Allen-Bradley 1734-AENT POINT I/O EtherNet/IP Adapter

Description

The single-port network adapter for POINT I/O

The Allen-Bradley 1734-AENT is the series C EtherNet/IP adapter for POINT I/O. It sits at the head of a node, gives the modules a connection to an EtherNet/IP network and supplies the POINTBus backplane and field power bus. It has one Ethernet port, which distinguishes it from the dual-port 1734-AENTR that supports Device Level Ring.

Use it where the network is a star or linear topology and a controller such as a ControlLogix or CompactLogix reads the I/O. The installation sheet states that it controls and communicates with POINT I/O modules from an EtherNet/IP network.

Technical specifications

Parameter Specification
Manufacturer / family Allen-Bradley (Rockwell Automation) / POINT I/O
Catalog number 1734-AENT (1734-AENTK is the coated version), series C
Function EtherNet/IP communications adapter for POINT I/O modules
Expansion I/O capacity, max 63 modules
Connections Up to 5 rack-optimization / enhanced rack-optimization connections; 31 direct connections
POINTBus output current, max 5V DC at 1.0 A
Field power supply / output 10 to 28.8V DC at 10 A / 10 to 28.8V DC at 9 A
Power consumption / dissipation, max 10.4 W / 5.2 W at 28.8V DC
Isolation voltage 50V continuous, reinforced insulation between all circuits
Network connector Ethernet RJ45
Address setting Three-position thumbwheel switches (ships at 999, DHCP enabled), DHCP, or stored address
Dimensions (H x W x D), approx. 75.3 x 56.1 x 133.1 mm (2.96 x 2.21 x 5.24 in.)
Weight, approx. 255 g (0.56 lb)
Indicators 3 red/green status (module, network, POINTBus); 1 green network activity; 2 green power

Capacity and power

A node can contain up to 63 modules with up to five rack-optimized or enhanced rack-optimized connections and 31 direct connections. The adapter supplies 1.0 A of 5V DC to the backplane, and each module has a listed POINTBus current requirement, such as 75 mA for the common digital and analog modules and up to 220 mA for the thermocouple and RTD types. Add them up, and add 1734-EP24DC or 1734-EPAC supplies when the total exceeds 1.0 A.

The field power input accepts 10 to 28.8V DC and can supply up to 9 A to the field bus. Maximum power consumption is 10.4 W and dissipation is 5.2 W at 28.8V DC.

Setting the IP address and commissioning

The adapter ships with its thumbwheel switches at 999 and DHCP enabled. The address can be set with the switches, by a DHCP server such as a BootP/DHCP tool, or recovered from nonvolatile memory. If the switches are set to an invalid number, the adapter checks whether DHCP is enabled; when it is, it asks the server, otherwise it uses the stored address.

The chassis size must be configured before any I/O connections are made; the factory default is a one-module chassis. LED indicators show module, network and POINTBus status, network activity and the two power statuses. A steady red network indicator means a duplicate IP address was detected.

Documents and quotation

The sheet 1734-IN042 covers the adapter. For a quotation send the 1734-AENT reference, series, quantity, the controller and the module list of the node. Related hardware is listed in Industrial Communications and 1734-AENTR dual-port adapter.

How the 1734-AENT Works

The 1734-AENT acts as the gateway between an EtherNet/IP network and the POINT I/O modules mounted to its right. On the network side, a controller such as a ControlLogix or CompactLogix opens connections to the adapter and exchanges I/O data at the requested packet interval (RPI). On the backplane side, the adapter scans the modules over POINTBus, collects input data and distributes output data. A rack-optimized connection bundles the digital data of many modules into a single connection, which saves controller connections, while direct connections give each module its own connection and are normally used for analog and specialty modules.

The adapter also powers the node. It converts its 24V DC input into the 5V DC POINTBus supply for module electronics, and passes the 24V DC field power along the terminal bases to the I/O modules until a field potential distributor or expansion power supply starts a new power group.

Selection & Ordering Guide for the 1734-AENT

  • 1734-AENT – single-port EtherNet/IP adapter for star or linear networks.
  • 1734-AENTK – conformal-coated version.
  • 1734-AENTR – dual-port adapter with an embedded switch for Device Level Ring or linear topologies.
  • 1734-EP24DC – expansion power supply when the POINTBus current of the node exceeds the adapter’s 1.0 A.

When you request a quote, list the modules in the node so their POINTBus current can be added up, and mention the controller and its software version so that compatibility and the series letter can be checked. Our team can help confirm the correct ordering code.

Installation & Maintenance of the 1734-AENT

  • Mount the adapter at the left of the node on DIN rail, then add the terminal bases and modules to its right.
  • Set the IP address with the thumbwheels, by DHCP or from stored memory, and record it on the panel drawing.
  • Configure the chassis size in the controller project to match the actual number of modules before making I/O connections.
  • Use industrial shielded Ethernet cable and a managed switch, and keep network cables away from drive output and power wiring.
  • Back up the controller project, which holds the node configuration, so a replacement adapter can be set up quickly.
  • Check firmware revision against the controller requirements before replacing an adapter in an existing system.

Typical Applications in Oman & the GCC

The 1734-AENT is used to build distributed I/O nodes close to the process: remote panels on water pumping stations, skids and packages in oil and gas facilities, conveyor and packaging lines, and building management systems in large commercial projects. Placing the I/O near the field devices cuts long multicore cable runs back to the control room and replaces them with a single Ethernet cable.

Why Source from Seven Star LLC

Seven Star LLC is an independent supplier in Muscat. Seven Star LLC supplies Allen-Bradley POINT I/O adapters and modules across Oman and the GCC. Send the 1734-AENT catalog number, the quantity and the node module list and request a quote; our team can help confirm the correct ordering code.

Datasheets & Documents
  • PDF Installation Instructions Allen-Bradley POINT I/O 1734-AENT EtherNet/IP Adapter Installation Instructions (1734-IN042) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Allen-Bradley is the brand of Rockwell Automation for industrial control: ControlLogix and CompactLogix controllers, I/O systems, PanelView operator terminals, PowerFlex drives, motor control and industrial network equipment. The company began in Milwaukee in 1903, when Lynde Bradley and Dr. Stanton Allen formed the Compression Rheostat Company to make the motor speed controller Bradley had invented in 1901. It took the name Allen-Bradley in 1909 and was bought by Rockwell International in 1985. Since 2001 its owner has been Rockwell Automation, which is still headquartered in Milwaukee, Wisconsin.

Allen-Bradley company profile

Founded 1903, Milwaukee, Wisconsin, USA, as the Compression Rheostat Company
Founders Lynde Bradley (inventor of the compression rheostat, 1901) and Dr. Stanton Allen (investor); Harry Bradley joined in 1904
Name Allen-Bradley Company from 1909
Ownership Acquired by Rockwell International in 1985 for about USD 1.65 billion; a brand of Rockwell Automation (NYSE: ROK) since 2001
Headquarters Milwaukee, Wisconsin, USA
Product families Logix programmable automation controllers (ControlLogix, CompactLogix), legacy SLC 500 and MicroLogix PLCs, Micro800 controllers, POINT, FLEX and Compact I/O, PanelView HMIs, PowerFlex AC drives, contactors, motor starters and soft starters, safety components, Stratix Ethernet switches

Milestones

  • 1901: Lynde Bradley invents the compression rheostat to control the speed of electric motors.
  • 1903: The Compression Rheostat Company is formed in Milwaukee with an initial investment of USD 1,000.
  • 1904: Harry Bradley joins; a crane controller is shown at the St. Louis World's Fair.
  • 1909: The company is renamed Allen-Bradley.
  • 1985: Rockwell International acquires Allen-Bradley.
  • 2001: Rockwell Automation becomes the company's name; the Allen-Bradley brand marks 100 years in 2003.

Reading Allen-Bradley catalogue numbers

The first digits of an Allen-Bradley catalogue number identify the platform, which tells you what is compatible with what. 1756 is ControlLogix (chassis-based, used for large process and plant control), 1769 is CompactLogix 5370 with Compact I/O, 5069 is CompactLogix 5380 with Compact 5000 I/O, 1734 is POINT I/O, 1794 and 5094 are FLEX and FLEX 5000 distributed I/O, 1746 and 1747 belong to the older SLC 500 family, 1766 is MicroLogix 1400 and 2080 is Micro800. For drives, 25B is PowerFlex 525 and 22B is PowerFlex 40; in a code such as 25B-D010N114, "D" means 380–480 V, "010" is the output current rating, and N114 instead of N104 means the drive has an integrated EMC filter. Many plants in the region still run SLC 500 and older MicroLogix systems, which Rockwell has discontinued, so exact spares and migration to CompactLogix are both common requests.

Where Allen-Bradley products are used

In Oman and the GCC, Allen-Bradley controllers and drives run on oil and gas facilities, water treatment and pumping stations, cement, food and beverage and packaging plants, and on machines supplied by American OEMs. ControlLogix is often the platform for plant control systems, while PowerFlex drives are used on pumps, fans and conveyors.

Allen-Bradley products we list

Family Examples
ControlLogix 1756-L85E, 1756-EN2T, 1756-EN2TR, 1756-IF16, 1756-IB32, 1756-PA75, 1756-A10
CompactLogix and Micro controllers 5069-L320ER, 5069-L340ERM, 1769-L33ER, 1769-L16ER, MicroLogix 1400, Micro820, SLC 500 (1746)
Distributed I/O 1734-AENTR, 1734-IB8, 1734-IE2C, 1734-IB8S safety, 1794-AENTR, 5094-AENTR, 5069-IF8
Operator terminals PanelView Plus 7 10-inch, PanelView Plus 7 15-inch, PanelView 800, PanelView 5310
Drives, motor control and networking PowerFlex 525, PowerFlex 755, PowerFlex 4, 150-A180NBD SMC, Stratix 2000, 1783-NATR

Ordering Allen-Bradley products: what we need

Send the full catalogue number and the series letter from the label (for example 1756-EN2T Series D), because firmware and compatibility can change between series. For drives, add the motor power, voltage and filter option. For a discontinued SLC 500 or MicroLogix part, tell us whether you need the exact spare or a migration proposal.

Facts checked against Rockwell Automation's published company history, October 2026.

Frequently Asked Questions

Is 1734-AENT a dual-port adapter?
No. It has one RJ45 Ethernet port. The dual-port version is the 1734-AENTR.
How many modules can it support?
The sheet lists up to 63 modules, subject to the backplane current of 1.0 A and any expansion supplies.
How is the IP address set?
With the three-position thumbwheel switches, by a DHCP server, or from nonvolatile memory. The adapter ships with the switches at 999 and DHCP enabled.
How do I extend the backplane current?
Add 1734-EP24DC or 1734-EPAC expansion power supplies, as stated in the installation sheet.
What does a steady red network indicator mean?
A duplicate IP address has been detected.