Brand: Fluke
Fluke T6-600 FieldSense Electrical Tester, Voltage and Current
Description
T6-600 FieldSense electrical tester explained
The Fluke T6-600 Electrical Tester (T6-600) is an open-fork electrical tester using FieldSense technology to measure AC voltage without test leads. It also reads true-RMS AC current to 200 A, AC/DC voltage to 600 V and resistance to 2000 Ω. Seven Star LLC supplies T6-600 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
FieldSense is the defining feature. The table decodes the identifiers.
| Element | Value | Meaning |
|---|---|---|
| T6 | Series | FieldSense open-fork testers |
| 600 | Voltage | 600 V maximum |
| FieldSense | Voltage method | Electric-field measurement through insulation |
| 17.8 mm | Jaw opening | Wires to AWG 4/0 |
T6-600 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Fluke / T6-600 |
| FieldSense AC voltage | 600 V, ±(3% + 3 counts), 45 Hz to 66 Hz |
| FieldSense AC current | 200.0 A, ±(3% + 3 counts) |
| Volts AC (leads) | 600 V, ±(1.5% + 2 counts) |
| Volts DC (leads) | 600 V, ±(1% + 2 counts) |
| Resistance | 2000 Ω, ±(1% + 2 counts) |
| Jaw opening | 17.8 mm |
| Dimensions / weight | 61.1 x 259.3 x 43.8 mm / 0.35 kg |
| Battery | Two AA, 360 hours; 200 with FieldSense |
| Safety | 600 V CAT III |
| Calibration cycle | 1 year |
Data are from the manufacturer product page and T6 datasheet.
How the Fluke T6-600 Electrical Tester works
FieldSense detects an electric field and compares it with a reference signal created by the tester, which displays the voltage value on the conductor without a metallic connection. Current is read using the magnetic field in the fork. No test leads are needed for these two functions.
The user should not touch the conductor under test, and should add a ground connection with the black probe when wearing insulating gloves or standing on an insulated ladder, otherwise 3% is added to the accuracy.
Key features
- Voltage without test leads
- True-RMS AC current to 200 A
- Backlit display and hold
- TPAK magnetic hanger compatible
- Resistance to 2000 Ω
Where T6-600 fits and related Fluke models
The T6-600 sits above the T5-1000 for convenience in tight boxes and below the T6-1000 in voltage range. Without leads it is quick but needs a proving routine; the PRV240 proving unit is made for T6 testers.
For multimeter functions use the 117.
Selection checklist for T6-600
Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.
- 600 V maximum.
- Accuracy impacted without ground reference.
- AWG 4/0 maximum wire.
- Proving unit recommended.
Safe use, care and maintenance of T6-600
- Check the instrument and its leads or tip before every use. Damaged insulation, a cracked housing or a weak battery are reasons to stop using the tester until it is repaired or replaced.
- Follow the proving routine your site requires: test on a known live source, test the target, then test on the known source again.
- Replace batteries when the display or indicator dims and do not mix old and new cells.
- Keep the tester clean and dry and store it in its holster or case so the tip, probes or jaw are not damaged.
- A tester is a safety tool. Do not use it outside its rated voltage and category.
- Train every user on the limits of the tool. A tester that shows no voltage proves nothing until it has been proven on a known source, and a low battery or damaged probe can produce a false negative.
- Keep a record of issue and return for tools held in a crib, and withdraw any unit that has been dropped hard, exposed to liquid or used beyond its rating until it has been checked.
- In hot Gulf conditions avoid leaving the tester in direct sun on a vehicle dashboard, because heat shortens battery life and can damage the housing and display.
Typical applications of T6-600 in Oman and the GCC
Electrical testers are part of every maintenance technician’s personal kit. In Oman they are used in substations, motor control centres, plant distribution boards and building services across oil and gas, utilities and industry. Safety rules at most major Omani operators require voltage to be proven absent before work begins, so a reliable, correctly rated tester is a basic item of personal equipment and is checked regularly. Choosing a model with the right category rating and the right way of detecting voltage reduces the temptation to improvise with unsuitable tools on live panels.
In Oman, electricians in crowded panels, junction boxes and switchgear compartments use the T6-600 to check voltage without hunting for metallic contact, saving time during maintenance and fault finding.
T6-600 compared with nearby models
| Model | Voltage | Current | Leads for voltage |
|---|---|---|---|
| T5-1000 | 1000 V | 100 A | Yes |
| T6-600 | 600 V | 200 A | No |
| 2AC | 90 to 1000 V AC | No | No |
The PRV240 proving unit has its own listing.
Information to send with an RFQ for T6-600
To prepare an accurate quotation, please send:
- Exact model T6-600 and the quantity required.
- Voltage range and category of the installations where it will be used.
- Accessory needs such as a holster, spare probes or a proving unit.
- Whether the tester is for individual technicians or a tool crib.
- Delivery point in Oman or elsewhere in the GCC and the required date.
Storage, handling and spares for the Fluke T6-600
Store the Fluke T6-600 in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.
- Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
- Use only leads and accessories rated for the same or a higher measurement category than the work you do.
- Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
- Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.
If your team uses several units of the Fluke T6-600, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.
Documents and quotation
A manufacturer datasheet for the Fluke T6-600 Electrical Tester is attached on this page so that you can check the full specification before ordering. Please review it against your site requirements.
For a quotation, send the part number T6-600, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.
Other Models in the Fluke T5 T6 Electrical Tester Range
Seven Star LLC supplies models from the Fluke T5 T6 Electrical Tester range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Fluke T5-1000 Voltage, Continuity and Current Tester | Electrical Testers & Multimeters | View details |
| Fluke T6-600 FieldSense Electrical Tester, Voltage and Current | Electrical Testers & Multimeters | You are viewing this model |
Datasheets & Documents
- Datasheet Fluke T6-600 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke T6-600 FieldSense Electrical Tester, Voltage
Answers from our engineering team on installation, compatibility and integration.
01What is FieldSense technology?
It measures AC voltage through an electric-field reference method so no metallic contact or test leads are needed.
02How large a conductor does the T6-600 take?
Wires up to AWG 4/0 (120 mm2) fit the 17.8 mm jaw opening.
03When should the ground probe be used?
When the user wears insulated gloves or stands on an insulated ladder, to keep FieldSense accuracy.
04What is the maximum current?
200 A AC true-RMS with 3% plus 3 counts accuracy.
05What batteries does it use?
Two AA cells; about 360 hours continuous, 200 hours using FieldSense.