Eaton ZB32-24 Thermal Overload Relay 16-24 A
Description
Eaton ZB32-24 thermal overload relay, 16 – 24 A
The Eaton ZB32-24 (catalog number 278453) is a three-pole thermal overload relay from the Moeller ZB range with an adjustable setting range of 16 to 24 A. It protects motors with a full-load current between 16 and 24 A against overload and phase failure, and it is designed for direct mounting on suitable DILM contactors. It has class 10 A tripping, one N/O and one N/C auxiliary contact, manual or automatic reset and a test/off button. Seven Star LLC supplies the ZB32-24 in Oman and the GCC.
The ZB32 frame is the mid-size frame of the ZB family and is intended for mid-size DILM contactors. The ZB32-24 covers 16 to 24 A, a band that includes many pump and compressor motors in the 7.5 kW to 11 kW class at 400 V.
How to read the model code ZB32-24
ZB is the series of thermal overload relays, the first number is the frame size (32) and the second number is the upper end of the setting range in amperes, here 24 A. The lower end of the range is given on the sheet as 16 A. The relay is set to the motor nameplate current on the dial; it does not contain a separate part number for coil voltage or terminal type, which makes the model code short and simple.
ZB32-24 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Eaton ZB32-24 (catalog number 278453) |
| Series / type | Eaton Moeller ZB thermal overload relay, frame ZB32 |
| Current setting range | 16 – 24 A |
| Trip class | Class 10 A (IEC 60947-4-1) |
| Auxiliary contacts | 1 N/O + 1 N/C |
| Reset | Manual / automatic, selectable by push-button |
| Functions | Test/off button, trip-free release, phase-failure sensitivity (IEC/EN 60947, VDE 0660 Part 102) |
| Rated operational voltage Ue / voltage rating, max | 690 V / 600 V AC |
| Rated impulse withstand voltage Uimp | 6000 V AC (4000 V for auxiliary and control circuits) |
| Auxiliary contact rating | AC-15: 1.5 A at 120–240 V, 0.9 A at 380–415 V; DC-13: 0.9 A at 24 V, 0.75 A at 60 V, 0.4 A at 110 V, 0.2 A at 220–230 V |
| Back-up fuse, type 1 coordination (100 kA, 690 V) | 125 A gG/gL |
| Back-up fuse, type 2 coordination (100 kA, 690 V) | 50 A gG/gL |
| Back-up fuse for auxiliary circuit | max. 6 A gG/gL |
| Temperature compensation | Continuous, residual error ≤ 0.25 %/K above 40 °C |
| Ambient temperature, open / enclosed | -25 to 55 °C / -25 to 40 °C |
| Heat dissipation, total / per pole | 6 W / 2 W |
| Main terminals, flexible with ferrule / stripping length | 2 x (1 – 4) mm² / 10 mm |
| Degree of protection / pollution degree | IP00 / 3 |
| Mounting | Direct mounting on the contactor |
| Dimensions (depth x height x width) | 96 x 67 x 45 mm |
| Weight | 0.145 kg |
All data above follows the manufacturer specification sheet for catalog number 278453. The sheet also lists UL and CSA short-circuit ratings and pilot-duty ratings for the auxiliary contacts.
How the ZB32-24 protects the motor
A thermal overload relay measures motor current through bimetal strips heated by the current itself. When the current is above the set value for long enough, the strips bend and release the tripping mechanism, which opens the N/C contact (95-96) in the contactor coil circuit and closes the N/O contact (97-98) for signalling. Class 10 A means that the relay trips within 10 seconds at 7.2 times the set current, the usual requirement for normal starting duty. The phase-failure sensitivity of the ZB32-24 shortens the trip time if one phase is lost, which protects the motor winding from the higher current in the two remaining phases.
Setting and testing the ZB32-24
- Set the dial to the full-load current on the motor nameplate, not to the contactor rating; the 16 to 24 A range covers motors up to roughly 24 A.
- Use the test/off button to check the contact action; check the sheet or the leaflet for the exact function of the button.
- Select manual reset for machines that must not restart unattended and automatic reset for unattended pumping stations where restart is acceptable.
Selection checklist for the ZB32-24
- Check that the motor nameplate current falls inside 16 to 24 A, ideally in the middle third of the range.
- Confirm the relay frame ZB32 matches the contactor you intend to use; the mounting is direct, so the pairing must be correct.
- Use a back-up fuse of 50 A gG/gL for type 2 coordination or 125 A gG/gL for type 1 coordination, as listed on the sheet.
- Wire the N/C contact into the coil circuit and the N/O contact into an alarm if needed.
- Check conductor size against the terminal capacity of 2 x (1 to 4) mmmm2 per main terminal.
Installation and maintenance of the ZB32-24
The relay measures 96 x 67 x 45 mm in depth, height and width and weighs 0.145 kg. Slide it onto the terminals of the contactor and tighten the connection screws; use a stripping length of 10 mm on the main cables. The relay should be fitted in an enclosure with ambient temperature up to 40 °C or in open air up to 55 °C. After a trip, find the cause (mechanical overload, voltage imbalance, phase loss or a worn bearing) before resetting. Check the setting dial and terminals at scheduled maintenance, and verify the trip function with the test button.
Applications of the ZB32-24 in Oman and the GCC
In Oman and the Gulf, overload relays protect pumps, fans, compressors and conveyors in oil and gas, water and desalination, power and building services. High ambient temperature is common in panels and outdoor enclosures, so the temperature compensation above 40 °C and the heat dissipation figure of 6 W per relay should be considered when you size the panel. Dust and humidity make periodic inspection of terminals worthwhile.
Eaton ZB overload relay family
| Model | Setting range | Frame |
|---|---|---|
| ZB12-10 | 6 – 10 A | ZB12 |
| ZB32-24 | 16 – 24 A | ZB32 |
| ZB65-10 | 6 – 10 A | ZB65 |
| ZB65-16 | 10 – 16 A | ZB65 |
| ZB65-24 | 16 – 24 A | ZB65 |
| ZB65-65 | 50 – 65 A | ZB65 |
The table lists the models covered by sibling pages. Other ranges of the ZB family exist; the exact current range is part of the model name, so quote the full ZB32-24 when you request a price.
Information to send with an RFQ for ZB32-24
- Exact model ZB32-24 (catalog number 278453) and the quantity, including spares.
- Motor nameplate current, voltage and starting duty.
- Contactor model that the relay will be fitted to.
- Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
- Any documents you need with the quotation, such as an installation leaflet or declaration of conformity.
Documents and quotation
The manufacturer specification sheet for ZB32-24 is attached on this page, so you can check the ratings, dimensions and approvals against your project before you order. Installation leaflets and declarations of conformity can be requested separately.
Seven Star LLC supplies Eaton industrial control products in Oman and the GCC. To request a quotation, send model ZB32-24, the quantity and your delivery location, and we will confirm availability and lead time for your order.
Other Models in the Eaton Zb Overload Relay Range
Seven Star LLC supplies models from the Eaton Zb Overload Relay range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Eaton ZB12-10 Thermal Overload Relay 6-10 A | Contactors & Overload Relays | View details |
| Eaton ZB32-24 Thermal Overload Relay 16-24 A | Contactors & Overload Relays | You are viewing this model |
| Eaton ZB65-10 Thermal Overload Relay 6-10 A | Contactors & Overload Relays | View details |
| Eaton ZB65-16 Thermal Overload Relay 10-16 A | Contactors & Overload Relays | View details |
| Eaton ZB65-24 Thermal Overload Relay 16-24 A | Contactors & Overload Relays | View details |
| Eaton ZB65-65 Thermal Overload Relay 50-65 A | Contactors & Overload Relays | View details |
Datasheets & Documents
- Datasheet Eaton ZB32-24 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.
Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.
Eaton company profile
| Founded | 1911, New York, USA, by Joseph O. Eaton |
|---|---|
| Early move | Cleveland, Ohio, 1914 |
| Headquarters | Dublin, Ireland, since the 2012 Cooper Industries acquisition |
| Listing | New York Stock Exchange (ETN) |
| Brands | Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC |
| Product families | FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling |
Milestones
- 1911: Joseph O. Eaton starts an axle business in New York.
- 1914: The business moves to Cleveland.
- 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.
Eaton circuit protection listed here
The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.
Where Eaton breakers and fuses are used
Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.
Eaton products we list
Ordering Eaton parts: what we need
Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.
Facts checked against Eaton's corporate history and investor materials, October 2026.
Browse Eaton products by category: Circuit Breaker.
FAQ
Questions about the Eaton ZB32-24 Thermal Overload Relay 16-24 A
Answers from our engineering team on installation, compatibility and integration.
01What is the setting range of the ZB32-24?
The relay is adjustable from 16 A to 24 A. Set it to the motor full-load current from the nameplate.
02What trip class does the ZB32-24 have?
It has trip class 10 A according to IEC 60947-4-1, with phase-failure sensitivity per IEC/EN 60947 and VDE 0660 Part 102.
03What auxiliary contacts does the ZB32-24 have?
One N/O and one N/C contact. The N/C contact is normally used in the contactor coil circuit and the N/O contact for an alarm signal.
04Which fuse protects the ZB32-24?
The sheet gives 125 A gG/gL for type 1 coordination and 50 A gG/gL for type 2 coordination, valid at 100 kA and 690 V.
05How large is the ZB32-24?
The sheet gives dimensions of 96 x 67 x 45 mm (depth x height x width) and a weight of 0.145 kg.