Brand:

Fluke 2AC VoltAlert Non-Contact Voltage Tester

Description

2AC VoltAlert non-contact voltage tester explained

The Fluke 2AC VoltAlert Non-Contact Voltage Tester (2AC) is a pocket-sized non-contact AC voltage detector. The tip glows red when voltage is present near an outlet, terminal strip or power cord, and the unit is always on with a battery check function. Seven Star LLC supplies 2AC in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The 2AC is the simplest tool for go/no-go testing. The table decodes its identifiers.

Element Value Meaning
2AC Model VoltAlert family member
90 V to 1000 V AC Detection range Operating range
CAT IV 1000 V Category Best-in-class rating per product page
Always on Power Battery check function

2AC technical specifications

Parameter Specification
Manufacturer / part number Fluke / 2AC
Operating principle Senses the steady-state electrostatic field of AC voltage through insulation
Operating voltage 90 V AC to 1000 V AC
Indication Red glow at the tip
Safety IEC 61010-1:2001, CAT IV 1000 V
Temperature (operating and storage) -10 °C to 50 °C
Humidity 0% to 95% (0 °C to 30 °C)
Altitude 2000 m
Battery life More than one year typical
Warranty Two years

Data are from the manufacturer product page for the Fluke 2AC.

How the Fluke 2AC VoltAlert Non-Contact Voltage Tester works

The tester senses the electrostatic field created by AC voltage. When the tip is close to a live conductor, even through insulation, the tip glows red. No contact with bare metal is needed, so it can be used on outlets, cords and terminal strips.

The battery check is optional and not a substitute for testing the unit on a known live source before and after use.

Key features

  • Always on
  • Battery check function
  • Pocket size
  • Two-year warranty
  • CAT IV 1000 V

Where 2AC fits and related Fluke models

The 2AC is for presence detection only; it does not give a value. For measured values use a multimeter or an open-fork tester. The 1AC II is a similar tester with different features.

Use it as a first check, not as proof of isolation.

Selection checklist for 2AC

Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.

  • Detection only from 90 V AC.
  • No DC detection.
  • Test before and after use on a live source.
  • Pocket clip.

Safe use, care and maintenance of 2AC

  • Check the instrument and its leads or tip before every use. Damaged insulation, a cracked housing or a weak battery are reasons to stop using the tester until it is repaired or replaced.
  • Follow the proving routine your site requires: test on a known live source, test the target, then test on the known source again.
  • Replace batteries when the display or indicator dims and do not mix old and new cells.
  • Keep the tester clean and dry and store it in its holster or case so the tip, probes or jaw are not damaged.
  • A tester is a safety tool. Do not use it outside its rated voltage and category.
  • Train every user on the limits of the tool. A tester that shows no voltage proves nothing until it has been proven on a known source, and a low battery or damaged probe can produce a false negative.
  • Keep a record of issue and return for tools held in a crib, and withdraw any unit that has been dropped hard, exposed to liquid or used beyond its rating until it has been checked.
  • In hot Gulf conditions avoid leaving the tester in direct sun on a vehicle dashboard, because heat shortens battery life and can damage the housing and display.

Typical applications of 2AC in Oman and the GCC

Electrical testers are part of every maintenance technician’s personal kit. In Oman they are used in substations, motor control centres, plant distribution boards and building services across oil and gas, utilities and industry. Safety rules at most major Omani operators require voltage to be proven absent before work begins, so a reliable, correctly rated tester is a basic item of personal equipment and is checked regularly. Choosing a model with the right category rating and the right way of detecting voltage reduces the temptation to improvise with unsuitable tools on live panels.

In Oman, electricians use VoltAlert pens as a quick screen at sockets, cables and panels at plants, camps and buildings before opening enclosures or starting work.

2AC compared with nearby models

Tool Indication Value shown Range
2AC Red tip glow No 90 to 1000 V AC
T5-1000 Display Yes Up to 1000 V
9040 Display Phase only 40 to 700 V

Non-contact detectors can miss shielded or low-field conductors.

Information to send with an RFQ for 2AC

To prepare an accurate quotation, please send:

  • Exact model 2AC and the quantity required.
  • Voltage range and category of the installations where it will be used.
  • Accessory needs such as a holster, spare probes or a proving unit.
  • Whether the tester is for individual technicians or a tool crib.
  • Delivery point in Oman or elsewhere in the GCC and the required date.

Storage, handling and spares for the Fluke 2AC

Store the Fluke 2AC in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.

  • Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
  • Use only leads and accessories rated for the same or a higher measurement category than the work you do.
  • Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
  • Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.

If your team uses several units of the Fluke 2AC, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.

Documents and quotation

Send the part number 2AC and we will confirm which manufacturer documents are available for this model.

For a quotation, send the part number 2AC, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.

Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 2AC VoltAlert Non-Contact Voltage Tester

Answers from our engineering team on installation, compatibility and integration.

01What does the Fluke 2AC detect?
Steady-state AC voltage from 90 V to 1000 V through insulation, with a red tip glow.
02Is it always on?
Yes, the tester is always on and includes a battery check function, which is optional and for convenience only.
03Can it replace a voltmeter?
No, it only indicates the presence of AC voltage and gives no measurement value; use a meter for measurements.
04What is its category rating?
It is rated CAT IV 1000 V and meets IEC 61010-1:2001 and UL 61010-1 requirements.
05How long does the battery last?
Typical battery life is more than one year, according to the manufacturer.