Brand: Fluke
Fluke 28 II Rugged IP67 True-RMS Digital Multimeter
Description
28 II rugged true-RMS multimeter with thermometer explained
The Fluke 28 II Rugged True-RMS Digital Multimeter (28 II) is the top model of the Fluke 20 series. It is IP 67 rated, MSHA approved and drop-tested from 3 m, and adds true-RMS AC, a built-in thermometer, a low-pass filter for drives and a 20,000-count high-resolution mode. Seven Star LLC supplies 28 II in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
The 28 II extends the 27 II with several measurement functions; the table decodes the headline figures.
| Element | Value | Meaning |
|---|---|---|
| 28 II | Model | Top rugged model, second edition |
| IP 67 | Ingress protection | Waterproof and dustproof |
| True-RMS | AC measurement | Reads non-linear loads correctly |
| 8,000 V spike | Transient withstand | Load-switching spikes per manufacturer description |
28 II technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Fluke / 28 II |
| DC voltage | 0.1 mV to 1000 V, 0.05% + 1 |
| AC voltage | 0.1 mV to 1000 V, 0.7% + 4 |
| DC current | 0.1 µA to 10 A, 0.2% + 4 |
| AC current | 0.1 µA to 10 A, 1.0% + 2 |
| Temperature | -200 °C to +1090 °C |
| Capacitance | 1 nF to 9999 µF |
| Frequency | 0.5 Hz to 199.99 kHz |
| Peak capture | Transients as fast as 250 µs |
| Low-pass filter | Yes, for measurements on variable speed drives |
| Safety / IP | CAT IV 600 V, CAT III 1000 V / IP 67 |
| Battery | Three AA, 800 hours |
| Size / weight | 6.35 x 10.0 x 19.81 cm with holster / 698.5 g |
| Warranty | Limited lifetime |
Values come from the manufacturer product page for the Fluke 28 II.
How the Fluke 28 II Rugged True-RMS Digital Multimeter works
The 28 II is a sealed, drop-tested instrument with true-RMS measurement. A selectable low-pass filter attenuates the high-frequency switching content from variable speed drives so that the motor voltage reading is usable, and Peak Min/Max records transients as fast as 250 µs.
Its built-in thermometer reads K-type probes up to 1090 °C, and the high-resolution mode raises the display to 20,000 counts for finer readings. Relative mode removes test lead resistance from low-ohms work.
Key features
- True-RMS AC voltage and current
- Built-in thermometer, -200 °C to +1090 °C
- Low-pass filter for drive circuits
- High-resolution 20,000-count mode
- Backlit keypad and reversible holster
Where 28 II fits and related Fluke models
The 28 II is the more capable of the two rugged meters. If you need drive measurements, temperature or transient capture in a sealed meter, choose it over the 27 II. Equivalent non-rugged functions are in the 87V and 287.
Use the TL75 leads and AC175 clips supplied; optional magnetic hanger helps hands-free viewing.
Selection checklist for 28 II
Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.
- Need for true-RMS and drive measurement.
- Temperature range requirement (up to 1090 °C with probe).
- Exposure to water, dust and drops.
- Accessory set: leads, clips and thermocouple are included.
Safe use, care and maintenance of 28 II
- Before each shift, inspect the case, the holster and the test leads. Cracked insulation, exposed metal or a loose input jack means the leads should be replaced before the 28 II touches any live circuit.
- Confirm the meter on a known live source before and after a measurement that decides whether a circuit is dead. Never rely on a single reading when the result will be used to release a lock-out.
- Keep the input fuses to the specified type only. A blown fuse in the current inputs is the most common service event on a multimeter used on motor circuits, and a wrong fuse defeats the safety design of the Fluke 28 II Rugged True-RMS Digital Multimeter.
- Replace the battery when the low-battery symbol appears, because readings near the lower end of the range become unreliable on a weak cell. Remove the battery before long storage.
- Store the instrument clean and dry. In coastal Oman, wipe off salt film and condensation after outdoor use and avoid leaving it in a vehicle cabin in summer.
Typical applications of 28 II in Oman and the GCC
Handheld multimeters are carried in every plant. In Oman, oil and gas facilities, power stations, desalination plants and petrochemical sites rely on them for control-panel faults, motor circuits, instrument loops and routine electrical checks.
The 28 II suits maintenance teams working outdoors and in wet areas: pump stations, desalination plants, offshore support yards and mines. Its drive filter and thermometer make it a practical single instrument for motor fault finding on Omani oil and gas and water sites.
28 II compared with nearby models
| Model | True-RMS | Temperature | DC accuracy |
|---|---|---|---|
| 27 II | No | No | 0.1% + 1 |
| 28 II | Yes | -200 to 1090 °C | 0.05% + 1 |
| 287 | Yes | -200 to 1350 °C | 0.025% |
The 287 adds logging and graphing but is not IP 67 rated.
Information to send with an RFQ for 28 II
To prepare an accurate quotation, please send:
- Exact model 28 II and the quantity required.
- Whether the meter is for a lab, a workshop or field service, so the correct accessory set can be quoted.
- Required test lead type and any extra clips or probes.
- Temperature probe, case or magnetic hanger requirements.
- Whether calibration traceability paperwork is needed on delivery.
- Delivery point in Oman or elsewhere in the GCC and the required date.
Storage, handling and spares for the Fluke 28 II
Store the Fluke 28 II in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.
- Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
- Use only leads and accessories rated for the same or a higher measurement category than the work you do.
- Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
- Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.
If your team uses several units of the Fluke 28 II, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.
Documents and quotation
Send the part number 28 II and we will confirm which manufacturer documents are available for this model.
For a quotation, send the part number 28 II, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.
Other Models in the Fluke 20 Series Rugged Dmm Range
Seven Star LLC supplies models from the Fluke 20 Series Rugged Dmm range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Fluke 27 II Rugged IP67 Digital Multimeter | Electrical Testers & Multimeters | View details |
| Fluke 28 II Rugged IP67 True-RMS Digital Multimeter | Electrical Testers & Multimeters | You are viewing this model |
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke 28 II Rugged IP67 True-RMS Digital Multimeter
Answers from our engineering team on installation, compatibility and integration.
01What is the difference between 27 II and 28 II?
The 28 II adds true-RMS, a thermometer, a low-pass filter, peak capture and a 20,000-count mode; both share the IP 67 rugged body.
02Can the 28 II measure on variable speed drives?
Yes, it includes a low-pass filter intended for measurements on drive circuits.
03What temperature can the 28 II measure?
From -200 °C to +1090 °C with a thermocouple; the 80BK-A type-K leads are included.
04How fast can it capture peaks?
Peak Min/Max records transients as fast as 250 µs.
05What is its safety rating?
CAT IV 600 V and CAT III 1000 V, and it is stated to withstand 8,000 V spikes caused by load switching.