Brand:

Beamex 9010900 DMT40 Dirt and Moisture Trap 40 bar

Description

Beamex 9010900 DMT40 dirt and moisture trap overview

The Beamex DMT40 dirt and moisture trap, order code 9010900, protects calibration equipment against contamination. Process instruments can contain moisture and dirt that could travel into a pressure source or calibrator during pneumatic calibration, and the trap collects those impurities from the device under test before they reach the equipment.

DMT40 is used in pneumatic applications up to 40 bar (580 psi) with air as the pressure medium. Liquids are not supported. It comes with a Bx G1/8 male fitting for Beamex 40 bar hoses and a stand that doubles as a manifold with three output connectors.

This page describes Beamex 9010900 for buyers who need the exact order code. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key features of the DMT40 dirt and moisture trap

  • Collects dirt and moisture from the device under test
  • For pneumatic use up to 40 bar (580 psi), air only
  • Bx G1/8 male fitting for Beamex 40 bar hoses
  • Stand that works as a manifold with three output connectors
  • Supplied with 40 bar hose, seals, support plate and wall adapter in a hard case

Standard delivery and contents according to Beamex:

  • DMT40 with Bx G1/8 male fitting
  • Stand that also works as manifold with three output connectors
  • 40 bar / 600 psi pressure hose
  • Set of seals and gaskets
  • Support plate and wall adapter
  • User manual
  • Hard case

Technical specifications of Beamex 9010900

Order code 9010900
Maximum pressure 40 bar / 580 psi
Pressure medium Air (liquids not supported)
Fitting Bx G1/8 male for Beamex 40 bar hoses
Stand Doubles as manifold with three output connectors
Packing Hard case

All values are taken from Beamex documentation. Items not shown here are not stated in the manufacturer source and are therefore left out.

Typical applications in Oman and the GCC

Process instruments that come off a plant often carry moisture, oil residue or dirt. If that contamination enters a pump, controller or calibrator, it can damage seals and valves. Protective accessories such as the DMT40 dirt and moisture trap (9010900) are therefore common in calibration workshops that serve refineries, gas plants, utilities and manufacturing sites in Oman and the GCC.

They are used on the line between the device under test and the pressure source, so that impurities are collected before they reach expensive equipment.

Selection and compatibility notes for 9010900

Confirm the pressure rating and the medium. 9010900 is intended for pneumatic calibrations, so it should not be used with liquids. Match hose thread types to the fittings of the accessory before ordering.

Where several instruments are calibrated from different sources, consider whether a protective accessory is needed on each pressure line, and keep spare seals available.

Installation and commissioning

Fit the accessory in line between the device under test and the pump or calibrator, following the order shown in the Beamex manual. Check that seals are fitted and the connections are tight before applying pressure.

Pressurize slowly, check for leaks and release pressure before disconnecting. Always observe the restrictions listed by Beamex for 9010900.

Maintenance and care

Empty or clean the accessory as the manual instructs, and replace the seals when they wear. Contamination collected in the trap is the reason it exists, so inspect it regularly if you calibrate dirty instruments.

Keep a spare seal kit with the accessory to minimize downtime.

Related products and ordering notes

Beamex lists these related items, each with its own order code:

  • 8003290 seal kit for DMT40 and DMT210
  • 8009600 vent valve for 40 bar pressure hoses
  • 9010920 CS40 calibration stand
  • 9010910 DMT210 dirt and moisture trap

Beamex is a Finnish maker of calibration equipment, and its manuals and product pages are the reference for every figure on this page. Always check the manufacturer’s current documentation before putting any accessory or spare part into service.

Seven Star LLC works with industrial maintenance, procurement and calibration teams, so requests that include the full order code, the quantity and the delivery location can be answered quickly. Order codes are often the only reliable way to separate similar-looking accessories from different product generations.

Plants in the region usually plan calibration work around shutdowns, turnarounds and seasonal maintenance windows. Ordering accessories and spare parts well before the work starts avoids waiting for a missing seal, hose or cable when the plant is already offline, and it is cheaper than expediting a single item at the last minute.

Good calibration practice also depends on traceability. Records of the reference equipment, its certificate, the environmental conditions and the as-found and as-left results are what auditors and clients ask for. Accessories do not replace the calibration of the reference itself, but a worn hose, a leaking seal or a damaged cable can spoil an otherwise good measurement, which is why consumables should be replaced on a schedule rather than only after a failure.

When you compare quotations, make sure the order code is identical. Calibration accessories from the same manufacturer often differ only by thread, length or pressure rating, and a similar-looking item with a different code may not be compatible with your equipment. Keep the code on the purchase order, the goods receipt note and the maintenance record so that the same item can be reordered later.

Frequently asked questions about 9010900

What does the DMT40 9010900 do? It collects moisture and dirt from the device under test so they do not enter the pressure source or calibrator during pneumatic calibration.

What pressure can it be used at? Up to 40 bar (580 psi), with air as the pressure medium. Liquids are not supported.

What is delivered with it? The trap with a Bx G1/8 male fitting, a manifold stand, a 40 bar hose, seals and gaskets, support plate and wall adapter, user manual and hard case.

How are the seals replaced? Beamex lists seal kit 8003290 for DMT40 and DMT210, containing the O-rings and bonded seals required.

Is there a high-pressure version? Yes. The DMT210, order code 9010910, is rated to 210 bar (3045 psi) and uses Bx 1215 fittings for 630 bar hoses.

Documents and quotation

The official Beamex POC8 automatic pressure controller user manual is attached to this page as a PDF. Its options list (page 71) includes the DMT40 dirt and moisture trap, order code 9010900. Send us the order code 9010900 and the serial number of your instrument and we will confirm fit and lead time in a written quotation.

Quote Beamex 9010900 exactly as written when you contact us, so that the correct item is quoted the first time. Delivery to Oman and to other GCC countries is arranged for each order, and any questions about packaging, documentation or alternative items can be raised in the same message.

Datasheets & Documents
  • PDF Datasheet Beamex POC8 User Manual (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 9010900 DMT40 Dirt and Moisture Trap 40 bar

Answers from our engineering team on installation, compatibility and integration.

01What does the DMT40 9010900 do?
It collects moisture and dirt from the device under test so they do not enter the pressure source or calibrator during pneumatic calibration.
02What pressure can it be used at?
Up to 40 bar (580 psi), with air as the pressure medium. Liquids are not supported.
03What is delivered with it?
The trap with a Bx G1/8 male fitting, a manifold stand, a 40 bar hose, seals and gaskets, support plate and wall adapter, user manual and hard case.
04How are the seals replaced?
Beamex lists seal kit 8003290 for DMT40 and DMT210, containing the O-rings and bonded seals required.
05Is there a high-pressure version?
Yes. The DMT210, order code 9010910, is rated to 210 bar (3045 psi) and uses Bx 1215 fittings for 630 bar hoses.