Schneider Electric A9D51210 iC60H RCBO 2P 10 A C 300 mA

Description

A9D51210: Acti9 iC60H RCBO 2P 10 A C curve 300 mA

The A9D51210 is a Schneider Electric Acti9 iC60 RCBO, a residual current breaker with overcurrent protection. The datasheet lists it as iC60H2 RCBO with 2P, 10 A at 50 °C, curve C, 300 mA earth-leakage sensitivity, type A earth-leakage protection and a 10000 A breaking capacity at 240 V AC. Seven Star LLC supplies the A9D51210 in Oman and the GCC as an independent supplier based in Muscat.

One device combines the overcurrent protection of a miniature circuit breaker with the residual current protection of an RCCB, so a single circuit gets both functions in a 36 mm body (4 modules of 9 mm).

Technical specifications of the A9D51210

Parameter Specification
Manufacturer / part number Schneider Electric / A9D51210
Range / product name Acti9 / Acti9 iC60 RCBO
Product type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60H2 RCBO
Poles description 2P
Protected poles 1
Rated current [In] 10 A at 50 °C
Curve code C
Earth-leakage sensitivity 300 mA
Earth-leakage protection class Type A
Earth-leakage protection time Instantaneous
Residual current tripping Voltage dependent
Earthing system TT / TN / IT
Trip unit Thermal-magnetic
Breaking capacity [Icn] 10000 A at 240 V AC 50/60 Hz (IEC 61009-1)
Service breaking capacity [Ics] 7500 A at 240 V AC 50/60 Hz
Rated operational voltage [Ue] 230/240 V AC 50/60 Hz
Limitation class 3
Rated insulation voltage [Ui] 400 V AC 50/60 Hz
Rated impulse withstand [Uimp] 4 kV
Impulse withstand current [Icw] 250 A, 8/20 µs
Suitability for isolation Yes
Network type / frequency AC / 50 Hz
Neutral position Left
Control / signalling Toggle; ON/OFF indication; contact position indicator
Mounting Clip-on, DIN rail
Width 36 mm (4 × 9 mm pitches)
Height / depth 110 mm / 77.5 mm
Net weight 332 g
Colour White
Terminals Top: 1–25 mm² rigid, 1–16 mm² flexible; bottom: 1–16 mm² rigid, 1–10 mm² flexible
Wire stripping / torque 13 mm bottom, 14 mm top / 2 N.m bottom, 3.5 N.m top
Locking Padlockable with 4 mm padlock
Mechanical / electrical durability 20000 / 5000 cycles
Standards IEC 61009-2-2, AS/NZS 61009.1, IEC 61009-1
Degree of protection IP20; IP40 in modular enclosure (IEC 60529)
Tropicalisation / humidity Level 2 / 95 % at 55 °C
Operating temperature -15 to 60 °C
Storage temperature -40 to 85 °C
Packing 1 piece, 298 g; carton of 27
Warranty 18 months

Earthing systems and wiring for the A9D51210

The datasheet lists the earthing system for this unit as TT / TN / IT. The three systems listed make it flexible across installations, but the protection chain and fault-loop calculation still have to be verified on site. The device has a left-hand neutral position and the connection diagram printed on the front must be followed. It is a two-pole device in a double-width body, with both conductors connected through the unit.

Selection checklist for the A9D51210

  • Circuit: 2P at 230/240 V AC, 10 A, protected cable sized for that rating.
  • Curve: C for general lighting, sockets and small motors.
  • Sensitivity: 300 mA against the protection goal.
  • Earthing: TT / TN / IT per the datasheet.
  • Fault level: compare 10000 A with the prospective short-circuit current.
  • Space: 4 modules, 36 mm.

Where the A9D51210 sits among iC60H RCBOs

The four iC60H RCBO references in this lane differ in pole description, rating, curve and sensitivity.

Part number Poles Rating Curve Sensitivity Earthing Width
A9D14840 1P + N 40 A C 30 mA TN 18 mm
A9D15840 1P + N 40 A C 100 mA TN 18 mm
A9D34820 1P + N 20 A B 30 mA TN 18 mm
A9D51210 (this page) 2P 10 A C 300 mA TT/TN/IT 36 mm

Installation and testing of the A9D51210

Isolate and prove dead, clip the A9D51210 onto the rail and connect the conductors following the diagram on its face, tightening to the torque values above. After energising, operate the test function on the device and confirm that it trips, then reset it.

A trip can come from overload, short circuit or leakage, so find the cause before closing the device again. Repeated residual trips usually point to damaged insulation or wet equipment on that circuit.

C curve and 10 A rating on the A9D51210

C-curve devices are designed to trip magnetically between roughly 5 and 10 times the rated current, the usual compromise for lighting, sockets and small motors. For 10 A that is about 50 to 100 A. This band is the general characteristic of the curve and is not a figure quoted in the datasheet, so check the manufacturer’s curve for the exact limits.

The breaking capacity of this unit is 10000 A at 240 V AC and the service breaking capacity Ics is 7500 A, with limitation class 3 in the datasheet. Compare the 10000 A value with the prospective short-circuit current at the board, and size the cable first from the load and installation method, then choose the 10 A device to protect it.

Typical uses of the A9D51210 in Oman and the GCC

RCBOs like this unit are typically specified where a single circuit needs both overcurrent and leakage protection, for example pump houses and kiosks, clinics and schools and site offices and camps. Heat, dust and coastal humidity are the main ageing factors, so keep the enclosure closed and test the residual function regularly. For critical loads follow the project specification over general advice.

Information to send with an RFQ for the A9D51210

  • Exact reference A9D51210 and the quantity needed.
  • Supply voltage, system type and earthing arrangement.
  • Load description and cable size for the circuit.
  • Prospective short-circuit current at the board, if known.
  • Other ratings or curves needed in the same order.
  • Delivery location and timeline.

Before ordering, check that the board enclosure, busbar arrangement and neighbouring devices leave enough room for heat to escape, since crowded boards in hot rooms run closer to their limits than the rated ambient suggests.

Keep a record of the installed ratings on the board schedule and note the supply voltage at commissioning, because later extensions and fault investigations depend on knowing exactly what protects each circuit.

Spare devices of the same rating, pole count, sensitivity and type are worth planning for sites that run continuously, since a like-for-like replacement keeps the original protection design intact after a trip or a fault.

If the board will be extended later, leave spare rail length and think about how added circuits change the leakage current seen by this device, which affects how close it runs to its trip threshold.

Documents and quotation

The Schneider Electric datasheet for the A9D51210 is attached on this page and holds the full specification summarised above. It is dated 8 Nov 2026 as printed on the manufacturer’s document.

Send us the reference A9D51210, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.

Other Models in the Se Acti9 Ic60h Rcbo Range

Seven Star LLC supplies models from the Se Acti9 Ic60h Rcbo range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric A9D34820 iC60H RCBO 1P + N 20 A B 30 mACircuit BreakersView details
Schneider Electric A9D51210 iC60H RCBO 2P 10 A C 300 mACircuit BreakersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric A9D51210 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric A9D51210 iC60H RCBO 2P 10 A C

Answers from our engineering team on installation, compatibility and integration.

01What is the A9D51210?
It is an Acti9 iC60 RCBO (iC60H2 RCBO) combining thermal-magnetic overcurrent protection with 300 mA type A earth-leakage protection, rated 10 A with a C curve.
02What breaking capacity does the A9D51210 have?
The datasheet lists 10000 A Icn at 240 V AC, a service breaking capacity Ics of 7500 A and limitation class 3.
03Which earthing systems does the A9D51210 list?
The datasheet lists TT, TN, IT. Confirm that the installation earthing system matches before ordering.
04What size and terminals does the A9D51210 have?
It is 36 mm wide, 110 mm high and 77.5 mm deep. Top terminals take 1 to 25 mm2 rigid and bottom terminals 1 to 16 mm2 rigid.
05What operating range is listed for the A9D51210?
Operation from -15 to 60 degrees C, storage from -40 to 85 degrees C, IP20 protection, 20000 mechanical and 5000 electrical cycles.