Brand: Parker
Parker 944919Q iProtect GLF Size 5 Return Line Element 20 um
Description
944919Q iProtect GLF size 5 return line element, 20 micron
The Parker 944919Q is a replacement element for the GLF Series tank top return line filter, size 5, in the Parker iProtect low pressure range. It is the length 1 element with 20 µm Quantumfibre glass media and nitrile seals, supplied without an integral bypass cartridge. The 20QI media code in the Parker ordering table is the coarsest of the four ratings (2, 5, 10 and 20 µm), which makes the 944919Q the high-flow, low-restriction choice for return lines on large reservoirs where the aim is to keep gross contamination out of the tank rather than to reach a very clean fluid.
What the 944919Q is
The GLF filter sits on top of a hydraulic tank with its element hanging down into the oil. Return oil from the system enters the head, passes through the element and drains into the reservoir. Size 5 is the largest GLF frame, with a nominal flow figure for length 1 of 700, 800, 900 and 1100 l/min for the 02QI, 05QI, 10QI and 20QI media respectively at 30 cSt. For the 20 µm element 944919Q the brochure value is therefore 1100 l/min at that viscosity. The Parker product page quotes a flow range from 0 to 1700 l/min for the element family, which covers the longest size 5 elements.
Technical specifications of 944919Q
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Parker 944919Q |
| Series | iProtect GLF replacement elements |
| For use with | GLF size 5 tank top return line filter |
| Element length | Length 1 |
| Micron rating | 20 µm (media code 20QI) |
| Filter media | Quantumfibre glass media |
| Seal material | Nitrile |
| Bypass in element | None (element without bypass) |
| Operating pressure | 10 bar (145 psi) |
| Operating temperature | -40 to 100 °C (page), nitrile range -40 to 110 °C in the brochure for the assembled filter |
| Fluid | Hydraulic oil |
| Rating method | Multipass test to ISO 16889 |
Reading the element table for 944919Q
In the GLF brochure, spare elements for size 5 are listed in a table with media down the side and length across the top. The 944919Q is the entry for 20QI at length 1. The neighbouring numbers are 944920Q for length 2 and 944921Q for length 3 in the same media, while the finer ratings for length 1 are 944910Q (2 µm), 944913Q (5 µm) and 944916Q (10 µm). The same table shows that size 5 elements are listed without a bypass setting, and the brochure describes the reinforced polyamide bypass cartridge, with a 1.7 bar opening pressure, only for sizes 1 to 4.
Selecting between the 20, 10, 5 and 2 micron elements
- Choose 20 µm when high flow and low pressure drop matter most, for example on large return manifolds from presses and mobile equipment.
- Choose 10 µm (944916Q) as a general purpose return line level.
- Choose 5 µm (944913Q) where servo or proportional valves are fed from the same tank.
- Choose 2 µm (944910Q) only if the pump and valve manufacturers call for it, accepting a lower flow figure per element.
- Match the length to the filter: length 1, 2 or 3 are different elements and are not interchangeable.
Installation, replacement and service of GLF elements
An element change on a tank top filter starts with stopping the pump and relieving any residual pressure in the return line. The cover is removed, the old element is lifted out with the contamination it holds, and a new element with fresh seals is fitted. GLF seal kits are sold separately for each size, in nitrile and fluoroelastomer, and a pressure gauge or electrical pressure switch can be added to warn that the element is blocked. The brochure lists indicator settings of 1.2 bar as standard and 2.5 bar as an option. A filter without a working indicator should be changed on a time basis, and an element that was removed because the fluid was very dirty should prompt a look at the breather, the reservoir and the system seals.
Take care that the replacement is the same size and length as the one removed. The GLF 5 head will accept a length 1, 2 or 3 element, but the amount of filtering area and flow capacity differ, so check the code on the name plate or in the maintenance record.
Typical applications in Oman and the GCC
Tank top return line filters of this size are found on large hydraulic power packs, marine and offshore steering and deck equipment, hydraulic presses and mobile or heavy lifting machinery. The Parker page lists oil and gas, marine, mining, power and construction among its industries. In Oman and the Gulf, dust, sand and high ambient temperatures put heavy demands on reservoir filtration, and operators often hold spare elements for planned changes during maintenance windows.
GLF size 5 element family
| Media | Length 1 | Length 2 | Length 3 |
|---|---|---|---|
| 02QI (2 µm) | 944910Q | 944911Q | 944912Q |
| 05QI (5 µm) | 944913Q | 944914Q | 944915Q |
| 10QI (10 µm) | 944916Q | 944917Q | 944918Q |
| 20QI (20 µm) | 944919Q | 944920Q | 944921Q |
Information to send with an RFQ
- Part number 944919Q and the quantity.
- The GLF filter code from the head name plate.
- Seal material and fluid type in the tank.
- Whether you also need seal kits or a pressure indicator.
- Delivery location in Oman or the GCC.
Storage, handling and spares for the Parker 944919Q
Keep Parker 944919Q elements sealed in their original bags and boxes until installation. Store them flat or upright as marked on the carton, indoors, away from dust, moisture, solvents and direct sun. In hot warehouses in Oman and the GCC, check that seals and gaskets are not stored above the temperature limits given by the manufacturer.
- Check the part number, micron rating and seal material on every element against the housing data plate before fitting.
- Replace elements when the differential pressure indicator or the site maintenance schedule calls for it, not only when flow drops.
- Fit new O-rings or gaskets with each element change where the instructions require it.
- Keep at least one spare element for each housing in service, so that a change-out does not wait for a shipment.
When you send an RFQ for the Parker 944919Q, list the housing model, required micron rating, media and quantity of spare elements, so the complete filtration scope can be quoted together.
Documents and quotation
The Parker GLF and GLI brochure is attached on this page and contains the element, seal kit and indicator tables used in this description.
Send the part number and your filter details and we will prepare a quotation. Seven Star LLC supplies hydraulic filtration spares in Oman and the GCC.
Datasheets & Documents
- Catalog Parker GLF and GLI iProtect Filter Brochure Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.
Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.
Parker company profile
| Founded | 1917, Cleveland, Ohio, USA, by Arthur L. Parker |
|---|---|
| Headquarters | Cleveland area, Ohio, USA |
| Ownership | Public company, New York Stock Exchange (PH), listed since 1964 |
| First product | Pneumatic brake system for trucks and buses |
| Product families | Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings |
Milestones
- 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
- 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
- 1957: Parker acquires Hannifin and becomes Parker Hannifin.
- 1964: The shares are listed on the New York Stock Exchange.
Parker product lines listed here
Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.
Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.
Where Parker components are used
Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.
Parker products we list
Ordering Parker parts: what we need
Parker part numbers are long and every character counts. Please send:
- Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
- Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
- Filter elements: element number and the housing model it fits
A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.
Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.
Browse Parker products by category: Solenoid Valve, Filtration Elements, Pumps.
FAQ
Questions about the Parker 944919Q iProtect GLF Size 5 Return Line
Answers from our engineering team on installation, compatibility and integration.
01What is the 944919Q used for?
It is a 20 micron replacement element for the Parker iProtect GLF size 5 tank top return line filter, length 1. It cleans hydraulic oil returning to the reservoir.
02Does the 944919Q include a bypass valve?
No. In the Parker brochure the size 5 elements are listed without bypass. Sizes 1 to 4 use elements with a bypass cartridge opening at 1.7 bar.
03What is the flow rating of the 944919Q?
The brochure gives 1100 l/min for GLF5 length 1 with 20QI media at a viscosity of 30 cSt. The product page quotes 0 to 1700 l/min for the element family.
04Which other elements are in the same family?
For size 5 length 1 the finer media are 944910Q (2 micron), 944913Q (5 micron) and 944916Q (10 micron). Lengths 2 and 3 in 20 micron are 944920Q and 944921Q.
05Which fluids and temperatures are allowed?
The product page lists hydraulic oil, an operating pressure of 10 bar and a temperature of -40 to 100 degrees C. Nitrile seals suit mineral and vegetable oils and some synthetic oils.