Brand: Parker
Parker 8A-V8LN-SS V Series Needle Valve 1/2″ A-LOK
Description
8A-V8LN-SS V8 stainless steel needle valve with 1/2" A-LOK compression
The Parker 8A-V8LN-SS is an inline (straight-through) needle valve from the V Series, an integral-bonnet instrument valve in 316 stainless steel with 1/2" A-LOK® compression ports, a needle (2-1/2° taper) all-metal stem and the standard PTFE stem packing. Parker designs the V Series for positive, leak-tight shut-off and for regulating fluids in process, power and instrumentation lines, and Parker 8A-V8LN-SS belongs to the V8 body size, which has a 7.9 mm (0.312 in) orifice. It is rated 5000 psig (345 bar) in stainless steel and, with this stem and packing, covers -65°F to 450°F (-54°C to 232°C).
Seven Star LLC supplies Parker 8A-V8LN-SS in Oman and the GCC for instrument panels, sample systems, gauge isolation and utility lines. The sections below decode the part number, list the verified data from the Parker V Series needle valve catalogue and explain how to select, install and maintain the valve.
How the part number 8A-V8LN-SS is built
Parker builds V Series part numbers from six characteristics in a fixed order: inlet port, outlet port, valve series, stem type with pattern, stem seal and body material. Decoding 8A-V8LN-SS gives the following.
| Code | Meaning for 8A-V8LN-SS |
|---|---|
| 8A | Inlet and outlet port type and size: A-LOK® double-ferrule compression tube end for 1/2" tube (when both ports are the same the outlet code is left out) |
| V8 | Valve series (body size): V8, orifice 0.312 in (7.9 mm) |
| LN | Pattern L: L = inline; stem type N: needle (2-1/2° taper) all-metal |
| (blank) | Stem seal: PTFE packing as standard; BN, EPR or V in this position would mean an O-ring seal in nitrile, ethylene propylene or fluorocarbon rubber |
| SS | Body material: 316 stainless steel (other codes are S steel, M Monel® Alloy 400, B brass) |
Two ordering options appear at the end of V Series numbers. A colour letter (W, B, G, R or Y) after the body material selects a coloured round handle in place of black, and the suffix -C3 means the valve has been cleaned and assembled for oxygen service to Parker specification ES8003. Neither suffix is part of the standard number 8A-V8LN-SS, so state any option clearly in your enquiry.
Parker 8A-V8LN-SS technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Parker / 8A-V8LN-SS |
| Product family | V Series needle valve, integral bonnet |
| Body material | 316 stainless steel (ASTM A 182 Type F316) |
| Pattern | inline (straight-through) |
| Port connections | 1/2" A-LOK® compression, inlet and outlet |
| Stem type | needle (2-1/2° taper) all-metal |
| Stem seal | PTFE packing |
| Orifice | 0.312 in (7.9 mm) |
| Cv (inline) | 1.05 |
| xT factor (inline, ISA S75.02) | 0.83 |
| Maximum pressure | 5000 psig (345 bar) CWP, stainless steel body |
| Temperature range | -65°F to 450°F (-54°C to 232°C) |
| Dimensions A and B (nuts finger tight) | 1.53 in (38.9 mm) each |
| Handle | Aluminium T-bar (N and R stems) |
| Mounting | Panel mountable; panel nut ordered separately |
| Factory test | 100 % factory tested |
All values above are taken from Parker catalogue 4110-NV for the V Series and from the Parker product page for 8A-V8LN-SS. Dimensions are reference values and may change; dimensions for A-LOK® and CPI™ ends are measured with the nuts only finger tight.
How the 8A-V8LN-SS controls flow
Inside the 8A-V8LN-SS the stem is driven down onto a seat machined in the body. The needle stem gives a very small, controllable area change as the tapered tip enters the seat, which is why it is used for regulation as well as shut-off. Parker hardens the stem to a different level than the cold-formed body threads, a differential-hardness design that improves cycle life and keeps adjustment smooth over many turns.
Flow capacity is described by Cv and by the xT choked-flow factor tested to ISA S75.02. For the inline (straight-through) pattern of this valve Parker lists Cv 1.05 and xT 0.83; the angle pattern of the same body shows Cv 1.28 and xT 0.80. Gas flow becomes choked when the pressure drop divided by the inlet pressure reaches xT, so a lower xT means the valve chokes sooner. With a Cv of 1.05 the 8A-V8LN-SS is a metering and isolation valve rather than a high-flow line valve.
As the largest size in the V range with 1/2" tube ends and a 7.9 mm orifice it is used where an instrument-grade valve must still pass meaningful flow, such as a bypass or a vent on a skid.
Where the 8A-V8LN-SS fits in the system
V Series valves are used as isolation, vent, drain, bypass and metering points in small-bore stainless steel instrument tubing. The 8A-V8LN-SS is typically installed close to a transmitter, gauge, sample take-off or analyser inlet, normally upstream of a manifold or between the process tubing and the instrument. Because the valve is panel mountable it can also be fixed through a panel so the handle sits on the front while the tube connections stay behind.
Within the V Series the same family includes 4Z-V4LK-SS, 4A-V4LN-SS, 4Z-V4AK-SS, 4M-V4LN-SS, 2A-V2LN-SS. They share the 316 stainless steel integral-bonnet design and differ in body size, port type, pattern and stem tip, so the right sibling for a job depends on flow and connection rather than on a different technology. For tube connections, Parker A-LOK® and CPI™ fittings such as the 4MSC4N-316 male connector and the 4SC4-316 union are the natural companions, and instrument manifolds of the H Series sit between the valve and a transmitter.
The V8 body uses an aluminium T-bar handle on N and R stems; this gives more leverage for fine adjustment but needs more clearance than a round knob.
Selection checklist for the 8A-V8LN-SS
- Port type and size: confirm the tubing outside diameter and whether the line uses A-LOK® (double ferrule), CPI™ (single ferrule) or NPT threads. The 8A-V8LN-SS has 1/2" A-LOK® compression ports.
- Flow: compare the required Cv with the 1.05 of this valve and check the xT value for gas service.
- Stem tip: choose needle (N) for regulation, blunt (R) for hard-seat duty where wire draw is a risk, or PCTFE (K) for bubble-tight shut-off; this valve has a needle.
- Temperature and pressure: this stem and packing combination is rated -65°F to 450°F (-54°C to 232°C) and 5000 psig (345 bar), and the lowest rating of any component sets the limit.
- Packing: PTFE packing is standard; elastomer O-ring seals in nitrile, ethylene propylene or fluorocarbon are available by changing the seal code in the part number.
- Pattern: choose inline where the tubing run stays straight and angle where the line turns, as in the sibling model with the opposite pattern code.
- Cleaning: state if oxygen-clean (-C3) preparation or a coloured handle is needed so the number is quoted complete.
Installation, commissioning and maintenance of the 8A-V8LN-SS
- Check the flow arrow or port markings, the tube end condition and that the tube is square-cut, deburred and fully inserted before tightening nuts.
- Support the tubing on both sides so that vibration and line weight are not carried by the valve body.
- Open and close the stem slowly during commissioning and pressure-test the connections with the system fluid or an inert gas before starting the process.
- If the stem packing weeps in service, tighten the packing nut slightly; the PTFE stem seal is designed to be adjusted in line.
- For a rebuild, Parker lists a maintenance kit built from the valve series, stem type and body material, for this valve in the form KIT-V8N-SS, containing a stem, packing, washers and a packing nut.
- Keep a record of the part number 8A-V8LN-SS and install date so that spare handles, panel nuts and kits can be matched later.
Parker lists coloured round handles for the series, stainless steel and aluminium T-bar handles and panel mounting nuts as separate components, which is useful for tagging different services on a crowded panel.
Typical applications in Oman and the GCC
In Oman and the wider GCC, small stainless steel instrument valves such as the 8A-V8LN-SS are found on oil and gas wellhead and flowline panels, gas compression skids, power plant sample and chemical dosing systems, desalination plants and petrochemical units. 316 stainless steel resists chloride attack far better than carbon steel or brass, which matters on coastal sites where salt-laden air and high humidity attack exposed hardware. Dust and heat also make smooth, enclosed stems and PTFE packing valuable, because they keep sand and dirt away from the thread area and hold their seal over a wide temperature span.
Typical uses include isolation of pressure gauges and transmitters, calibration and purge connections, instrument air branches, sampling points and vent or drain valves on analyser panels. The 1/2" A-LOK® compression port arrangement and 7.9 mm orifice make it suited to light-duty regulation and positive isolation, not to bulk process flow.
V Series variants compared with the 8A-V8LN-SS
| Part number | Body | Ports | Pattern | Stem | Orifice (mm) | Cv |
|---|---|---|---|---|---|---|
| 4Z-V4LK-SS | V4 | 1/4" CPI™ compression | Inline | PCTFE | 4.5 | 0.45 |
| 4A-V4LN-SS | V4 | 1/4" A-LOK® compression | Inline | Needle | 4.5 | 0.43 |
| 4Z-V4AK-SS | V4 | 1/4" CPI™ compression | Angle | PCTFE | 4.5 | 0.58 |
| 4M-V4LN-SS | V4 | 1/4" male NPT | Inline | Needle | 4.5 | 0.43 |
| 2A-V2LN-SS | V2 | 1/8" A-LOK® compression | Inline | Needle | 2.0 | 0.12 |
| 6A-V6LN-SS | V6 | 3/8" A-LOK® compression | Inline | Needle | 5.8 | 0.55 |
| 8A-V8LN-SS | V8 | 1/2" A-LOK® compression | Inline | Needle | 7.9 | 1.05 |
| 4F-V6LN-SS | V6 | 1/4" female NPT | Inline | Needle | 5.8 | 0.55 |
The table shows how the body size drives capacity: Cv rises from 0.12 for the V2 to 1.05 for the V8 in the inline pattern. Use it as a first screening aid, then confirm connection codes against the full ordering chart before placing an order for the 8A-V8LN-SS or any alternative.
Information to send with an RFQ for 8A-V8LN-SS
- Full part number 8A-V8LN-SS and the quantity required.
- Tubing outside diameter and material, or pipe thread type, at both ends.
- Fluid, minimum and maximum operating temperature and operating pressure.
- Whether oxygen cleaning, a coloured handle, a panel nut or a maintenance kit is needed with the valve.
- Project name and required delivery location in Oman or the GCC.
Documents and quotation
The official Parker Instrumentation Products Division catalog 4110-NV (June 2019, English) is attached on this page as a PDF and covers the V Series needle valve used for the Parker 8A-V8LN-SS. It gives the V Series pressure and temperature ratings, the orifice and flow coefficient (Cv) values, the stem tip and packing options, the CPI, A-LOK and NPT end connections, the materials of construction and the full ordering code. Check the end connection, the seat material and the rating against your line before ordering, then send us the quantity and the delivery location for a quotation.
Seven Star LLC supplies 8A-V8LN-SS in Oman and the GCC and can also quote matching A-LOK® and CPI™ fittings, tubing, manifolds and ball valves for the same line. Send your RFQ with the details above.
Other Models in the Parker V Series Needle Valve Range
Seven Star LLC supplies models from the Parker V Series Needle Valve range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Parker 4Z-V4LK-SS V Series Needle Valve 1/4″ CPI | Automation Accessories | View details |
| Parker 4A-V4LN-SS V Series Needle Valve 1/4″ A-LOK | Automation Accessories | View details |
| Parker 4Z-V4AK-SS V Series Needle Valve 1/4″ CPI | Automation Accessories | View details |
| Parker 4M-V4LN-SS V Series Needle Valve 1/4″ male NPT | Automation Accessories | View details |
| Parker 2A-V2LN-SS V Series Needle Valve 1/8″ A-LOK | Automation Accessories | View details |
| Parker 6A-V6LN-SS V Series Needle Valve 3/8″ A-LOK | Automation Accessories | View details |
| Parker 8A-V8LN-SS V Series Needle Valve 1/2″ A-LOK | Automation Accessories | You are viewing this model |
Datasheets & Documents
- Datasheet Parker Needle Valves Catalog 4110-NV (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.
Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.
Parker company profile
| Founded | 1917, Cleveland, Ohio, USA, by Arthur L. Parker |
|---|---|
| Headquarters | Cleveland area, Ohio, USA |
| Ownership | Public company, New York Stock Exchange (PH), listed since 1964 |
| First product | Pneumatic brake system for trucks and buses |
| Product families | Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings |
Milestones
- 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
- 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
- 1957: Parker acquires Hannifin and becomes Parker Hannifin.
- 1964: The shares are listed on the New York Stock Exchange.
Parker product lines listed here
Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.
Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.
Where Parker components are used
Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.
Parker products we list
Ordering Parker parts: what we need
Parker part numbers are long and every character counts. Please send:
- Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
- Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
- Filter elements: element number and the housing model it fits
A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.
Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.
Browse Parker products by category: Solenoid Valve, Filtration Elements, Pumps.
FAQ
Questions about the Parker 8A-V8LN-SS V Series Needle Valve 1/2″ A-LOK
Answers from our engineering team on installation, compatibility and integration.
01What does the part number 8A-V8LN-SS mean?
It denotes 1/2" A-LOK® compression ports (code 8A), V Series body V8, inline pattern with a needle stem, standard PTFE stem seal and a 316 stainless steel body. The decoding table on this page lists each element.
02What pressure and temperature can the 8A-V8LN-SS handle?
The 316 stainless steel V Series body is rated 5000 psig (345 bar) CWP. With this stem and PTFE packing the temperature range is -65°F to 450°F (-54°C to 232°C), and the lowest-rated component sets the working limit.
03What is the flow capacity of the 8A-V8LN-SS?
Parker lists an orifice of 7.9 mm (0.312 in) and a Cv of 1.05 with xT 0.83 for this inline pattern, tested to ISA S75.02. It is a metering and isolation valve, not a high-flow line valve.
04Can the 8A-V8LN-SS be mounted on a panel?
Yes, V Series valves are panel mountable. The panel nut is supplied separately and the panel hole and maximum panel thickness depend on the body size, so check the catalogue dimensions for the V8 body.
05Which spare parts exist for the 8A-V8LN-SS?
Parker lists a stem maintenance kit by series, stem type and body material (for example KIT-V8N-SS), coloured handles, T-bar handles and panel nuts. Send the part number and we will confirm what is available.


















Reviews
There are no reviews yet.