- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Isolator & Barrier
- Automation Software
- Machine Vision
- Robotics
Brand: Druck
Druck PDCR 1800 / PTX 1800 Titanium Submersible Level Pressure Sensor
Description
A fully submersible titanium sensor for hydrostatic level measurement
The Druck PDCR 1800 (mV output) and PTX 1800 (4 to 20 mA output) are fully submersible titanium pressure sensors for measuring hydrostatic liquid level in boreholes, rivers, canals, reservoirs, sewage works, tanks and seawater. The body is a fully welded 17.5 mm diameter titanium tube, and the sensing element is a micromachined silicon element sealed in a titanium pressure module and isolated from the media.
The cable has a Kevlar strain cord and is rated IP68 for indefinite immersion in 700 mH2O. Two cable materials are offered: vented polyurethane (1830) and vented Hytrel 6108 (1840) for hydrocarbon resistance. Cable lengths are specified in 1 m steps, to 500 m for the PTX 1800 and to 100 m for the PDCR 1800, with 1 m datum marks for fast alignment below ground level.
Accuracy is plus or minus 0.1% FS best straight line, with an improved option, and ranges run from 0.75 to 600 mH2O.
Technical specifications
| Parameter | Specification |
|---|---|
| Output | PDCR 1800: mV (25 mV for 0.75 mH2O, 50 mV for 1.5 and 3.5 mH2O, 100 mV for 7 mH2O and above); PTX 1800: 4 to 20 mA, 2-wire |
| Pressure ranges | 0.75 to 600 mH2O, gauge or absolute (PDCR 1800 listed ranges 0.75, 1.5, 3.5, 7, 10, 15, 20, 35, 50, 70, 100, 150, 200, 350, 600 mH2O); PTX 1800 any zero-based range |
| Accuracy | Standard +/-0.1% FS BSL maximum; Option D +/-0.06% FS BSL (+/-0.08% FS for 1 mH2O and below) |
| Long-term stability | +/-0.1% FS per annum |
| Excitation | PDCR 1800: 10 V at 5 mA nominal; PTX 1800: 9 to 30 VDC |
| Operating temperature | -20 to 60 degrees C; compensated -2 to 30 degrees C |
| Temperature error band | +/-0.3% FS for 3.5 mH2O and above; +/-0.6% FS for ranges below 3.5 mH2O |
| Overpressure | 8 x FS up to 1.5 mH2O; 6 x FS up to 3.5 mH2O; 4 x FS above (1400 mH2O maximum) |
| Ingress protection | IP68 to 700 mH2O |
| Media compatibility | Fluids compatible with titanium, acetal nose cone and polyurethane or Hytrel 6108 cable; not for oxygen above 21% or strong oxidisers |
| Intrinsic safety (option B) | ATEX, IECEx and UKEX Ex ia IIC T4 Ga for IS barrier systems; FM US option B1 |
| Pressure connection | Radial holed M14 x 1.5 male with acetal nose cone; option C welded G1/4, 1/4 NPT, M12 x 1 and other connections (PTX 1800) |
| Dimensions | Diameter 17.5 mm; length about 109 mm (PDCR 1800) and 185 mm (PTX 1800) |
Ordering code and accessories
The model code is PDCR 18 or PTX 18 followed by a cable type digit (3 polyurethane or 4 Hytrel), a lightning surge arrestor digit (0 not required, 5 fitted, PTX versions only), then pressure range and units, options (B intrinsically safe, B1 FM US intrinsically safe, C alternative pressure connection for PTX, D improved accuracy), the cable length and accessories ordered as separate items.
Accessories named in the datasheet are the STE moisture-proof sensor termination enclosure, slimline and short sink weights, a cable clamp system, rotatable calibration adapters for G1/8 or 1/8 NPT and an accessory pack that contains the STE box, sink weight, cable clamp and direct calibration adapter. The related Druck UNIK 5000 platform is listed on this site.
What to confirm before ordering
Select the range in metres of water with margin for the maximum depth, the output type (mV or 4 to 20 mA), the cable material for the liquid, the cable length including the run to the junction box, and whether intrinsic safety, a lightning arrestor or the improved accuracy option is needed. Avoid oxygen-rich media.
How the Druck PDCR 1800 works
The sensor sits under the liquid on the end of a cable. The liquid pressure acts on a diaphragm in the titanium nose. A silicon element turns the pressure into a signal. The cable has a vent tube so the sensor reads the pressure of the liquid above the air pressure. The signal goes up the cable to the logger or the transmitter.
Where the PDCR 1800 is used
- Boreholes
- Rivers and canals
- Reservoirs
- Sewage works
- Tanks and seawater
Selection checklist for the PDCR 1800
- Output: mV or 4 to 20 mA
- Range from 0.75 to 600 mH2O
- Accuracy option
- Cable length
- Cable material, polyurethane or Hytrel
- Pressure connection
- Liquid compatibility
- Intrinsic safety need
Installation, commissioning and maintenance notes for the PDCR 1800
Lower the sensor on its cable to the depth wanted. Use the datum marks at every meter to set the depth. Keep the vent tube dry at the top end. Set the zero with the sensor in the liquid. Rinse the nose cone when it is lifted out.
Requesting a quotation for the Druck PDCR 1800
Please send the range, the output, the cable length and the liquid. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
PDCR 1800 body
The body is a welded titanium tube with a diameter of 17.5 mm.
PDCR 1800 output
The PDCR 1800 gives a mV output and the PTX 1800 gives 4 to 20 mA.
PDCR 1800 range
The range runs from 0.75 to 600 mH2O, gauge or absolute.
PDCR 1800 accuracy
The accuracy is plus or minus 0.1 percent of full scale, and 0.06 percent with option D.
PDCR 1800 stability
The long-term stability is plus or minus 0.1 percent per year.
PDCR 1800 excitation
The PDCR 1800 runs on 10 V and the PTX 1800 on 9 to 30 VDC.
PDCR 1800 cable
The cable is rated IP68 and the length is chosen in 1 m steps.
PDCR 1800 temperature
The operating range is minus 20 to plus 60 degrees C.
PDCR 1800 connection
The standard connection is M14 x 1.5 male with an acetal nose cone.
Sensor records for the PDCR 1800
Record the zero reading, the cable length and the date of each check.
Choosing the right PDCR 1800 cable
Choose the Hytrel cable where hydrocarbons are in the liquid.
Documents and quotation
The attached file is the five-page Druck 1800 series datasheet dated March 2026. Send the full code, range and cable length to Seven Star LLC for a quotation. Compare other sensors in Pressure Instrumentation.
Datasheets & Documents
- Datasheet Druck 1800 series (PDCR 1800 / PTX 1800) datasheet (EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Druck is a British maker of pressure sensors and pressure calibration instruments, founded in 1972 in Leicester by Mike Bertioli and John Salmon to commercialise silicon piezoresistive pressure sensors; the name is the German word for pressure. Druck joined GE in 2002, later became a Baker Hughes business, and since 1 January 2026 has been part of Crane Company.
Seven Star LLC is an independent supplier in Muscat. We list Druck calibration equipment and pressure sensors for instrument technicians, calibration labs and offshore users in Oman and the GCC.
Druck company profile
| Founded | 1972, Leicester, England, by Mike Bertioli and John Salmon |
|---|---|
| Name | From the German word Druck, meaning pressure |
| Key technology | Silicon piezoresistive pressure sensing |
| Ownership | Crane Company since 1 January 2026, as part of the Precision Sensors & Instrumentation business bought from Baker Hughes |
| Product families | DPI 620 Genii and DPI 611/612 portable calibrators, PACE pressure controllers, UNIK 5000 pressure sensors, ADTS air data test sets, hand pumps and pressure stations |
Milestones
- 1972: Druck is founded in Leicester.
- 2002: Druck becomes part of GE.
- 2017: With GE's oil and gas business, Druck becomes a Baker Hughes business.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Druck.
Druck product series
Calibration equipment includes the DPI 611 hand-held pressure calibrator, the DPI 880 multi-function calibrator for electrical, temperature and pressure, the PV624 portable automatic pressure controller and the PACE5000 and PACE6000 modular bench pressure controllers. Hand pumps include the PV211 pneumatic pump for 40 bar, the PV212 hydraulic pump for 700 and 1000 bar and the PV411A four-in-one pressure and vacuum pump.
Sensors and transmitters include the PDCR 1800 and PTX 1800 titanium submersible level sensors, the PTX300 subsea transmitter and PTX400 subsea wellhead pressure and temperature transmitter, the UNIK 5600 and 5700 marine-approved transmitters and the RPS 8000 and DPS 8000 resonant pressure sensors for high accuracy.
Where Druck products are used
Field and workshop calibration of pressure transmitters, gauges, switches and safety valves, well and tank level measurement, subsea and wellhead monitoring, and high-accuracy reference measurement.
Druck products we list
Ordering Druck products: what we need
Send the model, pressure range and type (gauge, absolute or differential), accuracy class, pressure connection, electrical connection and output, and any options such as HART, intrinsic safety or accessories. For calibrators, state the modules and test leads required.
Facts checked against Baker Hughes' Druck history page and Crane Company's January 2026 completion release, October 2026.
Browse Druck products by category: Portable Test & Measurement, Pressure Instrumentation.
Related products
Frequently Asked Questions
The PDCR 1800 has a mV output; the PTX 1800 is a 2-wire 4 to 20 mA transmitter.
0.75 to 600 mH2O, gauge or absolute, with other units such as bar or psi on request.
Standard accuracy is +/-0.1% FS BSL; option D improves it to +/-0.06% FS.
Vented polyurethane (1830) or hydrocarbon-resistant Hytrel 6108 (1840), in 1 m steps.
Yes, option B is ATEX, IECEx and UKEX certified, and option B1 is FM US certified.

Reviews
There are no reviews yet.