Schneider Electric MP500C SmartX Actuator for PIBCV 500N

Description

MP500C: SpaceLogic MP500C linear actuator for pressure independent control valves

The MP500C is a Schneider Electric SmartX linear actuator in the MP500C series, listed for pressure independent control valves. The datasheet gives 500 N of force, a brushless DC motor, a 24 V AC/DC supply and a 15 second stroke running time, with floating and proportional control. Seven Star LLC supplies the MP500C as an independent supplier in Oman and the GCC for HVAC contractors and building-automation teams working on chilled-water and heating-water terminals.

The reference has no ordering-code table in the datasheet, so the notes below stick to the stated specification. The datasheet title also mentions multi-signal control, which matches the floating input and the 0–10 V DC analogue input listed.

Power-loss behaviour and valve selection for the MP500C

The actuator is non-spring return. On loss of power the valve remains in its last position. If a safe position on supply failure is required by the system design, that has to be provided by valve choice or by the control strategy, because this actuator does not return the stem by itself.

The destination on the datasheet is pressure independent control valves, so confirm that the valve neck and stem connection are compatible with the MP500C before ordering; the datasheet does not list mounting adapters, and we do not assume them. Ask the valve supplier for the actuator compatibility table and send it with your RFQ.

How the MP500C positions a PIBCV valve

A pressure independent control valve holds the selected flow with an internal pressure-compensating element, so the actuator only has to set the flow position and does not have to fight changing differential pressure. A linear actuator pushes the valve stem in and out. The MP500C delivers 500 N and reaches full stroke in 15 seconds according to the datasheet.

Because the actuator calibrates its stroke automatically, it learns the travel of the valve on commissioning instead of relying on a fixed stroke setting. That reduces the chance of a mismatch between actuator travel and the valve it is bolted to, which is the classic cause of a valve that never fully closes.

Selection checklist

  • Valve: confirm the PIBCV model and stem force requirement of 500 N or less.
  • Signal: floating or 0–10 V DC from the controller.
  • Supply: 24 V AC/DC and 50 VA transformer capacity per actuator.
  • Feedback: 2–10 V DC position output wired to the controller if needed.
  • Environment: IP54, -10 to 50 °C, indoor installation.
  • Fail position: the actuator is non-spring return.

Control inputs and feedback

The datasheet lists two ways to command the actuator. A floating input signal moves the stem up or down by pulses, with a field-selectable travel time so the response can be matched to the controller. A 0–10 V DC analogue input positions the stem in proportion to the voltage, and the feedback output reports position as 2–10 V DC.

Choose one method per actuator and wire accordingly. For commissioning, check the controller signal at the terminal block with a meter before connecting this unit, because a mismatch between 0–10 V and 2–10 V ranges will show as a valve that does not fully open or close. The datasheet also lists two optional SPDT switches.

Installation and maintenance

Mount the actuator on the valve according to the valve supplier instructions, connect the terminal block, power the unit and run the automatic stroke calibration. Verify the full open and full closed positions against the feedback signal before the water system is balanced, because balancing results are only valid if the valve really reaches its end positions.

Keep spares of this unit for terminals that serve critical areas such as server rooms or laboratories. Where chilled-water risers are in humid shafts, check that condensation cannot run down the stem into the actuator housing and that the cable entry is sealed.

Technical specifications

Parameter Specification
Manufacturer / part number Schneider Electric / MP500C
Range SmartX Actuator
Series MP500C
Product type Electric linear actuator
Destination Pressure independent control valves
Motor type Brushless DC motor
Control signal Floating; proportional/modulating
Control type Automatic reset
Rated supply voltage 24 V AC/DC
Analogue input range 0–10 V DC
Feedback signal 2–10 V DC
Force 500 N (113 lbf)
Stroke running time 15 s
Stroke auto calibration Yes
Travel time option Field selectable floating input signal travel time
Switch function 2 SPDT (optional)
Power consumption 15 VA AC
Transformer rated power 50 VA
Power loss return Non-spring return
Leads and connections Terminal block; conduit connector holes
Electrical insulation class Class III
IP degree of protection IP54
Ambient temperature, operation -10–50 °C
Ambient temperature, storage -25–65 °C
Relative humidity 0–90 % RH, non-condensing

Supply, wiring and housing

The supply is 24 V AC/DC with 15 VA consumption and a 50 VA transformer rating, so size the supply for the highest total across all actuators on a common transformer. Connections are on a terminal block, and the housing has conduit connector holes for the cable run. The insulation class is Class III, meaning extra-low-voltage supply only.

The enclosure is rated IP54. The operating range is -10 to 50 °C with up to 90 % RH non-condensing, and storage -25 to 65 °C. That is narrower than the range of the damper actuators from the same maker, so the unit is intended for indoor plant rooms and risers, not unconditioned outdoor locations.

Information to send with an RFQ

  • Exact reference MP500C and quantity.
  • Valve make, model and size that the actuator must drive.
  • Controller output type: floating or 0–10 V DC.
  • Need for auxiliary switches or feedback.
  • Delivery location and project schedule.

Documents and quotation

The manufacturer datasheet for the MP500C is attached on this page and carries the specification summarised above. Check the revision date printed on it against your project documents before you rely on a figure.

Send us the reference MP500C, the quantity and the delivery location, and Seven Star LLC will reply to your request. We are an independent supplier based in Muscat and we confirm availability and lead time per enquiry.

Datasheets & Documents
  • PDF Datasheet Schneider Electric MP500C Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric MP500C SmartX Actuator for PIBCV

Answers from our engineering team on installation, compatibility and integration.

01What valves is the MP500C intended for?
The datasheet lists pressure independent control valves as the destination. Confirm the valve model and stem connection with the valve supplier before ordering.
02What force and speed does the MP500C offer?
It is listed with 500 N of force and a stroke running time of 15 seconds, driven by a brushless DC motor.
03What control signals does the MP500C accept?
It accepts a floating input and a 0-10 V DC analogue input, and provides a 2-10 V DC feedback signal. A field-selectable travel time is listed for the floating signal.
04Is the MP500C spring return?
No. It is non-spring return, so the valve stays in its last position when power is lost.
05What environment can the MP500C operate in?
The datasheet lists IP54, operation from -10 to 50 degrees C, storage from -25 to 65 degrees C and humidity up to 90 % RH non-condensing.