Schneider Electric SR3B261FU Zelio Modular Smart Relay 26 I/O
Description
SR3B261FU: modular Zelio Logic smart relay, 26 I/O, 100–240 V AC
The SR3B261FU is a Schneider Electric Zelio Logic modular smart relay. It carries 16 discrete inputs and 10 relay outputs (26 I/O) in a DIN-rail housing with a local display and a real-time clock, and it runs a ladder or function-block programme that replaces a small amount of hard-wired relay logic. SR3B261FU is powered from 100–240 V AC, so the first check before any order is that your control supply really matches. Seven Star LLC supplies the SR3B261FU in Oman and the GCC as an independent supplier based in Muscat.
Within the modular series this is the 26 I/O AC variant; the datasheet lists room for extension modules on the same bus, which is what separates the modular line from a closed compact relay. Programme size is 0–240 lines (ladder) or 0–500 lines (FBD).
Selection checklist for the SR3B261FU
- Confirm the control supply: 100–240 V AC; the other supply is a different suffix of the same series.
- Count inputs and outputs: 16 inputs and 10 relay outputs, plus any extension modules you intend to add.
- Check that the output group matches the load: 5 A for 2 outputs and 8 A for 8 outputs.
- This AC version has no analogue inputs; choose a DC reference if you need to read a level or temperature.
- You will need a PC cable to load the programme; the datasheet drawings refer to SR2USB01 and SR2BTC01 for this purpose.
Technical specifications of the SR3B261FU
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / SR3B261FU |
| Range | Zelio Logic |
| Product type | Modular smart relay |
| Inputs / outputs | 26 I/O: 16 discrete inputs, 10 relay outputs |
| Analogue inputs | None |
| Local display | Yes |
| Real-time clock | Yes |
| Programme size | 0–240 lines (ladder); 0–500 lines (FBD) |
| Cycle time | 6–90 ms |
| Programme backup | 10 years at 25 °C |
| Rated supply | 100–240 V AC (85–264 V, 50/60 Hz) |
| Supply current | 100 mA at 100 V and 50 mA at 240 V without extension; 80 mA at 100 V and 60 mA at 240 V with extensions |
| Power | 12 VA without extension, 17 VA with extensions |
| Relay output rating | 24–250 V AC / 5–30 V DC, normally open |
| Output thermal current | 5 A for 2 outputs and 8 A for 8 outputs |
| Net weight | 0.4 kg |
| Protection | IP20 terminal block, IP40 front panel |
| Operating temperature | −20 to 55 °C (−20 to 40 °C in a non-ventilated enclosure) |
| Storage temperature | −40 to 70 °C |
| Relative humidity | 95 % without condensation or dripping water |
| Operating altitude | 2000 m |
| Warranty | 18 months |
| Certifications listed | GOST, GL, CSA, UL, C-Tick |
Typical uses of the SR3B261FU in Oman and the GCC
With 26 I/O on 100–240 V AC, this unit fits small automation tasks where a PLC would be excessive: generator-room and utility auxiliaries, tank level and transfer control and lighting, signage and car-park sequences. Because extension modules can be added, it also suits skid and OEM panels that start small and grow. Ambient temperatures are high across the region and dust is fine, so cabinet ventilation and the derating note above deserve attention. Utilities, facilities contractors and OEM panel builders use units of this size mainly for standalone sequences, local backup logic and retrofits of ageing relay panels.
How the SR3B261FU compares with its Zelio Logic neighbours
The rows below are the nearest relatives of the SR3B261FU among the references we handle, each taken from its own datasheet. They share the screw-terminal housing style and the same relay-output ratings, but differ in supply, I/O count and in whether you buy a pack or a unit.
| Reference | Form | I/O | Supply | Inputs / outputs |
|---|---|---|---|---|
| SR3B101FU | Modular relay | 10 | 100–240 V AC | 6 / 4 |
| SR2PACKFU | Pack | 12 | 100–240 V AC | 8 / 4 |
| SR3B101BD | Modular relay | 10 | 24 V DC | 6 / 4 |
| SR2PACK2BD | Pack | 20 | 24 V DC | 12 / 8 |
| SR3PACKBD | Pack | 10 | 24 V DC | 6 / 4 |
Supply, programme and environmental limits
The rated supply is 100–240 V AC with limits of 85–264 V, 50/60 Hz. Quoted consumption is 100 mA at 100 V and 50 mA at 240 V without extension; 80 mA at 100 V and 60 mA at 240 V with extensions, and the power figure is 12 VA without extension, 17 VA with extensions. The unit tolerates terminal inversion without executing control instructions. The programme memory is checked on every power-up and is backed up for 10 years at 25 °C, with a cycle time of 6–90 ms. The unit has a real-time clock, so weekly schedules and timed events can live inside the programme; the datasheet gives a clock drift of 12 min/year over 0–55 °C or 6 s/month at 25 °C.
Operating temperature is −20 to 55 °C, limited to −20 to 40 °C in a non-ventilated enclosure; storage is −40 to 70 °C; humidity is up to 95 % without condensation. Protection is IP20 at the terminals and IP40 at the front, pollution degree 2, overvoltage category III, up to 2000 m. In Gulf plants that translates to a closed, ventilated cabinet, not an open junction box exposed to heat and dust.
Installation, wiring and maintenance of the SR3B261FU
Terminals accept 0.2–2.5 mm² solid or semi-solid conductors and 0.25–2.5 mm² flexible conductors with cable end, tightened to 0.5 N.m. The unit mounts on a 35 mm DIN rail, or can be screw-fixed with its retractable lugs, per the datasheet drawings. The datasheet connection diagrams call for a 1 A quick-blow fuse or circuit-breaker in the supply and inductive-load suppression where relay outputs drive coils.
Power up with field loads disconnected, check each input state on the display, then force each output before connecting equipment. Keep a copy of the programme with the project records so that a replacement can be loaded quickly; as a spare, the SR3B261FU should be stored dry within the −40 to 70 °C storage range. Periodic inspection should cover terminal tightness, cabinet temperature and dust on ventilation openings.
Inputs and outputs of the SR3B261FU
The 16 discrete inputs of the SR3B261FU are mains-voltage inputs rated 100–240 V AC, each drawing about 0.6 mA. The datasheet guarantees state 1 at 79 V or more and state 0 at 40 V or less, quotes an input impedance of 350 kΩ and lists frequency bands of 47–53 Hz and 57–63 Hz, which confirms that these inputs are intended for 50/60 Hz signals and cannot be driven from DC sensors. With long field cables the capacitive leakage can keep an AC input partly on, so the 40 V state-0 limit is the figure to compare with your wiring.
The 10 outputs are relay outputs with normally open contacts, suitable for 24–250 V AC or 5–30 V DC. Thermal current is 5 A for 2 outputs and 8 A for 8 outputs. The datasheet quotes an electrical life of 500,000 cycles in AC-12 at 230 V / 1.5 A, AC-15 at 230 V / 0.9 A, DC-12 at 24 V / 1.5 A and DC-13 at 24 V / 0.6 A, a minimum switching capacity of 10 mA at 12 V, a mechanical life of 10 million cycles, and a response time of 10 ms on and 5 ms off. Operating rate is 10 Hz without load but only 0.1 Hz at rated current, so these relays suit contactor coils and signalling duties rather than rapid cycling. With ten relays in one body, outputs can be split between a motor-starter group and a low-voltage signalling group, but remember the two different thermal-current classes listed above.
Information to send with an RFQ for the SR3B261FU
- Exact reference SR3B261FU and quantity.
- Control supply voltage and frequency on site.
- Load types on the outputs and whether surge suppression is fitted.
- Any accessories required in the same order, such as extension modules or a programming cable.
- Delivery location and project deadline.
Documents and quotation
The manufacturer datasheet for the SR3B261FU is attached on this page and lists the full specification summarised above, including dimension drawings and connection diagrams. Check the revision date against your project requirements.
Send us the reference SR3B261FU, the quantity and the delivery location and Seven Star LLC will reply to your RFQ. We supply as an independent supplier based in Muscat.
Other Models in the Se Zelio Sr Range
Seven Star LLC supplies models from the Se Zelio Sr range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric SR2PACK2BD Zelio Discovery Pack 20 I/O | Logic Controllers | View details |
| Schneider Electric SR2PACKFU Zelio Discovery Pack 12 I/O | Logic Controllers | View details |
| Schneider Electric SR3B101BD Zelio Modular Smart Relay 10 I/O | Logic Controllers | View details |
| Schneider Electric SR3B101FU Zelio Modular Smart Relay 10 I/O | Logic Controllers | View details |
| Schneider Electric SR3B261FU Zelio Modular Smart Relay 26 I/O | Logic Controllers | You are viewing this model |
| Schneider Electric SR3PACKBD Zelio Discovery Pack 10 I/O | Logic Controllers | View details |
Datasheets & Documents
- Datasheet Schneider Electric SR3B261FU Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric SR3B261FU Zelio Modular Smart
Answers from our engineering team on installation, compatibility and integration.
01What supply does the SR3B261FU need?
The datasheet lists a rated supply of 100-240 V AC with limits of 85-264 V, 50/60 Hz. Match it to your control supply before ordering, because the other supply is a different reference.
02How many inputs and outputs does the SR3B261FU have?
It offers 26 I/O: 16 discrete inputs and 10 relay outputs with normally open contacts. It has no analogue inputs.
03What are the output ratings of the SR3B261FU?
Relay outputs for 24-250 V AC or 5-30 V DC, thermal current 5 A for 2 outputs and 8 A for 8 outputs. Electrical life is 500,000 cycles at 230 V / 1.5 A in AC-12.
04Can the SR3B261FU be extended?
The datasheet lists consumption figures both without and with extensions, and its connection diagrams show extension modules on the same supply type, so the unit is designed to take them. Check module compatibility before ordering.
05What temperature range does the SR3B261FU allow?
Operation from -20 to 55 degC (-20 to 40 degC in a non-ventilated enclosure) and storage from -40 to 70 degC, with front protection IP40 and terminals IP20.