Schneider Electric A9D14806 iC60H RCBO 6 A 30 mA 1P+N

Description

A9D14806: Acti9 iC60H RCBO 6 A C curve 30 mA

The A9D14806 is a Schneider Electric Acti9 iC60H residual current breaker with overcurrent protection, an RCBO, in a single module that protects one phase conductor plus neutral. The datasheet lists a rated current of 6 A, a C curve, 30 mA earth-leakage sensitivity and a 230/240 V AC supply. Seven Star LLC supplies the A9D14806 in Oman and the GCC as an independent supplier in Muscat, mainly to panel builders and maintenance teams that need a like-for-like circuit protection device.

On the datasheet generated on 8 Nov 2026 the A9D14806 is not marked as discontinued. Confirm stock before the design relies on it.

How a combined RCBO differs from an MCB plus RCCB

An RCBO contains the overcurrent protection and the earth-leakage detection in one 18 mm wide module, so the A9D14806 protects its own circuit individually. A fault on one circuit therefore trips only that device, which is a clear advantage over an RCCB that supplies a group of circuits and drops them all together. The datasheet lists type A earth-leakage protection with instantaneous action, with voltage-dependent residual current tripping, which means that the earth-leakage function relies on the supply voltage to trip.

That detail matters for one reason: in a voltage-dependent device, loss of the neutral or a very low supply voltage may leave the earth-leakage function ineffective, so check how the project handles that case in its protection design.

Information to send with an RFQ for A9D14806

The points below let us confirm the part number against the datasheet and check stock in one reply.

  • Part number A9D14806 and quantity.
  • Rated current (6 A), curve and sensitivity (30 mA), from the existing device.
  • System voltage and earthing system.
  • Rail space available and the board temperature.
  • Whether a discontinued part is acceptable.
  • Delivery location.

A photo of the old device label makes a like-for-like check quick.

Where such devices are used in Oman and the GCC

Single module RCBOs like this unit are used in distribution boards for offices, workshops, camps, pump houses and utility rooms, and in small control panels on industrial sites. Protecting each circuit separately limits the outage when an earth fault happens, which is helpful where dust, humidity and heat raise leakage on outdoor circuits.

Short-circuit data for the A9D14806

The breaking capacity is stated as 10,000 A Icn at 240 V AC 50/60 Hz and the service breaking capacity Ics as 7,500 A, with energy limitation class 3. Rated insulation voltage is 400 V AC and impulse withstand is 4 kV. The device is suitable for isolation, shows its contact position and has ON/OFF indication on the front, and it is padlockable with a 4 mm padlock for lock-out during maintenance.

Surge current withstand is listed at 250 A for an 8/20 µs impulse, which is relevant where lightning-induced surges are possible. Mechanical durability is 20,000 cycles and electrical durability is 5,000 cycles.

Fitting the A9D14806 in a board and climate limits

The unit is clip-on to a DIN rail and occupies 2 pitches of 9 mm, which is 18 mm. It measures 110 mm high and 77.5 mm deep and weighs 205 g. The top screw clamp terminal accepts 1 to 25 mm² rigid or 1 to 16 mm² flexible, and the bottom 1 to 16 mm² rigid or 1 to 10 mm² flexible. The stripping length is 14 mm at the top and 13 mm at the bottom, with tightening torques of 3.5 N.m and 2 N.m. The datasheet states that comb busbar and distribution block compatibility is not provided, so wire it individually.

Test the earth-leakage function with the test button after installing this unit, and record the date. Neutral position is on the left, so watch the wiring orientation.

The datasheet lists IP20 for the device and IP40 in a modular enclosure, tropicalisation class 2, relative humidity of 95 % at 55 °C, an operating range of -15 to 60 °C and storage from -40 to 85 °C. The 60 °C upper limit is wider than for many residual current devices and helps in warm Gulf switchrooms, but the rated current is referenced to 50 °C, so a board running hotter should be checked carefully for the A9D14806.

The A9D14806 within the A9D iC60H group

Seven related devices share the C curve, the 18 mm width and the 10 kA breaking capacity, and they differ in current and sensitivity.

Part Rated current Sensitivity Poles Discontinued on
A9D10810 10 A 10 mA 1P + Ns not marked
A9D14806 6 A 30 mA 1P + N not marked
A9D14810 10 A 30 mA 1P + N not marked
A9D14816 16 A 30 mA 1P + N not marked
A9D14820 20 A 30 mA 1P + N not marked
A9D14825 25 A 30 mA 1P + N not marked
A9D14832 32 A 30 mA 1P + N not marked

Technical data of the A9D14806

Parameter Specification
Manufacturer / part number Schneider Electric / A9D14806
Range Acti9
Product name Acti9 iC60 RCBO
Product type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60H RCBO
Application Distribution
Poles 1P + N (1 protected pole)
Rated current [In] 6 A at 50 °C
Curve code C
Earth-leakage sensitivity 30 mA
Earth-leakage class Type A
Protection time delay Instantaneous
Trip unit technology Thermal-magnetic
Residual current tripping Voltage dependent
Earthing system TN
Breaking capacity 10000 A Icn at 240 V AC 50/60 Hz
Service breaking capacity [Ics] 7500 A at 240 V AC 50/60 Hz
Limitation class 3
Rated operational voltage [Ue] 230/240 V AC 50/60 Hz
Insulation voltage [Ui] 400 V AC 50/60 Hz
Impulse withstand [Uimp] 4 kV
Suitability for isolation Yes
Mounting Clip-on on DIN rail
Dimensions H / W / D 110 mm / 18 mm / 77.5 mm
9 mm pitches 2
Net weight 205 g
Mechanical / electrical durability 20,000 / 5,000 cycles
Padlocking Padlockable with padlock Ø 4 mm
Terminals Screw clamp terminal (top) 1–25 mm² rigid without cable end; Screw clamp terminal (top) 1–16 mm² flexible; Screw clamp terminal (bottom) 1–16 mm² rigid without cable end; Screw clamp terminal (bottom) 1–10 mm² flexible
Tightening torque Power circuit: 3.5 N.m top; Power circuit: 2 N.m bottom
Protection IP20; IP40 (modular enclosure)
Operating / storage temperature -15–60 °C / -40–85 °C
Relative humidity 95 % at 55 °C
Standards IEC 61009-2-2, IEC 61009-1

What the 6 A rating means for the A9D14806

At 6 A with 30 mA sensitivity this is the smallest rating in the 30 mA group. A 6 A rating suits low-power final circuits such as lighting groups and control power outlets, where a small breaker protects a thin cable.

The rated current is stated at 50 °C, which is a practical point for Gulf boards because it is the reference temperature for the thermal trip. The C curve is the common characteristic for mixed loads with moderate inrush, and the thermal-magnetic trip unit means overload and short-circuit are both handled by the device, while the earth-leakage part adds the residual current function.

Documents and quotation

A copy of the Schneider Electric datasheet for the A9D14806 is attached on this page for your technical file. It holds the electrical, mechanical and environmental values that are summarised above.

To request a quotation, send the part number and the quantity through the enquiry form and we will reply with availability and delivery terms. Seven Star LLC is an independent supplier and does not act for the manufacturer, so please compare the datasheet with your project requirements before you order.

Other Models in the Se Ic60h Rcbo Range

Seven Star LLC supplies models from the Se Ic60h Rcbo range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric A9D10810 iC60H RCBO 10 A 10 mA 1P+NCircuit BreakersView details
Schneider Electric A9D14806 iC60H RCBO 6 A 30 mA 1P+NCircuit BreakersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric A9D14806 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric A9D14806 iC60H RCBO 6 A 30 mA

Answers from our engineering team on installation, compatibility and integration.

01What are the main ratings of the A9D14806?
The datasheet lists 6 A at 50 °C, C curve, 30 mA earth-leakage sensitivity, type A and a breaking capacity of 10,000 A Icn.
02Is the A9D14806 an RCBO or an RCCB?
It is an RCBO, a residual current breaker with overcurrent protection, so it combines the overload and short-circuit trip with earth-leakage protection in one 18 mm module.
03How wide is the A9D14806 and how is it mounted?
It occupies two 9 mm pitches (18 mm), is clip-on for DIN rail mounting and measures 110 mm in height and 77.5 mm in depth.
04Is the A9D14806 discontinued?
The datasheet does not mark it as discontinued. Availability should be confirmed before ordering.
05Does Seven Star LLC supply the A9D14806 in Oman?
Yes. Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC. Send the part number and the quantity and we confirm availability and the documents we can provide.