programming the timer
The keypad on the front allows selection of function, time value, divider ratio and the normal or inverted relay action. After programming, simulate the contact and watch the relay and the electronic output. The reset input can terminate a running delay: close a dry contact on terminals 13 and 14 for at least 10 ms. Record each parameter in the loop sheet; field replacement then becomes a repeat of the same steps.
Cabinet layout
Place the module on a rail where the blue intrinsically safe terminals face away from mains wiring. If several are on a Power Rail, remember the 1.8 W dissipation per unit when calculating cabinet heat load, and feed the rail through a KFD2-EB2 power feed module. A Universal Power Rail UPR-03 with end caps and cover distributes the 24 V DC to neighbouring modules, so no individual supply wiring is needed. Leave the front keypad window accessible, because timer values are changed there during commissioning and again after process modifications, and label each module with the function it performs.
Maintenance routine
Verify the delay with a stopwatch or a logic analyser at each plant inspection and exercise the relay. Relay endurance is 5 x 10 to the power 7 operations. Keep spare terminals available because screw terminals loosen after thermal cycling.
Selecting this part number
Choose KFD2-DU-Ex1.D when the control cabinet already has 24 V DC and when relay switching up to 253 V AC or 40 V DC at 2 A is needed, together with an extra electronic output for a PLC input. Pick another voltage variant only when no DC bus exists. The order of terminals 10 to 12, 13 and 14, and 19 and 20 remains the same in all voltage versions, so wiring changes are minor.
Questions buyers ask about KFD2-DU-Ex1.D
What time range can KFD2-DU-Ex1.D generate? The output timer functions are adjustable from 10 ms to 60 minutes, and the pulse divider supports ratios from 1:1 to 9999:1.
Which outputs does KFD2-DU-Ex1.D provide? It has a relay output on terminals 10, 11 and 12 and an isolated electronic output on terminals 19+ and 20- rated 40 V and 50 mA.
What does the reset input of KFD2-DU-Ex1.D do? Input II on terminals 13+ and 14- terminates a running time function when a dry contact is closed for at least 10 ms.
What is the maximum input frequency of KFD2-DU-Ex1.D? The input frequency is 0 to 80 Hz, and the pulse divider function covers up to 1 kHz.
How is KFD2-DU-Ex1.D powered? It uses 20 to 30 V DC at about 100 mA, connected to terminals 23+ and 24- or taken from a Power Rail.
Documents and quotation
The manufacturer datasheet for KFD2-DU-Ex1.D accompanies this listing as a PDF so your engineers can verify terminals, ratings and approvals before purchase. Describe the intended time function in your enquiry if you would like the team to check the range. To request a quotation, send the RFQ with the exact part number KFD2-DU-Ex1.D, the quantity, the delivery location in Oman or the GCC and any project reference. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Other Models in the Du Timer Range
Seven Star LLC supplies models from the Du Timer range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pepperl+Fuchs KFA5-DU-Ex1.D Timer Relay 115 V AC | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-DU-Ex1.D Timer Relay Switch Amplifier | Isolator & Barrier | You are viewing this model |
Datasheets & Documents
- Datasheet Pepperl+Fuchs KFD2-DU-Ex1.D Timer Relay Switch Amplifier Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-DU-Ex1.D Timer Relay Switch
Answers from our engineering team on installation, compatibility and integration.
01What time range can KFD2-DU-Ex1.D generate?
The output timer functions are adjustable from 10 ms to 60 minutes, and the pulse divider supports ratios from 1:1 to 9999:1.
02Which outputs does KFD2-DU-Ex1.D provide?
It has a relay output on terminals 10, 11 and 12 and an isolated electronic output on terminals 19+ and 20- rated 40 V and 50 mA.
03What does the reset input of KFD2-DU-Ex1.D do?
Input II on terminals 13+ and 14- terminates a running time function when a dry contact is closed for at least 10 ms.
04What is the maximum input frequency of KFD2-DU-Ex1.D?
The input frequency is 0 to 80 Hz, and the pulse divider function covers up to 1 kHz.
05How is KFD2-DU-Ex1.D powered?
It uses 20 to 30 V DC at about 100 mA, connected to terminals 23+ and 24- or taken from a Power Rail.