Brand:

Veeder-Root EMR4 Electronic Meter Register

Description

Electronic register with retrofit kits for common fuel meter makes

The Veeder-Root EMR4 is an electronic meter register for fuel meters. A display head shows the delivered quantity on an anti-fog, nitrogen-purged, ultra-bright LED back-lit display, and an interconnect box (IB) connects display heads, pulsers, printers and solenoid valves. A system can have two display heads per interconnect box and up to 32 display heads (16 interconnect boxes) can be daisy-chained into one network, which can share a common printer.

The datasheet is a hardware list: it names display heads in English, French and Spanish, remote display heads, UL/cUL and ATEX/IECEx interconnect boxes, installation and retrofit kits for specific meter makes, remote pulser kits, the DataLink serial kit and accessories such as printers, temperature probes and valve kits.

Technical specifications

Values come from the Veeder-Root EMR4 datasheet (P/N 577014-456 Rev. B, 2024).

Parameter Specification
Manufacturer / product Veeder-Root EMR4 Electronic Meter Register
Display heads 0845593-001 English; 0845592-001 French; 0845594-001 Spanish; remote display heads -002 in the same languages
Interconnect box 0845790-001 UL/cUL; 0845760-001 ATEX/IECEx
Network Up to 2 display heads per interconnect box; up to 32 display heads (16 IBs) daisy-chained; shared printer
Installation kits (examples) 0845900-304 Tokheim, Daniels, Energy Flow Systems (Donovan); 0845900-305 Smith Meter, Satam, Avery Hardoll, Petrol Instruments, Alfons Haar; 0845900-306 LC, TCS, SAMPI, Tuthill; 0845900-327 Brooks / Brodie; Neptune and Liquatech kits -308, -309, -310
Retrofit kits (examples) 0845900-004, -005, -006, -008, -009, -010, -027 for the same meter groups
Remote pulser kits 0845900-504 to -506 (UL); 0845900-552 to -554 (ATEX)
Communication DataLink (0845900-038 direct serial kit), pulse output, RS-232 (OBC protocol)
Display Anti-fog (nitrogen-purged), ultra-bright LED white back-lit display
Operating temperature Display head -40 to +140 °F (-40 to +60 °C); interconnect box -13 to +104 °F (-25 to +40 °C)
Interconnect box power 10 to 28 V DC, 5 A (see EMR4 Application Guide for power conditioning)
Installation location (IB) NEMA 4 or indoors
Security Programmable security code for dispensing; compliant with WELMEC 7.2 software guidelines
Safety approvals UL/cUL, ATEX/IECEx, ANZEx, INMETRO and PESO certified
Metrological certifications NMO and NMi OIML R117; NMI; Measurement Canada; NTEP (NIST Handbook 44 and NCWM Publication 14)

Accessories and spares

The accessory list includes an Epson slip printer kit (0845900-020), slip printer (0845900-066) and roll printer (0845900-067) with 10 ft and 35 ft cables, a temperature probe kit (0845900-302) and thermowell (0331373-001), a 4-wire armoured cable, a 2 in NPT two-stage 12 VDC solenoid valve kit, a diode suppression kit, a 3-way solenoid valve kit for US propane, right-side and left-side keypads, an RS-232 cable and an emergency stop switch.

The register is described in a separate EMR4 Application Guide (577014-339), which the datasheet references for power conditioning and system design.

What to confirm before ordering

  • Meter make and model, to choose the installation or retrofit kit (Tokheim, Smith Meter, Neptune, Brooks and others are listed).
  • Language of the display head, and fixed or remote display.
  • Hazardous-area requirement: UL/cUL or ATEX/IECEx interconnect box and pulser kits.
  • Whether temperature compensation, a printer or DataLink communication is required, and the legal-metrology approval (for example OIML R117) your authority needs.

Documents and quotation

The Veeder-Root EMR4 datasheet is attached to this page as a PDF with the full hardware list. Send us the meter make, quantity of display heads and the approvals needed and we will prepare a quotation. Seven Star LLC is an independent supplier in Muscat; price and lead time are confirmed per RFQ. Related range: flowmeters.

Datasheets & Documents
  • PDF Datasheet Veeder-Root EMR4 Electronic Meter Register datasheet and hardware list (P/N 577014-456 Rev. B) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Veeder-Root is an American supplier of automatic tank gauging and fuel management systems for service stations and fuel depots. The company was formed in May 1928 by the merger of Curtis Veeder's Hartford counter business, started in 1895, with the Root company of Bristol, Connecticut. A counter fitted to a gasoline pump in the early 1930s took Veeder-Root into the petroleum industry. Today it is part of Gilbarco Veeder-Root, a Vontier company.

Seven Star LLC is an independent supplier in Muscat. We list Veeder-Root consoles, probes and sensors from the maker's published datasheets for fuel stations, depots and airports in Oman and the GCC.

Veeder-Root company profile

Founded May 1928, Connecticut, USA, by the merger of Veeder Manufacturing (1895) and the Root company
Headquarters Simsbury, Connecticut, USA
Ownership Vontier, through Gilbarco Veeder-Root
Installed base Tank monitoring in more than 500,000 underground storage tanks, according to the company
Product families TLS-450PLUS and TLS4 automatic tank gauges, Mag Plus magnetostrictive probes, leak and interstitial sensors, line leak detectors, submersible turbine pumps (Red Jacket) and fuel management software

Milestones

  • 1895: Curtis Veeder starts Veeder Manufacturing in Hartford.
  • 1928: Veeder and Root merge to form Veeder-Root.
  • Early 1930s: Veeder-Root counters are fitted to gasoline pumps, starting its petroleum business.

Veeder-Root product series

Tank gauge consoles include the TLS4 and the non-expandable TLS4B, the TLS-450PLUS and the legacy TLS-350PLUS. Mag Plus in-tank probes are offered for gasoline and diesel, jet fuel, LPG and light and heavy oil, and Mag-FLEX probes cover tall tanks. Leak detection sensors include the discriminating containment sump sensor 0794380-352 and the interstitial sensor 0794390-420 for double-wall steel tanks. The EMR4 electronic meter register is used on fuel delivery trucks.

Where Veeder-Root products are used

Petrol stations, fuel depots, airports and fleet fuelling sites, where the system measures product level, water and temperature in underground and aboveground tanks, monitors sumps and interstitial spaces and supports inventory reconciliation and leak tests.

Veeder-Root products we list

Family Examples
Level Instrumentation Discriminating Containment Sump Sensor 0…, Interstitial Sensor for Steel Tanks 0794…, Mag Plus In-Tank Probe for Gasoline and…, Mag Plus In-Tank Probe for Jet Fuel, Mag Plus In-Tank Probe for Light and Hea…, Mag Plus In-Tank Probe for LPG, Mag-FLEX In-Tank Probes for Tall Tanks, TLS-350PLUS Automatic Tank Gauge (Legacy… and 3 more

Ordering Veeder-Root products: what we need

Send the console model and the modules installed, the number of tanks, the product in each tank, the tank type and diameter for probe length, and the sensors required. Where a model is discontinued, we say so on the product page and confirm the successor before quoting.

Facts checked against Veeder-Root's company overview and published company histories, October 2026.

Frequently Asked Questions

What is the EMR4?
An electronic meter register for fuel meters, with a display head, interconnect box and retrofit kits for several meter makes.
How many display heads can one system have?
Two per interconnect box, and up to 32 display heads when 16 interconnect boxes are daisy-chained.
Which metrological approvals are listed?
OIML R117 (NMO, NMi, NMI), Measurement Canada and NTEP.
Does it have hazardous-area versions?
Yes. An ATEX/IECEx interconnect box (0845760-001) and ATEX pulser kits are listed.
What communications does it offer?
DataLink, pulse output and RS-232 in the OBC protocol.