- Automation & ControlView all 2,954 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Magnetrol
Magnetrol Thermatel TD1/TD2 Thermal Dispersion Flow and Level Switch
Description
Overview
The Magnetrol Thermatel TD1/TD2 is a family of thermal dispersion switches that detect flow, level or interface without any moving parts. Magnetrol designed the TD1 as a basic switch and the TD2 as an advanced version with more diagnostics and indication, and both provide continuous diagnostics with fault indication, temperature compensation, narrow hysteresis and fast response. The same switch can be used for liquid flow, gas flow, high or low level and interface detection, which makes the Magnetrol Thermatel TD1/TD2 one of the most versatile point instruments in a plant.
Seven Star LLC supplies the Magnetrol Thermatel TD1/TD2 to refineries, power stations, chemical plants and water utilities across the Sultanate of Oman and the GCC. Our Muscat engineers help customers choose the probe tip, material and insertion length, and confirm whether a TD1 or a TD2 suits the duty and the control room requirements.
Operating Principle
The Magnetrol Thermatel TD1/TD2 relies on thermal dispersion. The sensor has two RTD elements: one measures the process temperature and acts as a reference, while the other is heated to a temperature above it. The electronics compare the two. The temperature difference is greatest in dry air and falls when the heated element is cooled by a liquid, and it falls further as the flow velocity rises. The set point is adjusted for the switch to alarm at the chosen temperature difference, and the relay changes state when that value is reached.
Because the switch is self-heated, it can use the same principle for flow and level. In flow service it sees heat carried away by moving media, and in level or interface service it sees the difference in thermal conductivity between air, foam, oil and water. Temperature compensation prevents the set point from drifting when the process temperature changes, and a factory calibration can be ordered at a specified flow rate. Fault detection monitors the sensor signal continuously and de-energises the relay if the signal goes out of range.
Engineering Design of the Magnetrol Thermatel TD1/TD2
The Magnetrol Thermatel TD1/TD2 is built with probes in all-welded construction using 316/316L stainless steel, Hastelloy C or Monel. Two tip designs are offered: the twin tip, preferred for higher pressures up to 3000 psig, corrosion-resistant materials and gas flow, and the spherical tip, recommended for high viscosity, full vacuum and applications where build-up can occur. A high temperature/high pressure sensor reaches +850 °F (+454 °C) and 6000 psi, a mini sensor fits tees of 1/2, 3/4 and 1 inch, and a low flow body handles very small flows.
The electronics are housed in cast aluminium (A356 with less than 0.2 percent copper) or stainless steel. The TD2 can be supplied with remote electronics up to 500 feet (150 m) from the probe, and the TD1 and TD2 are offered with hot tap retractable assemblies and NACE construction. Probe insertion lengths run from 2 to 130 inches for spherical and twin-tip probes, and the process connection is defined in the part number.
Key Features
The Magnetrol Thermatel TD1/TD2 switches combine simplicity with strong diagnostics. Key features of the Magnetrol Thermatel TD1/TD2 include:
- No moving parts, with excellent low flow sensitivity and low hysteresis between alarm and reset points.
- Temperature compensation for a repeatable alarm under varying process temperatures, with repeatability better than 1 percent.
- Continuous diagnostics that detect sensor faults and de-energise the relay, with the TD2 also driving the mA output to 3.6 or 22 mA.
- Non-linear mA output on the TD2 for trending, diagnostics and flow or level indication.
- Set point ranges of 0.01 to 5 feet per second for water and 0.1 to 500 standard feet per second for air.
- Adjustable time delay of 0 to 100 seconds on the TD2, with a hermetically sealed relay option.
- Process temperature range of -100 to +400 °F, with a high-temperature version to +850 °F.
- Safe failure fraction of 69.3 percent for the TD1 and 73 percent for the TD2.
Industrial Applications
The Magnetrol Thermatel TD1/TD2 is widely used for pump protection, where a no-flow or low-flow condition must trip a pump before damage occurs, for cooling air or water flow monitoring on heat-generating equipment, for relief valve leakage detection and for lubrication systems. In Oman, cooling-water loops in power and desalination plants, seal-water lines on pumps and compressors, and chemical feed pumps in water treatment all call for a robust flow alarm. The switch is also used for oil and water interface detection and liquid and foam detection, where its adjustable sensitivity is useful. Alternative technologies for level duty include the VEGASWING 61 and the ABB RS85 vibrating fork switch.
Seven Star LLC supplies the Magnetrol Thermatel TD1/TD2 on request, with engineering support in Muscat, to contractors and operators in the Sohar and Salalah economic zones. For clean level applications where thermal sensing is unnecessary, we can also supply the ABB A75 RF capacitance switch, and our team will advise which technology gives the best reliability for your fluid.
Technical Specifications
The table lists the main data of the Magnetrol Thermatel TD1/TD2 from the Magnetrol datasheet. Probe style and process connection are defined by the part number.
| Parameter | Specification |
|---|---|
| Model | Magnetrol Thermatel TD1/TD2 thermal dispersion switch |
| Supply | TD1: 19.2 to 28.8 VDC; TD2: 19.2 to 28.8 VDC or 100 to 264 VAC, 50-60 Hz |
| Output relay | DPDT, 8 A at 120/250 VAC; hermetically sealed relay option on TD2 |
| Sensor temperature | -100 to +400 °F (-73 to +204 °C); high-temperature -100 to +850 °F |
| Ambient (electronics) | -40 to +158 °F (-40 to +70 °C) |
| Response time | 1 to 10 seconds, typical |
| Repeatability | Less than 1% at constant temperature |
| Probe materials | 316/316L stainless steel, Hastelloy C, Monel |
| Pressure | Twin tip to 3000 psig; HTHP sensor to 6000 psi (410 bar) |
| Insertion length | 2 to 130 in (5 to 330 cm) |
| Enclosure | Cast aluminium A356 or stainless steel |
| Safe failure fraction | TD1 69.3%; TD2 73% |
Request a Quote for Magnetrol Thermatel TD1/TD2
Send your RFQ for the Magnetrol Thermatel TD1/TD2 to Seven Star LLC with the medium, pipe or vessel size, flow set point or level duty, temperature, pressure, power supply and the TD1 or TD2 preference. Our instrumentation division in Muscat will select the probe and electronics, confirm calibration options and provide the Magnetrol datasheet with the quotation. Seven Star LLC supplies Magnetrol equipment with manufacturer documentation and local engineering support across Oman and the GCC, so contact us today for the Magnetrol Thermatel TD1/TD2.
See also: Magnetrol 089-9126-002 Transducer Kit for Echotel 355, FM, Kynar, NPT; Magnetrol 004-5867-056 TG1 2 Inch Class 600 Hastelloy C Flange.
Datasheets & Documents
- Datasheet Magnetrol Thermatel TD1/TD2 Thermal Dispersion Flow Level Interface Switch Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol Thermatel TD1/TD2 Thermal Dispersion Flow
Answers from our engineering team on installation, compatibility and integration.
01How does the Magnetrol Thermatel TD1/TD2 detect flow?
The Magnetrol Thermatel TD1/TD2 uses two RTD elements, one as a reference and one heated above process temperature. Flowing media carries heat away from the heated element, so the temperature difference between the two falls as the flow rises, and the relay changes state at the set point.
02What is the difference between the TD1 and the TD2?
The TD1 is the basic switch with a 24 VDC supply and an 8 amp DPDT relay. The TD2 adds LED indication through a window, set point measurement, a mA output for diagnostics and trending, an optional hermetically sealed relay, adjustable time delay and a universal AC supply.
03Can the Magnetrol Thermatel TD1/TD2 be used for level and interface detection?
Yes. Because the sensor responds to the thermal conductivity of the media, it can detect high or low level, and interfaces such as liquid and foam or oil and water. It can be mounted vertically or horizontally.
04What temperatures can the Magnetrol Thermatel TD1/TD2 handle?
Standard sensors work from -100 to +400 °F (-73 to +204 °C), and the high-temperature sensor extends to +850 °F (+454 °C) at pressures up to 6000 psi (410 bar). A heat extension or remote electronics is needed above +250 °F (+120 °C).
05Does Seven Star LLC supply the Magnetrol Thermatel TD1/TD2 in Oman?
Seven Star LLC supplies the Magnetrol Thermatel TD1/TD2 with engineering support in Muscat for Oman and the GCC. Send the medium, line size, flow set point, temperature and pressure and we will quote the right probe and electronics.


















Reviews
There are no reviews yet.