Brand: ifm
ifm LK3123 Level Sensor, 472 mm Probe, 4-20 mA, IO-Link
Description
ifm LK3123 Level Sensor, 472 mm Probe, 4-20 mA, IO-Link
The ifm LK3123 is an electronic level sensor with a 472 mm probe, an active range of 390 mm and a resolution of 5 mm. It measures water, hydrous coolants and oils with a measuring error of plus or minus 5 percent of the final value and repeatability of plus or minus 2. A 4-digit LED display shows the level.
Outputs are switching, 4 to 20 mA (invertible) and IO-Link. The wetted material is PP, the medium temperature is 0 to 35 degrees Celsius, or up to 60 degrees Celsius with the climatic tube E43101, and protection is IP67. Seven Star LLC supplies the LK3123 in Oman and the GCC as an independent supplier in Muscat.
LK3123 technical specifications
The table lists the values published by the manufacturer for the LK3123. Where a parameter has several operating modes, the headline value is shown; the full parameter list is in the manufacturer documentation.
| Parameter | Specification |
|---|---|
| Manufacturer / part number | ifm electronic / LK3123 |
| Resolution [mm] | 5 |
| Dimensions [mm] | Ø 16 |
| Probe length L [mm] | 472 |
| Active range A [mm] | 390 |
| Media | hydrous coolants; oils; oil-based media; water; media similar to water |
| Medium temperature [°C] | 0 to 35 (with climatic tube E43101: 35 to 60 °C) |
| Operating voltage [V] | 18 to 30 DC |
| Current consumption [mA] | < 50 |
| Output signal | switching signal; analogue signal; IO-Link |
| Electrical design | PNP/NPN |
| Output function | normally open / normally closed (parameterisable) |
| Permanent current rating of switching output DC [mA] | 200 |
| Analogue current output [mA] | 4 to 20, invertible |
| Max. load [Ω] | 500 |
| Repeatability | ± 2 |
| Measuring error [% of the final value] | ± 5 |
| Communication interface | IO-Link |
| Ambient temperature [°C] | 0 to 60 |
| Protection | IP 67 |
| Weight [g] | 372 |
| Materials | stainless steel (304/1.4301); stainless steel (316L/1.4404); FKM; NBR; PBT; PC; PA; PP; TPV |
| Materials (wetted parts) | PP |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
| MTTF [years] | 194 |
How the LK3123 works
The LK3123 is a capacitive level probe: the measured medium changes the capacitance between the electrodes in the probe, and the electronics convert the covered length into a level value. The device shows the level on its LED display, and the switching output can be set to a level threshold in 5 mm steps within the active range. The probe is suited to water-based liquids, oils and coolants with a dielectric constant above the stated limit, but not to highly conductive, adhering or acidic media.
Where the LK3123 fits and related parts
The LK3123 is a fixed-length continuous rod, comparable with the LK1022 in our range. For longer or hotter tanks the LR3000 guided wave radar is an alternative.
Selection and ordering checklist for the LK3123
Work through the points below before you confirm the order, so that the LK3123 you receive is the one your machine or plant needs.
- Confirm 472 mm probe and 390 mm active range
- Check media: water, coolants, oils
- Check temperature, and the need for the climatic tube
- Choose switching or analogue output
- Confirm 18 to 30 V DC
The manufacturer lists this article under the type designation Electronic level sensor, LK0472B-B-00KLPKG/US. The article number LK3123 is the reference to quote when ordering, and the type designation is useful for technicians who compare the label on an installed unit.
Installation, commissioning and maintenance
Mount the probe vertically through a tank opening with the accessory fitting suited to the application, leaving the stated inactive zones at the top and bottom in mind when you choose the length. Keep the probe away from baffles and fill streams, and use the climate tube accessory when the medium is warmer than the base limit. At commissioning, fill to a known level, adjust the reference point and confirm the switching output at both thresholds. Over time, clean the probe if the coolant forms a film or sludge, and check that the cable is routed away from motor leads.
Typical applications in Oman and the GCC
Coolant tanks on machine tools, hydraulic reservoirs and lubricant tanks. In Oman and the GCC the temperature limit needs attention in hot rooms.
Level sensors in tanks exposed to Gulf summers must tolerate hot product, condensation on cold nozzles and long periods without attention. Plan a periodic proof test of the alarm point, and record the output state at known levels during commissioning.
LK3123 compared with related ifm types
The table places the LK3123 next to neighbouring types in the same application group, so you can see whether a sibling would suit the job better.
| Part number | Key characteristics | Note |
|---|---|---|
| LR3000 | GWR, G 3/4, 100-1600 mm probe, 4-20 mA, IO-Link | Related type |
| LMT110 | Point level, G 1/2 cone, -40 to 100 C, 40 bar, IO-Link | Related type |
| LK3123 | Continuous capacitive, 472 mm, 4-20 mA, IO-Link | This page |
| LMT100 | Point level sensor | Related type |
| LMC510 | Capacitive point level sensor | Related type |
| LK1022 | Continuous level sensor | Related type |
| LR2750 | Guided wave radar | Related type |
Information to send with an RFQ for the LK3123
To prepare an accurate offer for the LK3123, please include the following with your enquiry:
- Medium and its temperature profile
- Required probe length and tank depth
- Tank pressure and mounting fitting
- Switching output or IO-Link requirement
- Quantity and delivery location
Storage, handling and spares for the ifm LK3123
Keep ifm LK3123 units in their original packaging until they are mounted. Store them indoors in a dry, dust-free room, away from direct sun and condensation. Panel shops in Oman and the GCC often hold stock in warehouses that get very hot in summer, so check that storage temperature stays within the limits given in the manufacturer datasheet.
- Check the label and order code on every unit against the drawing before it goes into the panel.
- Use the correct tool and tightening torque for the terminals, as given in the instructions supplied with the product.
- Keep a small number of spare units for each rating used on site, so that a failed or damaged part can be replaced without waiting for a new shipment.
- Record the order code in the panel documentation and the as-built drawings, so that maintenance teams can reorder the same part later.
When you plan spares for a project, group the ifm LK3123 with the other parts of the same panel in one RFQ. This keeps delivery dates aligned and makes it easier to confirm stock for the whole bill of materials at once.
Documents and quotation
The official ifm data sheet for the LK3123 (document LK3123-03, English, issued 13 April 2023) is attached on this page as a PDF. It sets out the electrical data, the output function, the operating conditions, the approvals and the dimension drawing for this article. Check these values and the wiring diagram against your application before ordering, then send us the quantity and the delivery location for a quotation.
Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC and is not affiliated with the manufacturer; the name ifm is used only to identify the product. Prices are not shown on the page, so send the part number, the quantity and the delivery location to receive a quotation.
Other Models in the Ifm61 Level Range
Seven Star LLC supplies models from the Ifm61 Level range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ifm LR3000 Guided Wave Radar Level Sensor, G 3/4, 100-1600 mm | Automation Accessories | View details |
| ifm LMT110 Point Level Sensor, G 1/2 Sealing Cone, PEEK, IP69K | Automation Accessories | View details |
| ifm LK3123 Level Sensor, 472 mm Probe, 4-20 mA, IO-Link | Automation Accessories | You are viewing this model |
Datasheets & Documents
- Datasheet ifm LK3123 Data Sheet (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.
Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.
ifm company profile
| Founded | 1969, Essen, Germany |
|---|---|
| Founders | Robert Buck and Gerd Marhofer |
| Headquarters | Essen, Germany |
| Ownership | Family-owned |
| Product families | Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters |
Milestones
- 1969: ifm is founded in Essen.
- 2001: The founders' sons take over management.
ifm sensors listed on this page
ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:
- O1D100: laser distance sensor for position and distance measurement
- PN7093: pressure sensor with local display
- NG5021: inductive proximity sensor with NAMUR output
Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.
ifm products we list
Ordering ifm sensors: what we need
Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.
Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.
Browse ifm products by category: Sensors & Transmitters, Pressure Instrumentation.
FAQ
Questions about the ifm LK3123 Level Sensor, 472 mm Probe, 4-20 mA,
Answers from our engineering team on installation, compatibility and integration.
01What is the probe length of the ifm LK3123?
472 mm, with an active range of 390 mm. This is the value published by the manufacturer for the LK3123; confirm details before ordering.
02What is the temperature limit of the LK3123 medium?
0 to 35 degrees Celsius, or 35 to 60 with the climatic tube E43101.
03What outputs does the LK3123 have?
Switching, 4 to 20 mA and IO-Link. This is the value published by the manufacturer for the LK3123; confirm details before ordering.
04What is the resolution of the LK3123?
5 mm. This is the value published by the manufacturer for the LK3123; confirm details before ordering.
05What are the wetted parts of the LK3123?
PP. This is the value published by the manufacturer for the LK3123; confirm details before ordering.