Brand:

Parker 370L322A Replacement Filter Element, 10 um, H300

Description

370L322A replacement element for Parker H300 high pressure filters

The Parker 370L322A is a disposable microglass replacement element for the Model 300 housing of the Parker H100/200/300 high pressure hydraulic filter family. It is rated at 10 µm, is 322 mm long with a 94 mm diameter, uses nitrile seals and is intended for mineral oil systems only. Parker lists it on its product page as part 7021010010 with model number 370L322A, and the code is the one printed on the element and on the filter name plate, so it is the number to quote when you need a like-for-like change-out. It is used in pressure-line filters on power units, test rigs and hydraulic skids.

How the 370L322A code is built

The H-type ordering tables in the Parker brochure build an element code from housing, filter type, option, element type, length, degree of filtration and seal. Read against those tables, Parker 370L322A breaks down as follows.

Position Code Meaning
Housing 3 Model 300 (rated up to 350 l/min)
Filter type 7 Inorganic fibre disposable element
Option 0 Standard
Element type L Mineral oil only (10 and 20 µm ratings only)
Length 3 Length 3, available only in Model 300
Degree of filtration 22 GDH10, 10 µm class
Seal A Nitrile (NBR)

The decoding agrees with the data on the Parker product page, which shows 10 µm, microglass media, length 322 mm, diameter 94 mm and nitrile seals. If an element or name plate you are matching carries a different letter or number in any position, it is a different element and should be confirmed before ordering.

Technical specifications of Parker 370L322A

Parameter Specification
Manufacturer / part number Parker 7021010010 (model number 370L322A)
Series Replacement elements for H100/200/300 high pressure filters
For use with H300 (Model 300 housing)
Filter element type Microglass, disposable
Micron rating 10 µm
Size Length 3
Length 322 mm
Diameter 94 mm
Seal material Nitrile
Fluid compatibility Mineral oil only
Filter type High pressure

Where the 370L322A sits in an H300 filter

The Model 300 housing is the largest of the H-type range. The brochure rates it for flow up to 350 l/min and a working pressure of 414 bar, with 1¼ inch and 1½ inch threaded or flanged ports and manifold mounting options. The element is pushed onto an adaptor spigot inside the bowl, so the oil passes from the outside of the pleated pack to the inside. Contamination is therefore trapped in the pleats while the bowl and head are not exposed to the clean side flow. Length 3 is the longest element offered for Model 300 and gives the largest filtering area in that housing, which is why it is chosen for continuous duty and for fine filtration at high flow.

The brochure lists a collapse pressure of 20 bar for disposable elements and 210 bar for the high strength version. The Parker 370L322A is a disposable inorganic fibre element, so a blocked element must not be left in service behind a closed bypass. Model 300 housings carry a bypass setting of 5.0 bar in the ordering table, and a differential pressure indicator or switch is the normal way to know that the element needs replacing before the bypass opens.

Selecting and ordering the right 370L322A

  • Check the housing: the element is for Model 300 only. Model 100 and Model 200 use shorter, smaller elements.
  • Confirm the fluid. The L element type is for mineral oil only. Water glycol, phosphate ester or ammonia-containing fluids need other element types.
  • Match the micron rating. 370L322A is a 10 µm element; a finer or coarser rating changes the code in the degree-of-filtration position.
  • Match the seals. A nitrile seal is code A; EPR or fluoroelastomer seals are different codes in the same table.
  • Match the length. Length 3 is 322 mm; length 1 and length 2 are shorter and not interchangeable in the same bowl.
  • Read the code from the old element or the housing name plate rather than from memory.

Changing the element and keeping the filter healthy

The brochure gives a clear service sequence for H-type filters. Depressurise the circuit, remove the bowl using the hexagon, pull the old element off the adaptor, remove the head-to-bowl seal and keep the back-up ring for reuse. The bowl is cleaned, the back-up ring is refitted on the bowl nose followed by a new head-to-bowl seal, which is wetted, and the bowl is filled about halfway with clean fluid. The new element is pushed onto the adaptor and the bowl is refitted to the torque shown for the model. The brochure lists 136 Nm for the bowl on Model 200 and 300 housings and 38 Nm for the indicator. Disposable elements must not be cleaned or reused.

For a filter with no indicator, the brochure suggests changing the element after 10 hours and again after 100 hours on new equipment, then every 500 hours as a general interval, and shorter intervals in hostile conditions. These are guide values; an indicator reading and oil analysis give a better basis in service.

Typical applications in Oman and the GCC

High pressure filters with Model 300 housings are used downstream of the pump on hydraulic power units, presses, test benches and industrial hydraulic skids where servo or proportional valves need protection. In Oman and the Gulf, such systems run in warm workshops and outdoor plant areas, where dust, sand and heat accelerate fluid contamination and shorten element life. Operators in oil and gas, power generation, desalination and heavy fabrication keep spare elements on the shelf so that a change-out can be done in a planned stop rather than after a bypass event.

H100, H200 and H300 range at a glance

Model Flow up to Working pressure Ports
Model 100 100 l/min 414 bar ½ and ¾ inch threaded, side manifold
Model 200 250 l/min 414 bar ¾, 1 and 1¼ inch threaded, flanged, manifold
Model 300 350 l/min 414 bar 1¼ and 1½ inch threaded, flanged, manifold
Model SH100 100 l/min 690 bar ½ and ¾ inch threaded

Information to send with an RFQ

  • Part number 370L322A or 7021010010, with the quantity required.
  • The filter housing name plate code and model number.
  • Working fluid and operating temperature.
  • Whether the old element was nitrile sealed and 10 µm rated.
  • Delivery location in Oman or the GCC.

Documents and quotation

A brochure covering the H-type high pressure filter range is attached on this page, including the ordering tables used to decode the 370L322A. It is an older edition, so check the housing name plate for the exact configuration.

Send the part number and your housing details and we will return a quotation. Seven Star LLC supplies hydraulic filtration spares in Oman and the GCC.

Datasheets & Documents
  • PDF Catalog Parker H100/200/300 High Pressure Filter Brochure Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.

Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.

Parker company profile

Founded 1917, Cleveland, Ohio, USA, by Arthur L. Parker
Headquarters Cleveland area, Ohio, USA
Ownership Public company, New York Stock Exchange (PH), listed since 1964
First product Pneumatic brake system for trucks and buses
Product families Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings

Milestones

  • 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
  • 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
  • 1957: Parker acquires Hannifin and becomes Parker Hannifin.
  • 1964: The shares are listed on the New York Stock Exchange.

Parker product lines listed here

Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.

Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.

Where Parker components are used

Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.

Parker products we list

Family Examples
Solenoid Valves 7341NAKBHNM0 Lucifer Series Solenoid Valve, Lucifer 322K4706 2-Way Solenoid Valve, Lucifer 341N01 NAMUR Solenoid Valve, Lucifer 341N22 SOLENOID VALVE, Lucifer 341N31 NAMUR Solenoid Valve, Lucifer E131K03 Solenoid Valve
Filtration Elements 9000040001 Coalescing Filter Element
Pumps P51A478BEY25-07-ZY Hydraulic Gear Pump
Pipes & Fittings Triple-Lok 37° Flare Tube Fitting

Ordering Parker parts: what we need

Parker part numbers are long and every character counts. Please send:

  • Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
  • Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
  • Filter elements: element number and the housing model it fits

A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.

Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.

FAQ

Questions about the Parker 370L322A Replacement Filter Element, 10 um,

Answers from our engineering team on installation, compatibility and integration.

01What filter housing does the 370L322A fit?
The 370L322A is a replacement element for the Model 300 housing of the Parker H100/200/300 high pressure filter family. It is not interchangeable with the shorter elements used in Model 100 or Model 200 housings.
02What does 370L322A mean?
Using the Parker H-type ordering tables, 3 is the Model 300 housing, 7 is inorganic fibre disposable, 0 is standard, L is mineral oil only, 3 is length 3, 22 is the 10 micron GDH10 class and A is nitrile seals.
03What fluids can this element be used with?
It is an L-type element, so it is for mineral oil only. Other fluids such as water glycol or phosphate ester need different element types and should be checked before ordering.
04What are the dimensions of the 370L322A?
The Parker product page gives a length of 322 mm and a diameter of 94 mm. It is the Length 3 element, the longest size offered for the Model 300 housing.
05Can the element be cleaned and reused?
No. The brochure states that disposable elements must not be cleaned or reused. Replace the element and the head-to-bowl seal, and watch the clogging indicator so that the element is changed before the bypass opens.