Brand:

Veeder-Root Discriminating Containment Sump Sensor 0794380-352

Description

Sensor that tells fuel from water in a containment sump

The Veeder-Root Discriminating Containment Sump Sensor, part number 0794380-352, is installed in a containment sump area and detects the presence of hydrocarbons and also differentiates them from other liquids such as water. It reports to a Veeder-Root tank gauge console, so a sump that fills with water produces a different alarm from one that has a fuel leak.

It is a discriminating level-sensing sensor with a product-permeable element and a reed switch and float. A permeable material saturated with fuel raises a fuel alarm, while a float reports water at two levels: low liquid at 1.35 in and high liquid at 12.28 in. The sensor is 22.1 in tall and 2.2 in in diameter and is supplied with a 12 ft cable.

Technical specifications

Values come from the Veeder-Root sensor specification P/N 577013-750-02 Rev. AF (2025).

Parameter Specification
Manufacturer / part number Veeder-Root 0794380-352 Discriminating Containment Sump Sensor
Sensor type Discriminating level sensing
Operating principle Product permeable element with reed switch and float
Product activation height Gas (fuel): 0.125 in (3.175 mm)
Water activation heights Low: 1.35 in (3.4 cm); high: 12.28 in (31.19 cm)
Alarm states Normal (no liquid); low liquid; high liquid; fuel alarm (permeable material saturated with fuel); sensor out (not communicating)
Operating temperature +32 to +140 °F (0 to +60 °C)
Dimensions 22.1 in (56.1 cm) high; 2.2 in (5.6 cm) diameter
Standard cable length 12 ft (3.66 m)
Installation kit 0330020-012 Universal Sensor Mounting Kit (sold separately)
Console and software TLS-450PLUS 6.A or higher; TLS-450 4.A or higher; TLS4 / TLS4i / TLS4B / TLS4c 6.A or higher; TLS-350/R/PLUS 124/324 or higher; TLS-350J; TLS-300i
Interface modules USM 0332812-001 (16 inputs); USIOM-AC 0330020-750 (12) and -751 (6); interstitial sensor interface module 0329358-001 (8 inputs); 4 probe / 4 sensor module 0329356-003; 4 probe / 8 sensor module 0330230-001
Manufacturer warranty 1 year parts and labor with system; 1 year parts only when purchased separately

Where and how it is mounted

The datasheet’s example installation shows the sensor beside the submersible pump in a containment sump, with an optional universal mounting kit (brackets and clamp), a weatherproof junction box, a seal-off and rigid conduit to the console, and a cord grip supplied with the cable. The sheet also lists typical locations for Veeder-Root sensors in general, such as dispenser pans, spill containment, STP sumps, annular space, monitoring wells and oil/water separator tanks, so check the compatibility matrix in the datasheet for the fuel and location you need.

Fuel compatibility is shown as a matrix in the datasheet against gas, diesel, kerosene, jet fuel, aviation gas, ethanol blends, biodiesel, green diesel, DEF, waste oil and motor oil; the matrix is not reproduced here, so please refer to the PDF for the product you will monitor.

What to confirm before ordering

  • Console model and software version, and a free sensor input or interface module.
  • Sump depth and cable run: the standard cable is 12 ft, so confirm distance to the junction box.
  • Whether discrimination between fuel and water is needed; a non-discriminating sensor is a different part.
  • Fuel and liquid type against the datasheet’s compatibility matrix.

Installing the sensor in the containment sump

Before installation, clean the sump of water, fuel residue and debris so that the sensor starts in its normal state, and check the sump for cracks or failed penetration fittings that would let groundwater in. Place the sensor at the lowest point of the sump, standing upright and resting on the floor, so that small amounts of liquid reach it first. Keep it clear of piping, the pump and cables so that it cannot be knocked over during maintenance. Route the cable to the junction box with enough slack for removal and inspection, make the splice according to the Veeder-Root installation instructions, and keep the connection dry and sealed. Wiring between the junction box and the console must follow the hazardous-area rules that apply to the forecourt or fuel depot.

Commissioning with the tank gauge console

Once the sensor is wired, program it on the console with its location and type, then confirm that the console shows the normal state. Where site procedures allow, test the water alarms by raising the water level in a controlled way, and confirm that the low and high liquid alarms appear with the correct sump name. Make sure the alarm messages reach the people who must respond, whether that is the station manager, the maintenance contractor or a remote monitoring service, and record the results in the site compliance file.

Responding to alarms

A water alarm usually points to rainwater or groundwater entering the sump, while a fuel alarm points to a leak from piping, fittings or the pump. Treat every fuel alarm as a possible leak, inspect the sump and follow the site emergency procedure. After a fuel alarm, the sensor should be checked and serviced or replaced according to the manufacturer instructions before the system is returned to normal monitoring.

Maintenance in Omani and GCC fuel stations

Fuel stations and depots in Oman and the wider Gulf face strong sun, high ground temperatures, sand and occasional heavy rain. Sand and dust that enter sumps during maintenance or through loose covers build up around the sensor, so include sump cleaning in routine inspections and keep sump lids properly closed. The operating range of the sensor ends at +60 °C; sumps exposed to direct sun with poorly fitting covers should be checked to make sure conditions inside stay within this range. After heavy rain or flooding, inspect sumps for water and check that the alarms behaved as expected. Annual or periodic inspections required by the fuel company or local authority are a good time to review the sensor, its cable and the junction box together.

Documents and quotation

The Veeder-Root specification sheet for the 0794380-352 sensor is attached to this page as a PDF. Send us the console, sump details and fuel and we will prepare a quotation. Seven Star LLC is an independent supplier in Muscat; price and lead time are confirmed per RFQ. This sensor is filed under our level instrumentation category, the nearest leaf for fuel and liquid detection.

Datasheets & Documents
  • PDF Datasheet Veeder-Root Discriminating Containment Sump Sensor specification (P/N 577013-750-02 Rev. AF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Veeder-Root is an American supplier of automatic tank gauging and fuel management systems for service stations and fuel depots. The company was formed in May 1928 by the merger of Curtis Veeder's Hartford counter business, started in 1895, with the Root company of Bristol, Connecticut. A counter fitted to a gasoline pump in the early 1930s took Veeder-Root into the petroleum industry. Today it is part of Gilbarco Veeder-Root, a Vontier company.

Seven Star LLC is an independent supplier in Muscat. We list Veeder-Root consoles, probes and sensors from the maker's published datasheets for fuel stations, depots and airports in Oman and the GCC.

Veeder-Root company profile

Founded May 1928, Connecticut, USA, by the merger of Veeder Manufacturing (1895) and the Root company
Headquarters Simsbury, Connecticut, USA
Ownership Vontier, through Gilbarco Veeder-Root
Installed base Tank monitoring in more than 500,000 underground storage tanks, according to the company
Product families TLS-450PLUS and TLS4 automatic tank gauges, Mag Plus magnetostrictive probes, leak and interstitial sensors, line leak detectors, submersible turbine pumps (Red Jacket) and fuel management software

Milestones

  • 1895: Curtis Veeder starts Veeder Manufacturing in Hartford.
  • 1928: Veeder and Root merge to form Veeder-Root.
  • Early 1930s: Veeder-Root counters are fitted to gasoline pumps, starting its petroleum business.

Veeder-Root product series

Tank gauge consoles include the TLS4 and the non-expandable TLS4B, the TLS-450PLUS and the legacy TLS-350PLUS. Mag Plus in-tank probes are offered for gasoline and diesel, jet fuel, LPG and light and heavy oil, and Mag-FLEX probes cover tall tanks. Leak detection sensors include the discriminating containment sump sensor 0794380-352 and the interstitial sensor 0794390-420 for double-wall steel tanks. The EMR4 electronic meter register is used on fuel delivery trucks.

Where Veeder-Root products are used

Petrol stations, fuel depots, airports and fleet fuelling sites, where the system measures product level, water and temperature in underground and aboveground tanks, monitors sumps and interstitial spaces and supports inventory reconciliation and leak tests.

Veeder-Root products we list

Family Examples
Level Instrumentation Discriminating Containment Sump Sensor 0…, Interstitial Sensor for Steel Tanks 0794…, Mag Plus In-Tank Probe for Gasoline and…, Mag Plus In-Tank Probe for Jet Fuel, Mag Plus In-Tank Probe for Light and Hea…, Mag Plus In-Tank Probe for LPG, Mag-FLEX In-Tank Probes for Tall Tanks, TLS-350PLUS Automatic Tank Gauge (Legacy… and 3 more

Ordering Veeder-Root products: what we need

Send the console model and the modules installed, the number of tanks, the product in each tank, the tank type and diameter for probe length, and the sensors required. Where a model is discontinued, we say so on the product page and confirm the successor before quoting.

Facts checked against Veeder-Root's company overview and published company histories, October 2026.

Frequently Asked Questions

What does the 0794380-352 sensor detect?
Hydrocarbons in a containment sump, and it distinguishes them from other liquids such as water.
What alarms does it give?
Normal, low liquid, high liquid, fuel alarm and sensor out.
At what height does it detect water?
Low liquid at 1.35 in (3.4 cm) and high liquid at 12.28 in (31.19 cm).
How long is the cable?
The standard cable length is 12 ft (3.66 m).
Which consoles support it?
TLS-450PLUS, TLS4 series, TLS-350 series and TLS-300i, with the minimum software versions listed in the datasheet.