Technical specifications of the UB6000-F42-EP-IO-V15

Parameter Specification
Manufacturer / part number Pepperl+Fuchs UB6000-F42-EP-IO-V15
Sensing range 350 to 6000 mm; adjustment range 400 to 6000 mm; dead band 0 to 350 mm
Transducer Approx. 65 kHz; standard target 100 x 100 mm
Timing Response delay 312 ms; cycle time ≥ 78 ms; availability ≤ 300 ms
Switching output 1 push-pull, short-circuit and reverse-polarity protected; drop ≤ 2.5 V; switching frequency 2 Hz; default window mode, normally open, near point 400 mm
IO-Link Revision 1.1.4, Smart Sensor profile SSP 4.1.1; process data input 32 bit (16 bit measurement value, 8 bit scale, 2 bit switching signals); Vendor ID 1, Device ID 0x300707
Accuracy Repeat accuracy ≤ ± 0.1 % of full scale; temperature influence ≤ ± 0.75 % after 20 min
Supply 10 to 30 V DC; ≤ 85 mA no-load; ≤ 1200 mW
Setup TEACH-IN, selectable sound lobe width, synchronization; EEPROM 300,000 cycles
Indicators Green power; green flashing with short break for IO-Link mode; yellow object; red error, fast flashing for short-circuit or overtemperature
Ambient temperature -25 to 70 °C
Housing PC-GF10 and zinc die-cast, IP67, M12 plug, approx. 200 g; cULus Listed

How the UB6000-F42-EP-IO-V15 delivers data over IO-Link

The UB6000-F42-EP-IO-V15 sends a 16-bit distance value, an 8-bit scaling and two switching bits to the IO-Link master every cycle, so no analog card and no signal conversion are needed. Parameters such as measuring range, output mode, sound lobe width and filters can be written over the same cable, and sensors can be replaced with automatic parameter download from the master.

The push-pull output works in parallel as a standard switching signal in SIO mode when no IO-Link master is used. Its low switching frequency of 2 Hz reflects the long time of flight at 6 m.

System fit and related parts

Use the UB6000-F42-EP-IO-V15 for tank, silo and stockpile level measurement above 1 m, where long range is more valuable than speed. For short ranges up to 500 mm choose UB500-F42-I-V15; for compact M18 housings with IO-Link and analog output use the UC1000-18GS-IUEP-IO-V15. The UB2000-F42-U-V15 offers an intermediate range with a voltage output.

Selection and ordering checklist for the UB6000-F42-EP-IO-V15

  • Range up to 6000 mm and dead band of 350 mm.
  • IO-Link master port class and cable.
  • Output mode of the push-pull output.
  • Sound lobe width for the installation.
  • Response time of about 0.3 s is acceptable.
  • Mounting and protection from direct rain on the transducer.

Installation, commissioning and maintenance of the UB6000-F42-EP-IO-V15

Connect the 5-pin M12 cable to an IO-Link port, scan the sensor and load the IODD. Teach or set the switching points and check the process data against a tape measure. Avoid shared cable ducts with high-power cables where possible.

The datasheet states response delay of 312 ms, so do not use the sensor for fast control loops. For slow level control and inventory, this speed is normal.

Long-range measurement practice with the UB6000-F42-EP-IO-V15

At 6 m the ultrasonic pulse travels for about 35 ms each way, and the sensor needs several pulse cycles to filter the result. Dust, foam, steam and turbulent surfaces can weaken the echo, and temperature layers in tall vessels can bend the beam; use a narrower sound lobe and mount the sensor away from nozzles and ladders.

Keep the dead band free of fittings, because anything within 350 mm of the transducer cannot be distinguished from the target.

Typical applications in Oman and the GCC

In Oman and the GCC the UB6000-F42-EP-IO-V15 suits storage tanks of water and chemicals, sumps and open channels, hopper stock levels and vehicle detection, wherever up to 6 m range is needed and digital integration helps with asset monitoring.

Family comparison

Part Key difference
UB6000-F42-EP-IO-V15 (this part) 350 to 6000 mm, IO-Link, push-pull
UB500-F42-I-V15 30 to 500 mm, 4-20 mA
UB2000-F42-U-V15 Mid range with voltage output
UC1000-18GS-IUEP-IO-V15 M18, 70 to 1000 mm, IO-Link and analog

Information to send with an RFQ

  • Part number UB6000-F42-EP-IO-V15 and quantity
  • Range and dead band needed
  • IO-Link master type
  • Process medium and surface
  • Mounting arrangement
  • Delivery location

Site conditions in Oman for the UB6000-F42-EP-IO-V15

Field instruments in Oman are exposed to strong sun, high ambient temperature, wind-blown dust and, on coastal plants, salt in the air. When you specify the UB6000-F42-EP-IO-V15, check the ambient and process temperature limits, the enclosure rating and the wetted and housing materials against the actual installation point, and consider sunshades for transmitters mounted in direct sunlight. Cable entries should be sealed with suitable glands so that dust and moisture cannot enter the housing.

Calibration and verification planning matters as much as selection. Record the range, configuration and tag data of each UB6000-F42-EP-IO-V15 at commissioning, define a check interval that suits the criticality of the loop, and keep the certificates with the plant documentation so that audits and shutdown work can proceed without delay.

Documents and quotation

The manufacturer datasheet for UB6000-F42-EP-IO-V15 is attached on this page, so you can check wiring, approvals and dimensions before ordering. Send the exact part number, quantity and delivery location in Oman or the GCC and Seven Star LLC will reply with a quotation.

Seven Star LLC is an independent supplier in Muscat and is not the manufacturer; confirm availability, lead time and any project approval requirements in your RFQ.

Other Models in the Pf Ub F42 Range

Seven Star LLC supplies models from the Pf Ub F42 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pepperl+Fuchs UB500-F42-I-V15 Ultrasonic Sensor, 500 mmUltrasonic SensorsView details
Pepperl+Fuchs UB6000-F42-EP-IO-V15 Ultrasonic Sensor, 6 mUltrasonic SensorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Pepperl+Fuchs UB6000-F42-EP-IO-V15 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs UB6000-F42-EP-IO-V15 Ultrasonic

Answers from our engineering team on installation, compatibility and integration.

01What is the measuring range of the UB6000-F42-EP-IO-V15?
350 to 6000 mm sensing range, with an adjustment range of 400 to 6000 mm and a dead band of 0 to 350 mm.
02Which IO-Link version is used?
IO-Link revision 1.1.4 with Smart Sensor profile SSP 4.1.1 and a 32-bit process data input.
03What is the switching output type?
One push-pull output, short-circuit and reverse-polarity protected, with a switching frequency of 2 Hz.
04How quickly does it respond?
The response delay is 312 ms and the cycle time at least 78 ms.
05What are the environmental limits?
-25 to 70 °C ambient and IP67 protection.