Brand: Beamex
Beamex 9010050 PGC Calibration Pump Complete Kit 35 bar
Description
Beamex 9010050 PGC pump kit in a hard case
Beamex 9010050 is the complete-kit version of the PGC hand pump, rated from -0.95 to 35 bar (-13.7 to 510 psi) with air as the medium. Where the pump-only variant arrives as a bare unit and a manual, the 9010050 is packed so that a technician can walk to a transmitter, connect and calibrate without hunting for hoses and adapters. Everything sits in a protective hard case.
The pump itself is compact: 220 mm high, 120 mm wide, 65 mm deep, and only 820 g. A single hand squeezes the two handles, a selector chooses pressure or vacuum, and a fine adjust trims the final millibars. That small size is why the PGC is usually the field pump in a Beamex-based calibration setup in the Gulf.
Choosing the kit also removes a common mistake: the T-hose and the fitting set shipped inside 9010050 are matched to the pump port, so the 40 bar hose rating and the Bx G1/8 inch thread are consistent from the pump to the calibrator and to the instrument.
What is inside the 9010050 box
| Item | Content |
|---|---|
| Pump | PGC calibration pump, -0.95 to 35 bar |
| Hose set | 40 bar (600 psi) pressure T-hose set, 1.5 m, with 1/4 inch and 1/8 inch NPT fittings and seals (code 8009550) |
| Fitting set | Bx G1/8 inch male to G1/8 inch male and G1/4 inch B female, for linking 40 bar hoses to internal and external pressure modules (code 8003100) |
| Documentation | User manual |
| Case | Hard case for PGC (code 8003312) |
The T-hose is built for 40 bar working pressure and 80 bar bursting pressure, with a 2 mm bore, 5 mm outer diameter, a 20 mm minimum bending radius (30 mm below -20 degrees C) and Bx G1/8 inch female connectors on every end. It operates from -40 to 100 degrees C.
PGC pump data carried in 9010050
| Parameter | Value |
|---|---|
| Pressure range | -0.95 to 35 bar (-13.7 to 510 psi) |
| Side port | G1/8 inch female, pre-fitted with Bx G1/8 inch male for Beamex 40 bar hoses |
| Top port | Plugged G3/8 inch B female |
| Medium | Air |
| Weight | 820 g (1.81 lb) |
| Dimensions (H x W x D) | 220 x 120 x 65 mm |
| Materials | Aluminum, brass, ABS, NBR |
| Operating temperature | 0 to 50 degrees C |
| Storage temperature | -20 to 60 degrees C |
Using the 9010050 in the field
Plug the T-hose into the side port, run one branch to the device under test and the other to the reference, either an MC6-family calibrator with an internal module or an EXT module. Flip the selector with a small screwdriver to the pressure position while the circuit is vented, close the release valve and squeeze. The manual notes that pumping alone gets you to roughly 20 to 25 bar; anything higher comes from winding the fine adjust, and the final reach depends on the volume of the circuit. After a change, expect the reading to settle for 30 to 60 seconds because of thermodynamic effects and hose seals. Handle spread is adjustable: loosen the lower nut, turn the upper one for spring tension, then lock the lower nut again.
9010050 versus the pump-only 9010060 and other PGC choices
The only difference between 9010050 and 9010060 is the delivered package: 9010060 contains the pump and manual, while the 9010050 adds the T-hose, the fitting set and the hard case. Pump specifications are identical. Choose the kit when you have no 40 bar hose and no Bx fittings yet, or when a crew needs a self-contained travel set; choose pump-only when you already stock hoses and a case for the PGC. Against the PGPH (9010180) the PGC reaches 35 bar instead of 140 bar but is one-ninth of the weight.
Care of the 9010050 and its hose
Seals and O-rings wear with use; the manual shows lock ring, 1/8 inch PVC gasket and brass washer, four M3 x 6 cylinder screws, a square-ring piston seal, four G1/8 inch bonded seals, three 3.17 x 1.78 O-rings and one 8 x 2.5 O-ring as the replaceable set. Do not seal any part with PTFE tape, avoid using the plugged top port because the aluminum body thread can be damaged, and never switch the selector under pressure. Beamex advises replacing pressure hoses every five years even without visible damage. A quick leak check: build 25 bar, raise to 28 bar with the fine adjust and hold one minute; the drop must stay within 0.09 bar. For vacuum, pull -0.85 bar and the drop must stay within 0.02 bar.
Applications for the 9010050 across Oman industry
The kit suits instrument technicians working on pressure transmitters, local gauges and pressure switches in oil and gas plants, power stations and water treatment facilities, where ranges rarely exceed 35 bar. Because pressure and vacuum come from the same device, one pump also covers compound-range transmitters and vacuum switches. Operators who carry a hard-cased calibrator out to remote wellsites will appreciate that the case protects the pump during transport. In summer ambient conditions the stated operating window of 0 to 50 degrees C is worth remembering when the case sits in a vehicle, and the storage limit is 60 degrees C. Water and wastewater crews can pair the pump with a dirt and moisture trap when process instruments may contain condensate, because the manual warns that moisture and dirt can corrode the interior of the pump.
Documents and quotation
The PGC user manual lists the delivery contents, specifications, leak test limits and the seal diagram. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. When you ask for a quotation, give Beamex 9010050 and the quantity, and name the 9010060 pump-only alternative if you want us to quote both.
Delivery to Sites in Oman and the GCC
Delivery of the Beamex 9010050 is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive process, pressure & temperature calibrators equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.
Other Models in the Beamex Pg Pump Range
Seven Star LLC supplies models from the Beamex Pg Pump range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Beamex 9010180 PGPH Pneumatic Calibration Pump 140 bar | Process, Pressure & Temperature Calibrators | View details |
| Beamex 9010050 PGC Calibration Pump Complete Kit 35 bar | Process, Pressure & Temperature Calibrators | You are viewing this model |
Datasheets & Documents
- Datasheet Beamex 9010050 PGC Calibration Pump Complete Kit 35 bar Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 9010050 PGC Calibration Pump Complete Kit 35
Answers from our engineering team on installation, compatibility and integration.
01What does the Beamex 9010050 include besides the pump?
It adds a 1.5 m 40 bar T-hose set with 1/4 inch and 1/8 inch NPT fittings, a Bx G1/8 inch fitting set, the user manual and a hard case.
02What pressure can the 9010050 generate by pumping alone?
The manual states roughly 20 to 25 bar from pumping; higher pressure up to the 35 bar limit comes from the fine adjust, depending on circuit volume.
03Which hose may be used with the PGC pump?
Only Beamex hoses marked Max. 40 bar; other hoses might not withstand the pressure the pump can produce.
04How is a leak test done on the 9010050?
Pump to 25 bar, raise to 28 bar and hold one minute with a drop of no more than 0.09 bar; for vacuum, -0.85 bar with no more than 0.02 bar change.
05Is the 9010050 the same pump as the 9010060?
Yes, the pump data matches; the 9010060 is sold without the hose set, fitting set and hard case.