Applied Analytics OMA Chlorine Analyzer

Description

Overview

The Applied Analytics OMA Chlorine Analyzer is a continuous process analyzer engineered to measure chlorine (Cl2) concentration in chlor-alkali and related chemical processes using dispersive UV-Vis absorbance spectrophotometry, isolating chlorine’s distinctive absorption signature from total sample absorbance via the Beer-Lambert law. Unlike wet-chemistry chlorine analyzers that consume reagents and require frequent maintenance, the OMA Chlorine Analyzer measures continuously and can monitor up to four chemical species concurrently, while a fiber-optic sample interface keeps the toxic, corrosive sample fluid physically outside the analyzer’s electronic enclosure.

With engineering support in Muscat, Seven Star LLC supplies the OMA Chlorine Analyzer to chlor-alkali and chemical processing facilities across Oman and the wider GCC, with manufacturer documentation and technical support with selection. Chemical producers in the Sultanate of Oman handling chlorine gas or chlorinated intermediates gain a regional partner for safe, compliant installation and ongoing technical support.

Operating Principle

The Applied Analytics OMA Chlorine Analyzer directs light from a pulsed xenon lamp with an approximately five-year average service life through the process sample and captures the full absorbance spectrum across 200-800 nm using a nova II UV-Vis diode-array spectrophotometer. Chlorine’s characteristic UV absorption signature is isolated computationally from the composite spectrum using Beer-Lambert law calculations, allowing the analyzer to report chlorine concentration accurately even when other absorbing species, such as nitrogen trichloride or vanadium compounds in titanium tetrachloride streams, are present in the same sample.

Critically, the OMA Chlorine Analyzer transmits the optical signal to and from the sample point via 600 micron-core fiber-optic cable, typically 1.8 meters in standard length, which means the sample flow cell can be mounted directly at the process point while the electronics, light source, and detector remain in a separate, safer location. This fiber-optic isolation is a major safety advantage for a toxic, corrosive gas like chlorine, removing the need to route a hazardous sample line into the analyzer’s own enclosure and reducing the consequence of any leak at the measurement point.

Engineering Design of the Applied Analytics OMA Chlorine Analyzer

The Applied Analytics OMA Chlorine Analyzer is built around a flow-cell and fiber-optic sample interface rated for sample pressures up to 206 bar (3000 psi) with the standard flow cell, and an operating temperature range of 0-35°C ambient as standard, extendable to -20 to 55°C for outdoor or extreme-climate installations. The core electronics and light source share the same rugged OMA enclosure family used across the Applied Analytics product line, with ATEX and Class I Division 1/2 hazardous-area variants available for chlor-alkali plant environments.

Power requirements are universal 85-264 VAC at 47-63 Hz, drawing only 45 watts, and the analyzer communicates through isolated 4-20 mA analog outputs with optional Modbus, HART, and RS-485 digital protocols for direct integration into a chlor-alkali plant’s distributed control system. Accuracy across the instrument’s range is rated at ±5 ppm for 0-100 ppm spans, ±2% of full scale or 5 ppm (whichever is larger) for 0-10,000 ppm spans, and ±2% of full scale at 0-100% concentration, giving plant chemists confidence in both trace-level and high-concentration chlorine measurement.

Key Features

The Applied Analytics OMA Chlorine Analyzer platform is engineered specifically around the safety and accuracy demands of continuous chlorine monitoring, and its key features include the following:

  • Continuous chlorine (Cl2) measurement using dispersive UV-Vis absorbance spectrophotometry, isolating the Cl2 signature via Beer-Lambert law calculation.
  • Simultaneous monitoring of up to four chemical species concurrently from a single optical measurement.
  • Fiber-optic sample isolation using 600 micron-core cable, keeping toxic, corrosive sample fluid outside the analyzer’s electronic enclosure.
  • Sample pressure rating up to 206 bar (3000 psi) with the standard flow cell, suiting high-pressure chlor-alkali process points.
  • Accuracy of ±5 ppm at low ranges and ±2% of full scale at higher concentrations, spanning trace detection through 0-100% measurement.
  • Operating temperature range of 0-35°C standard, extendable to -20 to 55°C for demanding outdoor climates.
  • A pulsed xenon light source with an average five-year lifespan, minimizing lamp-replacement downtime.
  • Isolated 4-20 mA analog outputs plus optional Modbus, HART, and RS-485 connectivity for DCS integration.

Industrial Applications

The Applied Analytics OMA Chlorine Analyzer is deployed across chlor-alkali production, chlorine gas handling, water treatment chlorination, and specialty chemical processes such as titanium tetrachloride and vinyl chloride monomer (VCM) manufacturing, wherever continuous chlorine monitoring is essential for both process control and personnel safety. Chemical processors across Oman and the GCC use this class of analyzer to maintain product quality specification while protecting operators from the corrosion resistance and toxicity risks inherent in chlorine gas handling.

Backed by genuine manufacturer documentation, Seven Star LLC distributes the OMA Chlorine Analyzer to chlor-alkali plants, water treatment operations, and specialty chemical producers throughout Oman and the GCC, including facilities in the Sohar and Salalah industrial and economic zones where chemical manufacturing capacity continues to grow. Regional customers gain access to genuine Applied Analytics hardware together with local calibration support, fiber-optic sample-interface spares, and application engineering, rather than depending solely on an overseas supply chain for a safety-critical chlorine measurement.

Technical Specifications

The table below summarizes the core specifications of the Applied Analytics OMA Chlorine Analyzer, and this is the standard configuration of the Applied Analytics OMA Chlorine Analyzer supplied for chlor-alkali service.

Parameter Specification
Model Applied Analytics OMA Chlorine Analyzer
Target Analyte Chlorine (Cl2); up to 4 species concurrently
Measurement Principle Dispersive UV-Vis absorbance spectrophotometry (Beer-Lambert law)
Detector nova II UV-Vis diode-array spectrophotometer
Wavelength Range 200-800 nm
Light Source Pulsed xenon lamp, ±5-year average lifespan
Sample Interface 600 µm core fiber optic, 1.8 m standard length
Sample Pressure Up to 206 bar (3000 psi) with standard flow cell
Operating Temperature 0-35°C standard (optional -20 to 55°C)
Accuracy ±5 ppm (0-100 ppm); ±2% FS or 5 ppm (0-10,000 ppm); ±2% FS (0-100%)
Outputs 1x isolated 4-20 mA per analyte; optional Modbus, HART, RS-485
Power 85-264 VAC, 47-63 Hz, 45 W

Request a Quote for Applied Analytics OMA Chlorine Analyzer

Chlor-alkali and chemical processing engineers across Oman and the GCC can request a formal quotation for the Applied Analytics OMA Chlorine Analyzer directly from Seven Star LLC, and can confirm current Applied Analytics OMA Chlorine Analyzer availability and lead time, with full technical datasheets on request and application-specific configuration guidance from our instrumentation division. Working closely with plant engineers in the region, Seven Star LLC supplies the OMA Chlorine Analyzer on request with local technical support, so contact our team today to specify the right chlorine monitoring solution for your process.

Browse the full Applied Analytics range or see more Gas Analyzer Systems products supplied by Seven Star LLC in Oman and the GCC.

Other Models in the Applied Analytics OMA Process Analyzers Range

Seven Star LLC supplies models from the Applied Analytics OMA Process Analyzers range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Applied Analytics OMA Odorant AnalyzerGas Analyzer SystemsView details
Applied Analytics OMA BTX AnalyzerGas Analyzer SystemsView details
Applied Analytics OMA Chlorine AnalyzerGas Analyzer SystemsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Applied Analytics OMA-300-CL2 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Applied Analytics, founded in 1994 and based in Burlington, USA, builds online process analyzers around one core instrument, the OMA, which reads a full absorbance spectrum of the sample instead of a single wavelength. Seven Star LLC lists Applied Analytics OMA analyzers for H2S, chlorine, BTX, odorant and multi-stream duty, and supplies them to gas plants, refineries and chemical sites in Oman as an independent supplier.

Applied Analytics OMA analyzers on this page

The manufacturer offers the OMA in three form factors: the wall-mounted OMA-300, the portable OMA-206P and the rackmount OMA-406R. The first two are listed here, with application-specific builds of the same platform:
  • OMA-300 H2S Analyzer and OMA-300 Multi-Stream Process Analyzer
  • OMA Chlorine, BTX and Odorant analyzers
  • OMA-300-InGaAs for near-infrared measurements
The company also makes the TLG-837 tail gas analyzer, a sulfur pit gas version of it, and sample conditioning systems designed for each project.

Where Applied Analytics analyzers are used

Typical duties are H2S in sour gas, acid gas and amine treating, sulfur recovery control, chlorine in chlor-alkali and water treatment, aromatics in hydrocarbon and wastewater streams, and mercaptan odorant in distribution gas. These are everyday measurements in GCC gas processing and refining.

Ordering an OMA analyzer: what we need

An OMA is configured for one stream, so the manufacturer needs process data before it can confirm a model. Send the stream composition with all components and their ranges, the analytes and measuring ranges, phase, pressure and temperature at the sample point, area classification, available utilities, required outputs and whether a sample conditioning system or shelter is part of the scope. For spares, send the analyzer serial number and the part description.

Frequently Asked Questions

How does the OMA Chlorine Analyzer keep toxic sample gas away from the electronics?
The OMA Chlorine Analyzer uses a 600 micron-core fiber-optic sample interface, typically 1.8 meters long, that transmits the optical signal to and from a remote flow cell. This lets the sample point stay at the process while the light source and detector electronics remain in a separate, safer location.
What sample pressures can the OMA Chlorine Analyzer handle?
The standard flow cell is rated to 206 bar (3000 psi), suiting most chlor-alkali and chlorine handling process points without additional pressure-reduction equipment ahead of the analyzer.
How accurate is the OMA Chlorine Analyzer across different concentration ranges?
Accuracy is rated at +/-5 ppm across a 0-100 ppm span, +/-2% of full scale or 5 ppm (whichever is larger) across a 0-10,000 ppm span, and +/-2% of full scale at 0-100% concentration, covering both trace-level compliance and high-concentration process control needs.
Can the OMA Chlorine Analyzer measure other chemicals alongside chlorine?
Yes. The analyzer can measure up to four chemical species concurrently, which is useful in processes such as titanium tetrachloride purification where chlorine, vanadium compounds, and other co-existing species need to be tracked from a single optical measurement.
Is Seven Star LLC an experienced supply partner for Applied Analytics products?
Yes. Seven Star LLC is an experienced supplier of Applied Analytics process analyzers in Oman and the GCC, supplying genuine equipment with calibration support and local technical support.