A 15 kW ACS480-04 for 400 V machines

The 15 kW rating starts frame R4, the largest ACS480 housing. In ABB’s ratings table the matching type is the ACS480-04-033A-4: 15 kW typical motor power, 32 A nominal output, frame R4. It belongs to the all-compatible drive platform, so panels, PC tools and fieldbus adapters are shared with the ACS380 and ACS580 families.

Hardware included in the standard unit: an RIIO-01 module with digital, analog and relay I/O plus EIA-485, an embedded Modbus RTU fieldbus, a built-in brake chopper and an internal EMC filter for category C2. Other ratings are in AC drives and the general purpose range is introduced on the ABB ACS580 overview.

Technical specifications

Parameter Specification
Order type ACS480-04-033A-4
Family and mounting ACS480 general purpose, 04 = module
Mains voltage class Three-phase 400 V class, code 4
Frame R4
No-overload rating 15 kW, 32 A
Light duty 15 kW, 30.5 A
Heavy duty 11 kW, 25 A
Peak current 45 A
Mains current without and with choke 40.7 A / 32 A
IEC gG fuse 63 A, OFAF000H63
IEC gR fuse 100 A, 170M2700
MCB option S 203P-B 63
Losses, cooling air, noise 396 W / 150 m3/h / 69 dB(A)
Switching frequency derating (8 / 12 kHz) 0.65 / 0.49
IP20 height, width, depth 240 x 262 x 213 mm
Mass in IP20 5.6 kg

Ratings and overload of the ACS480-04-033A-4

The IEC ratings table gives nominal use 32 A / 15 kW, light duty 30.5 A / 15 kW and heavy duty 25 A / 11 kW, with a maximum current of 45 A. The input current is 40.7 A without a choke and 32 A with a choke. Take the motor nameplate current as the starting point, not the kilowatt figure alone.

Upstream protection: 63 A gG (OFAF000H63, I2t 20000 A2s) or 100 A gR (170M2700); a breaker option is S 203P-B 63. Heat loss is about 396 W (1351 BTU/h) and air flow 150 m3/h, with noise of 69 dB(A).

Switching frequency derating factors are 0.65 at 8 kHz and 0.49 at 12 kHz, with none at 4 kHz. Between +50 and +60 degrees C the current decreases by 1% for each extra degree, and above 1000 m altitude by 1% per 100 m.

Dimensions of frame R4: IP20 height 240 mm (back height 205 mm), width 262 mm, depth 213 mm, 5.6 kg. With the UL Type 1 kit the height becomes 391 mm and the weight 6.9 kg. Allow 75 mm free space above and below. The maximum motor cable is 100 m without EMC limits; for EMC compliance ABB lists 30 m for category C3 and 10 m for C2 with the internal filter, or 30 m for C1, C2 and C3 with the optional external filter.

How the code is built

An order starts with ACS480-04-033A-4: 04 means module, 033A is the rating and 4 the voltage class. Optional features are selected by plus codes such as L534 for BAPO-01 external 24 V DC, J429 for the ACS-AP-W Bluetooth panel, J425 for the ACS-AP-I panel and J424 for a blank panel cover. The base unit without panel and I/O module is ordered with +0J400+0L540.

The technical data chapter also lists an input frequency of 47 to 63 Hz, an output frequency of 0 to 500 Hz, switching frequencies of 2, 4, 8 or 12 kHz and a fundamental power factor of 0.98 at nominal load.

Documentation and quotation

Seven Star LLC can quote the ACS480-04-033A-4 from Muscat. Attach the motor nameplate and the supply voltage to your RFQ. The linked ABB hardware manual (3AXD50000047392, revision F) supplies the ratings, fuses, losses, derating and dimensions shown.

Please confirm the ordering code, panel and fieldbus options, and the site derating before you order.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.

ABB company profile

Formed 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50%
ASEA Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators
Brown, Boveri & Cie Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri
Headquarters Zurich, Switzerland; ABB Ltd became the group holding company in 1999
Ownership Public company listed on SIX Swiss Exchange and Nasdaq Stockholm
Brands in the group Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers
Product families Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots

Milestones

  • 1883: ASEA is founded in Västerås, Sweden.
  • 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
  • 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
  • 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
  • 2011 and 2017: Baldor Electric and B&R join ABB.
  • 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.

Choosing an ABB drive

ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.

Where ABB products are used

In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.

ABB products we list

Family Examples
AC drives ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module
Breakers, motor control and protection SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay
Flow measurement ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500
Pressure, temperature and level 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge
Analysers Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210
Control systems and actuators AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000

Ordering ABB products: what we need

Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.

Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.

Frequently Asked Questions

What are the ratings of the ACS480-04-033A-4?
ABB lists 32 A nominal for 15 kW, 30.5 A light duty for 15 kW and 25 A heavy duty for 11 kW, with a maximum current of 45 A.
Which fuse does the manual give for the ACS480-04-033A-4?
The manual lists 63 A gG fuses of type OFAF000H63, 100 A gR fuses of type 170M2700, or the circuit breaker S 203P-B 63.
How large and heavy is the ACS480-04-033A-4?
Frame R4 measures 240 mm high, 262 mm wide and 213 mm deep in IP20 and weighs 5.6 kg; with the UL Type 1 kit it weighs 6.9 kg.
Does the ACS480-04-033A-4 need derating at higher switching frequency?
Yes. ABB gives a derating factor of 0.65 at 8 kHz and 0.49 at 12 kHz; no derating is needed at 4 kHz.
What is included in the standard ACS480-04-033A-4 unit?
The standard unit has the ACS-AP-S assistant panel, the RIIO-01 I/O and EIA-485 module, an EMC category C2 filter, Safe Torque Off and a brake chopper in IP20 module form.