Brand:

Beamex 9405250 RPRT-660-230A Reference Temperature Sensor

Description

Beamex 9405250 RPRT-660-230A reference temperature sensor

Beamex 9405250 is the RPRT-660-230A, a platinum resistance reference thermometer for the most demanding temperature calibrations, calibrated from 0 to 660 degrees C (32 to 1220 degrees F). The sensor is bent at 90 degrees, with 230 mm of sheath before the angle, and ends in a 1.8 m Teflon cable with a smart 6-pin LEMO connector. Beamex quotes stability of up to plus or minus 0.007 degrees C for the RPRT range.

An angled probe is the choice when the dry block or bath leaves limited headroom above the insert: the cable leaves sideways, so the sensor goes into a well without lifting the cable high above the instrument.

Specification of the 9405250

Parameter Value
Calibrated range 0 to 660 degrees C
Measurement capability -200 to 660 degrees C (accuracy only for the calibrated range)
Nominal resistance at 0.010 degrees C 100 ohm plus or minus 0.5 ohm
Temperature coefficient 0.003925 ohm/ohm/degree C
Sheath 6.35 mm plus or minus 0.08 mm diameter, Inconel 600
Shape and length 230 mm before the 90 degree angle
Maximum immersion depth (angled) 210 mm
Minimum immersion depth 100 mm for an error under 5 mK
Short-term repeatability plus or minus 0.007 degrees C at 0.010 degrees C; plus or minus 0.013 degrees C at maximum temperature
Drift after 100 h at maximum plus or minus 0.007 degrees C at 0.010 degrees C; plus or minus 0.013 degrees C at maximum
Hysteresis plus or minus 0.010 degrees C maximum
Sensing element 30 mm plus or minus 5 mm long, 3 mm plus or minus 1 mm from the tip
Response time 12 seconds typical
Self heating 50 mW per degree C in a 0 degrees C bath

Cable, junction and connector

The lead wire is Teflon-insulated 24 AWG stranded silver-plated copper, 1.8 m long, rated -50 to 250 degrees C. A transition junction measuring 71 x 12.5 mm joins the sheath and the cable; it must stay between -50 and 200 degrees C, because hotter temperatures cause irreparable damage, and for best performance it should not become too hot to touch. Minimum insulation resistance is 500 megohm at 23 degrees C and 10 megohm at 670 degrees C. The 6-pin LEMO connector is compatible with Beamex MC6 family calibrators and Beamex dry blocks, and an adapter cable lets the sensor work with devices that have four banana contacts.

Calibration data delivered with 9405250

An accredited calibration certificate is always included, with sensor-specific ITS-90 and Callendar-Van Dusen correction coefficients. Calibration is carried out at 0, 156, 232, 420 and 660 degrees C, and additional points down to -80 degrees C are available on request. The coefficients are also stored in the memory of the sensor so that a connected Beamex calibrator can read them. The sensor must always be used with these coefficients to meet its accuracy specification. The probe is delivered in a hard case.

How 9405250 differs from other RPRT variants

The RPRT family has four models. The 9405250 (RPRT-660-230A) shares its 0 to 660 degree range with the straight RPRT-660-300 (9405200), but is angled and has 230 mm of sheath before the bend, giving 210 mm maximum immersion where the straight probe allows 305 mm. The two 420 degree models, RPRT-420-300 and RPRT-420-230A (9405050), have a lower calibrated range of -45 to 420 degrees C and are the choice for sub-zero work. Choose the 660 degree angled version when you need high-temperature reference measurements in a dry block with tight overhead space.

Using the 9405250 with dry blocks and calibrators

Plug the LEMO connector into the reference input of an MC6-family calibrator or a Beamex dry block. The immersion depth must be sufficient: the minimum for an error below 5 mK is 100 mm, so insert the sensor well past that. Keep the transition junction out of heat and avoid mechanical shocks, since reference-grade platinum sensors are sensitive. Let the block stabilize before reading, and use the correction coefficients so that the readout follows ITS-90. With the 9405250 the angled shape means the hot part is the first 210 mm at most; the handle, cable and junction stay outside the block, and the sensing element sits about 3 mm from the tip, so a short insert can still bring the element into the isothermal zone as long as the 100 mm minimum depth is respected. Self heating of 50 mW per degree C in a 0 degree bath is small for a 100 ohm element, but it is one more reason to let the reading settle.

Care and handling of the 9405250

Store the probe in its hard case, never bend the sheath beyond the angle supplied and avoid exposing the cable and junction to the full block temperature. The sensor can measure down to -200 degrees C, but accuracy is specified only over 0 to 660 degrees C, so do not rely on certificate uncertainty outside that range. Recalibration intervals should follow your own quality system. A drop or a hard knock can shift the resistance of a reference sensor, so many laboratories check the 9405250 at the ice point after transport. Store the connector and the cable without tight bends, and keep the hard case closed when the sensor is not in use.

Use in Oman and GCC laboratories

Accredited and in-house calibration laboratories in Oman and the Gulf use reference thermometers like the 9405250 to calibrate RTDs and thermocouples used in refineries, power generation and food processing. The 660 degree range covers typical steam, flue and furnace instrument checks.

Documents and quotation

The RPRT brochure provides the model table and full specifications. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send your RFQ with Beamex 9405250, the quantity and whether you want additional calibration points.

Installation and Commissioning Planning

Planning ahead shortens downtime when a Beamex 9405250 goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Beamex equipment can be planned around it.

Datasheets & Documents
  • PDF Datasheet Beamex 9405250 RPRT-660-230A Reference Temperature Sensor Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 9405250 RPRT-660-230A Reference Temperature

Answers from our engineering team on installation, compatibility and integration.

01What temperature range does Beamex 9405250 cover?
The calibrated range is 0 to 660 degrees C, while the measurement capability extends to -200 degrees C without an accuracy specification below 0.
02Is 9405250 straight or angled?
It is the angled version, with 230 mm of sheath before a 90 degree bend and 210 mm maximum immersion depth.
03Which connector does the 9405250 use?
A smart 6-pin LEMO connector at the end of a 1.8 m Teflon cable, compatible with Beamex MC6 family calibrators and dry blocks.
04Does 9405250 include calibration coefficients?
Yes. An accredited certificate with ITS-90 and CvD coefficients is included, and the coefficients are stored in the sensor memory.
05How does 9405250 differ from 9405200?
Both cover 0 to 660 degrees C, but 9405200 is straight with 305 mm length while 9405250 is bent 90 degrees with 230 mm before the angle.