Schneider Electric LTMR08MFM TeSys T Motor Controller 0.4-8 A

Description

Availability status of the LTMR08MFM

The datasheet for the LTMR08MFM carries three notices: “Discontinued on: 28 Oct 2026”, “Discontinued – Service only” and “To be end-of-service on: 31 Jan 2027”. This page therefore describes a discontinued product. Support ends on the date given, and Seven Star LLC can only confirm what is actually available when you send the enquiry.

For a plant that already runs this controller the practical meaning is simple: spares and service support are time-limited. If you are planning a new installation, ask about a current replacement in the TeSys T range before committing. If you are keeping an existing panel alive, buy the spares you need while they can still be found, and record the reference and firmware you have.

What the LTMR08MFM is and what it controls

The LTMR08MFM is a Schneider Electric TeSys T motor controller, listed in its datasheet as: Motor Management, TeSys T, motor controller, Modbus, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240 VAC. It is the central unit of a motor management system: it measures the motor current, applies protection functions, records events and speaks Modbus to a PLC or a supervisory system. Seven Star LLC supplies the LTMR08MFM in Oman and the GCC as an independent supplier in Muscat.

Reading the reference: LTMR is the device short name and compatibility code given in the datasheet, and the title supplies the rest: Modbus, six logic inputs, three outputs, the current window and the 100 to 240 V AC supply. The 0.4 to 8 A measurement window places this controller on small and medium three-phase motors: dosing and transfer pumps, small fans and blowers, light conveyors and similar drives where a full TeSys T function set is wanted on a modest current.

Technical specifications of the LTMR08MFM

Parameter Specification
Manufacturer / part number Schneider Electric / LTMR08MFM
Description Motor Management, TeSys T, motor controller, Modbus, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240 VAC
Range / product name TeSys / TeSys T
Device short name LTMR
Type Motor controller
Device application Equipment monitoring and control
Measurement current 0.4 to 8 A
Rated supply voltage [Us] 100…240 V AC 50/60 Hz
Supply voltage limits 93.5 to 264 V AC
Communication protocol Modbus, RS 485 2-wire, addresses 1 to 247, 1.2 to 19.2 kbit/s; RJ45 and terminal block
Logic inputs 6; 3.1 mA at 100 V, 7.5 mA at 240 V
Outputs 1 NO + 1 NC fault signal; 3 NO
Short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1
Associated fuses 4 A gG for output; 0.5 A gG for control circuit
Width x height x depth 91 mm x 61 mm x 122.5 mm
Net weight 0.53 kg
IP degree of protection IP20
Ambient temperature, operation / storage -20 to 60 °C / -40 to 80 °C

What the LTMR08MFM protects against and records

The datasheet lists these protection types for the LTMR08MFM: earth-leakage protection, load fluctuation, locked rotor, overload, overload (long time), phase failure, phase unbalance, power factor variation, reverse polarity protection, thermal overload protection, thermal protection. Thermal overload, locked rotor, phase failure and phase unbalance are the classic motor-saving functions; earth-leakage and power-factor variation take the controller beyond what a thermal relay can see.

For maintenance staff the diagnostic list is as valuable as the protection list. The controller records event recording. A trip history with context information turns a nuisance trip into something that can be explained, for example a start that was too long or an imbalance that grew over several days.

Metering covers average current iavg, temperature, earth-fault current, imbalance current, phase current i1, i2, i3 rms. Accuracy figures in the datasheet include 1 % for current, 1 % for voltage from 100 to 830 V, 3 % for power factor and 5 % for active and reactive power.

Inputs, outputs and Modbus on the LTMR08MFM

There are six logic inputs. At 100 V each draws 3.1 mA and at 240 V 7.5 mA; the datasheet guarantees state 0 from 0 to 40 V (up to 15 mA for 25 ms) and state 1 from 79 to 264 V (at least 2 mA for 25 ms).

Outputs are one normally open plus one normally closed fault signal contact and three normally open contacts. Load current is 5 A at 250 V AC or 5 A at 30 V DC; the permissible power is 480 VA (AC-15, Ie 2 A, 500 000 cycles) and 30 W (DC-13, Ie 1.25 A, 500 000 cycles), with a maximum switching frequency of 2 Hz and an operating rate of 1800 cycles per hour. The datasheet names a 4 A gG fuse for the outputs and a 0.5 A gG fuse for the control circuit.

The communication port is Modbus on a 2-wire RS 485 interface with addresses 1 to 247 and a transmission rate from 1.2 to 19.2 kbit/s. Two connection styles are listed, an RJ45 socket and a terminal block with two shielded twisted pairs. The datasheet also lists a web server under web services.

Is the LTMR08MFM the right current window?

Against the LTMR27MFM it has the same housing, the same supply, the same six inputs and the same outputs; the only substantive difference in the datasheet is the current window. The 1.35 to 27 A model covers larger motors, while this one gives a finer low end down to 0.4 A.

Choose it when the motor full-load current is below about 8 A and you want the setting to sit comfortably inside the window; a motor that draws more than 8 A cannot be protected by this reference.

  • Motor nameplate current inside 0.4 to 8 A.
  • Control supply 100 to 240 V AC at 50/60 Hz (limits 93.5 to 264 V AC).
  • Modbus master available, or a plan to use the web server for diagnostics.
  • Output contacts sized for the contactor coil within the 2 A AC-15 figure.
  • Status accepted: this reference is discontinued.

Environment, standards and approvals for the LTMR08MFM

The LTMR08MFM is rated for an ambient of -20 to 60 °C in operation and -40 to 80 °C in storage, IP20, with operation up to 2000 m without derating. Pollution degree 3 and overvoltage category III are listed; surge and EMC immunity levels are given in the datasheet up to level 4 for fast transients on supply and relay outputs.

Standards named are IACS E10, IEC 60947-4-1, UL 508, EN 60947-4-1, CSA C22.2 No 14. Certifications listed for this exact reference are ABS, KERI, BV, EAC, CSA, GL, C-Tick, ATEX, UL, RMRoS, NOM, CCC, DNV, RINA, LROS (Lloyds register of shipping). Treat the list as the datasheet states it and confirm any project-specific approval, such as a marine class or a hazardous-area requirement, against the document before ordering.

Commissioning and service plan for the LTMR08MFM

Because the datasheet marks the LTMR08MFM as service-only, treat any unit you buy as a like-for-like spare for an existing system rather than the start of a new standard. Before fitting, note the Modbus address and the motor parameters configured in the controller so that a replacement can be set up identically.

If a replacement is needed on a project, send us the reference of the controller you are replacing, the expansion modules around it and the motor nameplate data. We will confirm what can be offered and say plainly if the exact reference is no longer obtainable.

Information to send with an RFQ for the LTMR08MFM

  • Full reference LTMR08MFM and the quantity
  • Whether it replaces an installed controller and the expansion modules in use
  • Motor nameplate current, voltage and power
  • Modbus master and addressing plan
  • Delivery location and timing

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it is the document to check against your own drawings.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Tesys T Ltmr Mfm Range

Seven Star LLC supplies models from the Se Tesys T Ltmr Mfm range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric LTMR08MFM TeSys T Motor Controller 0.4-8 AContactors & Overload RelaysYou are viewing this model
Schneider Electric LTMR27MFM TeSys T Motor Controller 1.35-27 AContactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric LTMR08MFM Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LTMR08MFM TeSys T Motor

Answers from our engineering team on installation, compatibility and integration.

01What motor current range does the LTMR08MFM measure?
The datasheet gives a measurement current of 0.4 to 8 A. The motor full-load current should sit inside this window.
02Is the LTMR08MFM still in production?
No. The datasheet shows a discontinuation date of 28 Oct 2026, the status 'Discontinued - Service only' and a planned end of service on 31 Jan 2027. Ask us what remains available before you plan around it.
03What supply voltage does the LTMR08MFM need?
The datasheet lists 100 to 240 V AC at 50/60 Hz with supply limits of 93.5 to 264 V AC and a current consumption of 8 to 62.8 mA.
04How does the LTMR08MFM communicate?
It has a Modbus port on a 2-wire RS 485 interface with addresses 1 to 247 and 1.2 to 19.2 kbit/s, available through an RJ45 socket or a terminal block. A web server is also listed.
05How many inputs and outputs does the LTMR08MFM have?
The datasheet lists six logic inputs and outputs made of one normally open plus one normally closed fault signal contact and three normally open contacts, rated 5 A at 250 V AC.