- Automation & ControlView all 2,610 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Parker
Parker EPF4105QIHBT1MH202 iprotect High Pressure Filter 420 bar
Description
EPF4105QIHBT1MH202 EPF4 iprotect filter without bypass
The Parker EPF4105QIHBT1MH202 is a size 4 high pressure filter from the EPF iprotect range, which Parker introduced as a compact replacement for older pressure filters; the size 4 corresponds to the 38P. In this configuration the filter carries a 5 micron high-strength Microglass III element, a blocked (no) bypass, an electrical differential-pressure indicator and 1-1/4 inch SAE 6000M flange ports. With the bypass blocked every drop of oil is filtered, which is why Parker advises high-strength elements in that case. Seven Star LLC supplies the EPF4105QIHBT1MH202 in Oman and the GCC.
Decoding the part number EPF4105QIHBT1MH202
Following the ordering information: EPF4 is the size, 1 is the element length, 05QIH is the media (5 micron iprotect high-strength element) and B is nitrile seal. T1 selects the electrical indicator, M is the bypass and indicator setting code, which for no bypass gives a 5 bar indicator, and H20 is the SAE flange 1-1/4 inch 6000M connection. The closing 2 is the option for no bypass, available only with QIH elements. Compared with a standard QI element, which has a 25 bar collapse pressure and a bypass of 3.5, 5 or 7 bar, the QIH element withstands 210 bar and is therefore the one to specify whenever the bypass is blocked.
EPF4105QIHBT1MH202 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Parker EPF4105QIHBT1MH202 |
| Series / size | EPF iprotect high pressure filter, size 4 (replaces the 38P), element length 1 |
| Element | 05QIH: 5 micron Microglass III, high strength, collapse pressure 210 bar |
| Seals | Nitrile (code B) |
| Indicator | T1: electrical differential pressure indicator, NO/NC |
| Bypass / indicator setting | M with option 2: no bypass, 5 bar indicator setting |
| Ports | H20: SAE flange 1-1/4 inch, 6000M |
| Maximum operating pressure | 420 bar for size 4; housing pulse-fatigue tested to 10^6 pulses at 0 to 414 bar |
| Flow | 0 to 230 l/min per product page (length 1) |
| Operating temperature (nitrile) | −30 to +100 °C |
| Materials | Head: cast iron (GSI); bowl: steel |
| Fluids | Mineral oils to DIN 51524 HLP/HLPD, vegetable oils, 60/40 water glycols, non-aggressive synthetic oils |
| Replacement element | 944506Q (EPF high strength size 4 L1, 5 micron) |
| Weight | 15.8 kg (length 1) |
The iprotect design in the EPF4105QIHBT1MH202
The patented iprotect element lets the bypass valve and the metal core remain in the bowl as re-usable parts, so there are no loose parts to lose or forget when the element is changed. The element stays in the bowl when it is unscrewed from the head, which, according to the catalogue, can save more than 500 mm of service space compared with traditional high pressure filters. Filtration is from out to in and the core sits on the clean side. The catalogue lists reduced disposal weight, a shorter service time and a lower waste volume as benefits. With a blocked bypass, as on this part, the bypass function is not used, but the same element and bowl design apply.
The housing is a cast iron head with a steel bowl. It has been pulse-fatigue tested for one million cycles from 0 to 414 bar, and the catalogue gives 420 bar maximum allowable operating pressure for size 4.
Electrical indicator T1 and the 5 bar setting
The T1 indicator is a differential-pressure switch with normally open and normally closed contacts, which signals to the controller that the element is loaded. In the catalogue the T1 indicator has a 5 bar setting. Because the filter has no bypass, the signal is important: a clogged element raises the pressure drop continuously and, at some point, can starve the system or increase pump load. Wire the indicator into the machine alarm so that it triggers a service request before the pressure drop reaches the element limit. The family offers visual (M3) and electronic 4 LED PNP indicators (F1 normally open, F3 normally closed) as alternatives.
Sizing and related parts for EPF4105QIHBT1MH202
The product page lists a flow range of 0 to 230 l/min for this length 1 configuration, while the catalogue quotes a nominal flow above 320 l/min for size 4 in total. The catalogue states the recommended initial pressure drop at 1.2 bar for 3.5 bar bypass and 2.3 bar for 7 bar bypass, and estimates pressure drop at other viscosities by adding the housing drop and the element drop scaled by working viscosity over 30 cSt. The matching element is 944506Q. Other EPF4 length 1 high-strength elements are 944505Q (2 micron), 944507Q (10 micron) and 944508Q (20 micron). The catalogue standard part EPF4205QIBPMG201 is the length 2 version with threaded G1-1/4 ports and a 7 bar bypass. The same product family covers sizes 1 to 5, from 40 l/min to 700 l/min.
Selection and ordering checklist for EPF4105QIHBT1MH202
- System pressure below 420 bar and surges below the pulse-fatigue limit.
- Cleanliness target and micron rating; 2, 5, 10 or 20 micron are available.
- Whether a blocked bypass is acceptable; if so, high-strength elements are required.
- Indicator type and the controller input.
- Port type: G thread, SAE flange or manifold.
- Fluid compatibility with nitrile seals, or fluoroelastomer for hotter or special fluids.
Installation and servicing of the EPF4105QIHBT1MH202
Mount the filter vertically with room below the bowl. Follow the bowl torque on the catalogue drawing for the size 4 when reassembling. To service, drain the bowl through the plugged drain port, unscrew the bowl with the element inside, pull the old element out, drop the new element in and screw the bowl back. Order the replacement element with the Q suffix, as listed for this size, and do not mix element types. After the first fill, check the indicator, take an oil sample and log the pressure drop for later comparison.
Applications in Oman and the GCC
The catalogue lists mobile and industrial working hydraulics, control systems and servo controls as typical uses, and the product page names deck and mobile cranes, hydraulic presses, marine steering units, power packs, drilling equipment, industrial power units and wind turbines. In Oman these translate to heavy lifting and port equipment, marine hydraulics, drilling and workover, and industrial hydraulic power units. Heat, sand and humidity make an unbypassed filter with an alarm contact a practical choice for critical valves.
Information to send with an RFQ for EPF4105QIHBT1MH202
- Part number EPF4105QIHBT1MH202 and quantity, with spare elements.
- Working pressure, flow and fluid.
- Cleanliness target.
- Indicator wiring requirements.
- Delivery destination.
Documents and quotation
The Parker EPF iprotect catalogue with the ordering information, specifications and element table is attached on this page.
Seven Star LLC supplies Parker hydraulic filtration products in Oman and the GCC. Send the part number EPF4105QIHBT1MH202 with your quantity and we will confirm availability and quote.
Datasheets & Documents
- Catalog Parker EPF iprotect Filter Catalogue Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.
Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.
Parker company profile
| Founded | 1917, Cleveland, Ohio, USA, by Arthur L. Parker |
|---|---|
| Headquarters | Cleveland area, Ohio, USA |
| Ownership | Public company, New York Stock Exchange (PH), listed since 1964 |
| First product | Pneumatic brake system for trucks and buses |
| Product families | Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings |
Milestones
- 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
- 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
- 1957: Parker acquires Hannifin and becomes Parker Hannifin.
- 1964: The shares are listed on the New York Stock Exchange.
Parker product lines listed here
Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.
Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.
Where Parker components are used
Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.
Parker products we list
Ordering Parker parts: what we need
Parker part numbers are long and every character counts. Please send:
- Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
- Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
- Filter elements: element number and the housing model it fits
A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.
Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.
Browse Parker products by category: Solenoid Valve, Filtration Elements, Pumps.
FAQ
Questions about the Parker EPF4105QIHBT1MH202 iprotect High Pressure
Answers from our engineering team on installation, compatibility and integration.
01Does the EPF4105QIHBT1MH202 have a bypass valve?
No. The option 2 and the M code with no bypass mean the bypass is blocked, so a high-strength QIH element with 210 bar collapse pressure is used.
02What does T1 mean in the part number?
T1 is the electrical differential-pressure indicator with NO/NC contacts. Visual M3 and electronic F1 and F3 indicators are separate codes in the same table.
03Which element fits the EPF4105QIHBT1MH202?
The catalogue lists EPF High Strength Size 4 length 1, 5 micron, as 944506Q. Use the high-strength type whenever the bypass is blocked.
04What pressure rating does the EPF4 have?
The catalogue gives 420 bar maximum allowable operating pressure for size 4, with the housing pulse-fatigue tested to one million pulses from 0 to 414 bar.
05What temperature range applies with nitrile seals?
The catalogue states minus 30 to plus 100 degrees Celsius for nitrile seals and minus 20 to plus 120 degrees Celsius for fluoroelastomer.


















Reviews
There are no reviews yet.