Schneider Electric 16905 Acti9 RCCB-ID 30 mA Type AC
Description
16905: Acti9 RCCB-ID 30 mA type AC residual current breaker
The 16905 is a Schneider Electric Acti9 residual current circuit breaker, four pole, rated 125 A, with 30 mA earth-leakage sensitivity and a type AC characteristic. The datasheet names it a residual current circuit breaker ID Fi and lists the device short name as RCCB-ID. Seven Star LLC supplies the 16905 in Oman and the GCC as an independent supplier in Muscat, mostly for distribution boards that need a like-for-like replacement or an extension.
The datasheet, generated on 8 Nov 2026, marks the 16905 as discontinued on 27 Mar 2026. It carries no overcurrent release of its own, so it must be backed by suitable short-circuit protection upstream, and stock should be confirmed before ordering.
Information to send with an RFQ for 16905
The points below let us confirm the part number against the datasheet and check stock in one reply.
- Part number this unit and quantity.
- Required sensitivity and class, taken from the old device label.
- System voltage, earthing system and the upstream protection device.
- Board type, available rail space and temperature in the board.
- Whether the discontinued status is acceptable or a current replacement should be proposed.
- Delivery location.
A photo of the front of the existing device is the fastest way to confirm a match.
Technical data of the 16905
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / 16905 |
| Range | Acti9 |
| Product name | Acti9 RCCB-ID |
| Product type | Residual current circuit breaker (RCCB) |
| Poles | 4P |
| Neutral position | Left |
| Rated current [In] | 125 A |
| Network type | AC |
| Earth-leakage sensitivity | 30 mA |
| Earth-leakage protection class | Type AC |
| Protection time delay | Instantaneous |
| Tripping technology | Electromechanical |
| Rated breaking and making capacity [Im] | 1250 A, 400 V, IEC 61008 |
| Rated conditional short-circuit current [Inc] | 10 kA at 125 A |
| Rated operational voltage [Ue] | 400 V AC 50 Hz |
| Rated insulation voltage [Ui] | 440 V AC 50 Hz |
| Rated impulse withstand [Uimp] | 4 kV |
| Frequency | 50/60 Hz |
| Control type | Toggle |
| Mounting | 35 mm symmetrical DIN rail, fixed |
| 9 mm pitches | 8 |
| Height / width / depth | 86 mm / 72 mm / 76 mm |
| Net weight | 420 g |
| Colour | Grey |
| Mechanical / electrical durability | 5000 / 2000 cycles |
| Padlocking | Padlockable |
| Terminals | Tunnel type; 1.5–50 mm² rigid, 1.5–35 mm² flexible (one cable) |
| Tightening torque | 3 N.m |
| Protection | IP20; IP40 in a modular enclosure |
| Operating / storage temperature | -25–40 °C / -40–85 °C |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 2000 m |
| Standards | IEC 61008, IEC 60947-3, IEC 60947-1 |
Installation of the 16905
The device clips onto a 35 mm symmetrical DIN rail and occupies eight 9 mm pitches, which is 72 mm of rail. Its body is 86 mm high and 76 mm deep and its weight is 420 g. Tunnel terminals accept two flexible or rigid cables of 1.5 to 16 mm², or a single rigid cable up to 50 mm², or a single flexible cable up to 35 mm² (with or without ferrule). Strip 11 mm and tighten to 3 N.m. The connection pitch is 18 mm between phases, and the neutral position is on the left.
Check that all four poles are wired and that the downstream neutrals are not shared with other residual current devices. After fitting this unit, press the test button on the front, because the datasheet points to a regular test as part of maintenance, then record the result in the board log. The toggle is padlockable for isolation during work.
Short-circuit and load limits
An RCCB senses earth leakage but does not clear overloads or short circuits. The datasheet gives a rated making and breaking capacity of 1250 A at 400 V under IEC 61008 and a conditional short-circuit current Inc of 10 kA at 125 A, so an upstream breaker or fuse that limits the fault current to the stated level has to be fitted. Rated operational voltage is 400 V AC at 50 Hz, insulation voltage is 440 V AC, and impulse withstand is 4 kV.
Mechanical durability is 5,000 cycles and electrical durability is 2,000 cycles, which is adequate for a main device that is operated only for maintenance. The device is not intended for frequent switching of loads.
What the 30 mA and type AC ratings mean for the 16905
With 30 mA sensitivity this is the version normally associated with protection of people against indirect contact and as additional protection on socket and final circuits. It is fitted ahead of a group of outgoing circuits in a distribution board, so the rating of 125 A must be coordinated with the board incomer.
Within this group the 16905 is the most sensitive of the four, so it also has the highest chance of nuisance tripping on circuits with a lot of filtered electronics or long cable runs with high capacitance. The datasheet lists the protection time delay as instantaneous and the tripping technology as electromechanical, which means that tripping does not depend on an auxiliary voltage.
Comparing the 16905 with 16905, 16906, 16907 and 16924
These four RCCB-ID units share the 125 A rating, four poles and 72 mm width, and they differ in sensitivity and class.
| Part | Name | Sensitivity | Class | Discontinued on |
|---|---|---|---|---|
| 16905 | ID Fi | 30 mA | Type AC | 27 Mar 2026 |
| 16906 | ID Fi | 100 mA | Type AC | 17 Jan 2025 |
| 16907 | ID Fi | 300 mA | Type AC | 17 Jan 2025 |
| 16924 | ID | 30 mA | Type A | 25 Sept 2024 |
Where it fits in Oman and the GCC
Four pole RCCBs like this unit are used in main and sub-distribution boards in commercial buildings, workshops, water and desalination facilities and industrial plants. In Gulf installations the choice of sensitivity is usually dictated by the local wiring regulations and the client specification, so confirm the required value before you order a replacement.
Climate limits and enclosure
The datasheet lists IP20 for the device itself and IP40 when it is in a modular enclosure, pollution degree 3 and tropicalisation class 2 to IEC 61008, with relative humidity of 95 % at 55 °C and an operating altitude of 2000 m. The operating temperature range is -25 to 40 °C, with storage from -40 to 85 °C.
The upper operating limit of 40 °C is lower than many Gulf switchrooms reach in summer. Inside a closed board the temperature is higher than ambient, so check the board temperature rather than the room temperature, provide ventilation or air conditioning, and ask us to confirm the datasheet limits for the 16905 if the board runs hot.
Documents and quotation
A copy of the Schneider Electric datasheet for the 16905 is attached on this page for your technical file. It holds the electrical, mechanical and environmental values that are summarised above.
To request a quotation, send the part number and the quantity through the enquiry form and we will reply with availability and delivery terms. Seven Star LLC is an independent supplier and does not act for the manufacturer, so please compare the datasheet with your project requirements before you order.
Other Models in the Se Acti9 Rccb Id Range
Seven Star LLC supplies models from the Se Acti9 Rccb Id range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric 16905 Acti9 RCCB-ID 30 mA Type AC | Circuit Breakers | You are viewing this model |
| Schneider Electric 16906 Acti9 RCCB-ID 100 mA Type AC | Circuit Breakers | View details |
| Schneider Electric 16924 Acti9 RCCB-ID 30 mA Type A | Circuit Breakers | View details |
Datasheets & Documents
- Datasheet Schneider Electric 16905 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric 16905 Acti9 RCCB-ID 30 mA Type AC
Answers from our engineering team on installation, compatibility and integration.
01What sensitivity and class does the 16905 have?
The datasheet lists 30 mA earth-leakage sensitivity, an instantaneous protection time and type AC protection class.
02What is the rating of the 16905?
It is a four pole device rated 125 A at 400 V AC, 50/60 Hz, with Im of 1250 A and a conditional short-circuit current Inc of 10 kA at 125 A.
03Does the 16905 protect against overload?
No. It is a residual current breaker without an overcurrent release, so overload and short-circuit protection has to be provided upstream.
04Is the 16905 discontinued?
The datasheet marks it as discontinued on 27 Mar 2026. Availability should be confirmed before ordering.
05Does Seven Star LLC supply the 16905 in Oman?
Yes. Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC. Send the part number and the quantity and we confirm availability and the documents we can provide.