Brand:

Minimax Inveron Hazard Management System Software

Description

One operator interface for fire, extinguishing and hazard messages

The Minimax Inveron hazard management system displays information from different systems clearly on a single user interface. For spacious and complex production or building structures, responsible persons see the relevant data from fire detection, extinguishing and other hazard detection systems at once and can decide correctly under stress.

All messages and events are brought together automatically in a graphic interface. The status of control points can be shown graphically, as text or as an animation, with threshold messages above and below limits displayed in real time. Several locations of one company can be included in one overall system, with authorisation and data supply controlled centrally so that each location sees only its own information.

Technical specifications

Parameter Specification
System type Software and hardware hazard management system
Monitoring points Several thousand monitoring points
Hardware needed PC and/or server, desktop and large-format screens; cameras and PLC controllers if required
Interfaces Proprietary protocol to Minimax fire detection control panels; open standards OPC, Modbus, Profibus, BACnet
Other systems Gas detection panels via Modbus, CCTV verification, intrusion detection, gate control; PLC for heating, ventilation or fire doors
Notification SMS or e-mail; iOS and Android app
Graphics Vector graphics (for example AutoCAD), pictures, video or camera streams; up to five animated graphics per event
Documentation All events logged automatically; PDF report from message handling; archive limited only by hard drive size
Fire department route cards Automatic generation and printing from a central database

Integration, alarm handling and documentation

Inveron integrates detection points of many fire detection and extinguishing systems, so it can stay in use for the long term even if fire detection manufacturers or systems change. Locations anywhere can be monitored from a central position, and messages can be switched to another location if a security point is not manned.

Action texts tell the operator which steps to start, and individual technical drawings of the detectors can be shown for each event. Signals are forwarded to the permanently attended place, other workplaces, service staff or an on-call service. In the open edit version the operator interface can be changed by the user at any time. For fire services, route cards from the fire detection panel to the activated detector can be generated and printed automatically when an alarm occurs.

What to confirm before ordering

Inveron is configured per customer, so a quotation needs the number of locations and monitoring points, the existing fire detection and extinguishing systems and their interfaces, the screens and workstations wanted, and any camera or PLC integration. Inveron can also be linked to Minimax panel networks through Clunid Connect.

Documents and quotation

The Minimax Inveron brochure is attached. Seven Star LLC is an independent supplier in Muscat; the software scope and licensing are confirmed with Minimax before a price is given. Related items are in Logic Controllers.

Datasheets & Documents
  • PDF Brochure Minimax Inveron Hazard Management System Brochure Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fire detection and extinguishing systems for industrial plants, data centers and logistics buildings are the business of Minimax, based in Bad Oldesloe, Germany. Seven Star LLC is an independent supplier in Oman and lists Minimax fire control panels, detectors, a deluge valve set and the MxSysCon fire control configuration software, supplied with its licence dongle. We also take inquiries for Minimax fire protection components and spare parts identified by part number.

Minimax systems the software and parts belong to

The manufacturer's program covers fire detection and extinguishing control panels of the FMZ family and HELIOS aspirating smoke detectors. On the extinguishing side it builds deluge and other water-based systems, Minifog water mist, Oxeo inert gas and carbon dioxide systems, and spark extinguishing. Panel configuration software is tied to a specific panel generation. We did not find the name MxSysCon in the manufacturer's public documents, so the software version has to be checked against your panel type.

Ordering Minimax items: what we need

Send the Minimax part number, the type and firmware version of the control panel, and a photo of the panel label. For detectors, nozzles or valves, add the nameplate data and the approval the project specifies. Minimax systems are engineered per site, so a component is only correct when it matches the original system documents. We check that match for buyers across the GCC before the order is placed.

Frequently Asked Questions

What does Inveron display?
It displays messages and events from fire detection, extinguishing and other hazard detection systems on one clear user interface.
Which interfaces does it support?
A proprietary protocol to Minimax fire panels, plus OPC, Modbus, Profibus and BACnet open standard interfaces.
Can it monitor several sites?
Yes, several locations of one company can be incorporated into one system, each seeing only the information intended for it.
How are alarms forwarded?
By SMS or e-mail, and an iOS or Android app gives access to messages.
Does it keep records?
All status changes, messages and user inputs are logged automatically, and PDF reports can be created.