Condumax II CD2-SYS-M Analyzer with Sampling System
Description
Michell CD2-SYS-M overview: Condumax II hydrocarbon dew-point analyzer supplied with a sampling system, metric tube version
Michell CD2-SYS-M is the order code for the Condumax II hydrocarbon dew-point analyzer supplied on a sample system with 6 mm tube and twin ferrule compression fittings. It is the metric counterpart of CD2-SYS-I, with pressure, flow-control and filter options, 316L stainless steel wetted parts and Viton soft parts.
This page repeats the facts published by the manufacturer for Michell CD2-SYS-M so that engineers, maintenance planners and buyers can confirm the code before sending an enquiry. The photograph shows the Michell product line that the CD2-SYS-M code belongs to, taken from the manufacturer product page.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list CD2-SYS-M so that procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of CD2-SYS-M
- Sample system built around the Condumax II base analyzer
- 6 mm tube with twin ferrule compression fittings
- Gas-wetted parts in 316L stainless steel with Viton soft parts
- Gas and cable entries located in the base of the enclosure
- Bypass flow rate of 0.4 m3 per hour (6.6 L/min) nominal
- Analyzer ±0.5 °C hydrocarbon dew-point accuracy
CD2-SYS-M technical specifications
| Parameter | Value |
|---|---|
| Order code | CD2-SYS-M |
| Tube size | 6 mm, twin ferrule compression fittings |
| Wetted materials | 316L stainless steel, Viton soft parts |
| Bypass flow rate | 0.4 m3/h (6.6 L/min) nominal |
| Analyzer options | Hydrocarbon dew point; hydrocarbon plus water dew point (IGT or ISO); ATEX/IECEx or North American certified |
| Indoor system | 316 SS mounting plate |
| Outdoor system | 316 SS enclosure with heating options |
| Analyzer accuracy | ±0.5 °C hydrocarbon dew point |
| Analyzer operating pressure | 15 to 100 barg (218 to 1450 psig) |
| Analyzer hazardous-area marking | ATEX/UKCA II 2 G Ex db IIB+H2 T3 Gb, Tamb -40 to +60 °C |
Values above are taken from the manufacturer datasheet and order-code sheet listed on this page. The manufacturer states that specifications can change as part of continuous development, so confirm the current revision when the CD2-SYS-M is part of a tender or a certified installation.
Typical applications of CD2-SYS-M in Oman and the GCC
Typical duties are natural gas processing, turbo-expander protection, custody-transfer gas quality and pipeline monitoring. Metric tubing is common on European-built skids found in Gulf gas plants, which is the reason this variant is requested.
- Oil and gas: gas processing plants, wellsites, export pipelines and metering stations
- Utilities and power: turbine fuel gas, instrument air and compressed air systems
- Water and desalination: process air, gas generation and laboratory support
- Manufacturing and laboratories: calibration, electronics, pharmaceutical and industrial gas production
Dew point is the temperature at which water vapour in a gas begins to condense at a given pressure, so a lower dew point means drier gas. Pressure dew point is the value at line pressure and is the figure that matters for compressed air and process gas, while atmospheric dew point refers to the same gas expanded to ambient pressure and reads much lower. Moisture can also be expressed in ppmV, a pressure-corrected volume fraction, so always confirm the unit and the reference pressure on a specification.
Good sample handling decides the quality of any moisture or dew-point reading. Use stainless steel tubing, keep lines short, avoid dead legs and filter out particles and liquids before the sensor. Plastic or rubber tubing absorbs and releases water vapour and slows the response, particularly at low dew points, and ambient moisture can enter through poorly made fittings, so check for leaks after commissioning.
Selection and compatibility notes for CD2-SYS-M
Pick CD2-SYS-M where the existing skid uses 6 mm tubing. The analyzer type, hazardous-area certification, indoor or outdoor enclosure and heater voltage are chosen in the configuration letters of the order sheet, so quote them together with the code.
Many Michell codes are built from a parent code followed by option letters. When you ask for a quotation for CD2-SYS-M, copy the complete code from the instrument label or from your purchase specification, including every letter after the parent code, and state the serial number if the unit replaces an installed one.
Before ordering, collect the data that avoids mistakes: the complete code and option letters, the serial number and year of any installed unit, the supply voltage, the hazardous-area certificate required by the site, the process pressure and temperature, the gas composition and the connection type. For spares from older installations, a photograph of the nameplate helps confirm the match, and it is useful to say whether the item replaces a failed device or is for a new installation.
Ask for the calibration certificate type your quality system needs, such as a traceable factory certificate or an accredited laboratory certificate where the manufacturer offers it, and keep it with the asset record so the next calibration date is visible during audits.
Installation and commissioning of CD2-SYS-M
Fit the system near the tapping, connect 6 mm tubes to the compression fittings, bring cables in through the base and set the pressure and flow as described in the manual.
Always read the current manufacturer manual before commissioning, check the hazardous-area certificate where one applies, verify the supply and signal wiring, and record the as-found settings so that the next service visit has a reference.
Gulf installations add heat, dust and humidity. Instruments mounted outdoors need shade or a suitable enclosure, cable glands that match the enclosure rating and sample lines that avoid condensation on cold desert nights. Compare the ambient temperature range in the table with the highest site temperature before choosing a mounting position.
Maintenance and calibration of CD2-SYS-M
Replace filter elements and clean the analyzer mirror according to the manual and the plant routine for hazardous-area equipment.
Moisture and dew-point measurements drift only slowly when the sample is clean, so most problems seen on installations of this kind come from contaminated sample lines, leaking fittings, wrong flow or damaged cables rather than from the instrument itself. A planned calibration interval agreed with your quality system keeps the measurement traceable.
Related products and ordering notes for CD2-SYS-M
The same manufacturer family includes sensors, transmitters, online hygrometers, chilled-mirror reference instruments, hydrocarbon dew-point analyzers, sampling systems and calibration equipment. Other Michell codes already listed on this site, such as the Easidew transmitters, the Promet EExd analyzer and the Condumax II, can be quoted together in a single RFQ.
CD2-SYS-M FAQ summary
Typical questions concern what the code means, which options apply and what to send with an enquiry. In short, it is a Condumax II hydrocarbon dew-point analyzer supplied with a sampling system, metric tube version, and the figures in the table above come from the manufacturer documents. Questions that are not answered here can be sent with the RFQ.
Documents and quotation
The manufacturer datasheet for CD2-SYS-M is attached to this page where available. To request a quotation, send an RFQ with the part number CD2-SYS-M, the quantity and your delivery location in Oman or the GCC, and we will reply with availability and lead time.
Datasheets & Documents
- Datasheet Condumax II CD2-SYS-M Analyzer with Sampling System Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Condumax II CD2-SYS-M Analyzer with Sampling System
Answers from our engineering team on installation, compatibility and integration.
01What is CD2-SYS-M?
CD2-SYS-M is a Condumax II hydrocarbon dew-point analyzer supplied with a sampling system, metric tube version, as described in the manufacturer datasheet and order-code sheet.
02What tube does CD2-SYS-M use?
It uses 6 mm tube with twin ferrule compression fittings; CD2-SYS-I is the 1/4 inch version.
03Which materials touch the gas in CD2-SYS-M?
The order sheet states 316L stainless steel gas-wetted parts with Viton soft parts.
04Can Seven Star LLC supply CD2-SYS-M in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for CD2-SYS-M?
Send the part number CD2-SYS-M, the quantity, the full option string or instrument serial number, any certificate needs and the delivery location so we can prepare an accurate quotation.


















Reviews
There are no reviews yet.